Function Descriptions
[4] IRIS Control
⁃⁃ Auto Iris
The lens aperture is automatically controlled to correct the brightness of the average luminance value of the image.
⁃⁃ Manual Iris
This fixes the lens aperture. The aperture position can be set to a range of 17 levels (1: close - 7: open) using the Manual IRIS Stop command.
・EI ON
The light intensity can be controlled to a fixed level using an electronic shutter control.
Note: Executing the EI ON command sets the shutter speed mode to OFF.
・EI OFF
This fixes the electronic shutter. Refer to the Shutter Speed Control on the next page regarding fixed values.
⁃⁃ Iris Level
The target brightness can be configured to a range of 0 to 100.
[5] Shutter Speed Control
⁃⁃ Prolonged Exposure Mode
The exposure time is a longer mode than 1 field. The field accumulation time can be configured from 1x to 32x.
However, this cannot be configured during the following conditions.
・When SENSE UP is enabled.
・When MOTION settings are enabled. ・When EI is ON.
⁃⁃ Normal Mode
This is fixed to 1/60 (1/50).
⁃⁃
This can be configured from 1/60 to 1/10000.
Note 1) If flickering is noticeable in regions with a power supply frequency of 50Hz when using NTSC, switch to the
Note 2) When switching to the Prolonged Exposure or
⁃⁃ SENSUP
If the illumination of the subject decreases, the Prolonged Exposure Control is automatically executed along with the AGC Control.
The maximum Field Accumulation Time can be configured to a range of 1x to 32x.
This cannot be configured during the following conditions.
・When the MOTION settings are valid. ・When AGC is OFF.
In addition, the shutter speed mode is set to OFF.
[6] AGC Control
⁃⁃ AGC ON
The gain is automatically controlled and light is fixed to a certain intensity.
The MAX gain of each mode of LOW/NORMAL/ MIDDLE/HIGH is roughly equivalent to the following gains.
AGC Gain (dB)
| LOW | NORMAL | MIDDLE | HIGH |
AUTO | — | 9dB | 12dB | 15dB |
COLOR | 1.5dB | 6dB | 10.5dB | 15dB |
B/W | 6dB | 9dB | 12dB | 15dB |
⁃⁃ AGC OFF
This is the fixed gain mode. The gain value can be manually configured to 11 steps.*
The gain value of each step is roughly equivalent to the following gains.
Gain Direct | Gain | |
Configuration Value | ||
| ||
0 | 0dB | |
1 | 3dB | |
2 | 6dB | |
3 | 9dB | |
4 | 12dB | |
5 | 15dB | |
6 | 18dB | |
7 | 21dB | |
8 | 24dB | |
9 | 27dB | |
10 | 30dB |
Note: When the Day/Night mode is set to AUTO, the AGC OFF cannot be set.
− 29 −