Function Descriptions

[4] IRIS Control

Auto Iris

The lens aperture is automatically controlled to correct the brightness of the average luminance value of the image.

Manual Iris

This fixes the lens aperture. The aperture position can be set to a range of 17 levels (1: close - 7: open) using the Manual IRIS Stop command.

EI ON

The light intensity can be controlled to a fixed level using an electronic shutter control.

Note: Executing the EI ON command sets the shutter speed mode to OFF.

EI OFF

This fixes the electronic shutter. Refer to the Shutter Speed Control on the next page regarding fixed values.

Iris Level

The target brightness can be configured to a range of 0 to 100.

[5] Shutter Speed Control

Prolonged Exposure Mode

The exposure time is a longer mode than 1 field. The field accumulation time can be configured from 1x to 32x.

However, this cannot be configured during the following conditions.

When SENSE UP is enabled.

When MOTION settings are enabled. When EI is ON.

Normal Mode

This is fixed to 1/60 (1/50).

High-Speed Shutter Mode

This can be configured from 1/60 to 1/10000.

Note 1) If flickering is noticeable in regions with a power supply frequency of 50Hz when using NTSC, switch to the High-Speed Shutter Mode (1/100).

Note 2) When switching to the Prolonged Exposure or High-Speed Shutter Mode, transmit the “Shutter Speed Set Mode” command after the “Shutter Long Direct” or “Shutter Short Direct” command.

SENSUP

If the illumination of the subject decreases, the Prolonged Exposure Control is automatically executed along with the AGC Control.

The maximum Field Accumulation Time can be configured to a range of 1x to 32x.

This cannot be configured during the following conditions.

When the MOTION settings are valid. When AGC is OFF.

In addition, the shutter speed mode is set to OFF.

[6] AGC Control

AGC ON

The gain is automatically controlled and light is fixed to a certain intensity.

The MAX gain of each mode of LOW/NORMAL/ MIDDLE/HIGH is roughly equivalent to the following gains.

AGC Gain (dB)

 

LOW

NORMAL

MIDDLE

HIGH

AUTO

9dB

12dB

15dB

COLOR

1.5dB

6dB

10.5dB

15dB

B/W

6dB

9dB

12dB

15dB

AGC OFF

This is the fixed gain mode. The gain value can be manually configured to 11 steps.*

The gain value of each step is roughly equivalent to the following gains.

Gain Direct

Gain

Configuration Value

 

0

0dB

1

3dB

2

6dB

3

9dB

4

12dB

5

15dB

6

18dB

7

21dB

8

24dB

9

27dB

10

30dB

Note: When the Day/Night mode is set to AUTO, the AGC OFF cannot be set.

− 29 −

Image 30
Contents Technical Manual VVer Contents Parts Names and Dimensions DimensionsVCC-MD800/700/600/500 Series Parts Names and Dimensions VCC-MD400/MD300 SeriesInterface Board Specifications ConnectionConnection of the Interface Board and Camera Unit Input-Output Terminal Descriptions Input-Output Terminal Layout and SpecificationsExternal Synchronous Signals FFC ComplianceCommunications Protocol Communications FormatDuring Query Command Other than ACK During Query Command ACKDuring Settings Command Communications FlowCommand List for MD800-500 ATWMWB ELS OFF BLC OFFBLC on ELS onOFF AGCAGC ON/OFF SMART1OSD Alarm Alarm OUT OFFAlarm OUT on Line OUT OFF EepromCommand List Query for MD800-500 CS FF− 13 − − 14 − Command List for MD400 − 16 − − 17 − DAY Color Burst on LevelCommand List Query for MD400 ADJ Direct BExample Motion Mask Area Settings Figure Model VCC-MD800/700/600/500/400/300⁃⁃ Status Command 2 Except for MD300 ⁃⁃ Status Command 3 Only MD400⁃⁃ Status Command 4 Only MD800/700/600/500 ⁃⁃ Status Command 5 Only MD800/700/600/500⁃ ⁃ Status Command 6 Only MD800/700/600/500 ⁃⁃ When setting the motion setting to on When unable to set Auto switch setting⁃⁃ When setting Sense UP ⁃⁃ When setting V-RESO UP to on When unable to setModel Code Communications Protocol Zoom Position Control Function DescriptionsZoom Control ⁃⁃ Direct ⁃⁃ Tele/WideFocus Control White Balance ControlIris Control Shutter Speed ControlAGC Control Backlight Compensation 10 Day/Night Switch Control ApertureMotion Detection Details of the Mask Angle and Position Privacy Mask Settings Display Area Ntsc PALSetting the Mask Angle Area Mask Degree Set Area Mask Degree SetSetting the Mask Position Area Mask Position Set To clarify the image when using the stabilizer StabilizerFrequency that can be stabilized Moving Distance Query Command Auto Pursuit FunctionApplication Software Camera Control Command TransmissionCommunications Error RS-232C PortSpectral Sensitivity Characteristics Specifications Ntsc systemPAL system Change history Change history