Sanyo VCC-WB4000P Changing a password, MAC Address display, When a password has been changed

Page 22

Network Camera (Wired LAN) Settings

7MAC ADDRESS display

This shows the Mac address for the camera.

Note:

Up to a maximum of 16 individual users can access a single camera on the network at the same time. However, only one user out of this maximum of 16 users can be accessing at Operator or Administrator level at any one time.

Depending on the network environment, it may not be possible for 16 users to be connected to a camera at the same time. Once a user has accessed a camera, the network may not allow further accesses, so if this happens, change the resolution for the transferred data (by reducing it) or change the compression ratio (by increasing it) to reduce the volume of data being transferred.

If a 17th user tries to access a camera, the message “THE UNIT IS BUSY!” will be displayed on their screen. Depending on the network environment, the message “THE UNIT IS BUSY!” may be displayed on a user’s computer screen even when less than 16 users are accessing a camera.

Changing a password

Example: To change the password for the Administrator level (ID3) to “1234”

Passwords can consist of between 4 and 8 numerals.

Delete the current password

(“3333”) in the password column for ID3, type “1234” as the new password for ID3, and then click the [SET] button.

The following window will be displayed.

Check that the details are correct, and then close the window.

If a user at Administrator level accesses a camera while a user at Operator level is accessing the camera, the Administrator level user will have priority. In such cases, the Operator level user will be disconnected and the message “THE UNIT IS DISCONNECTED!” will be displayed on their screen.

If an Operator or Administrator attempts to access the camera while another user with the same access level is accessing the camera, the second access will have priority. In such cases, the first access will be disconnected, and the message “THE AUTHORIZED USER LOGGED IN!” will be displayed on that user’s computer screen.

Depending on the network environment, the speed of data transmission to users may drop if the number of users accessing the same camera increases, and operations such as refreshing of images may become delayed.

(When a password has been changed)

When the camera and the computer are connected once more, the network password entry screen will be displayed, so check the username and type in the new password (“1234”) in the password column for ID3.

English

– 21 –

Image 22
Contents VCC-WB4000P Network CameraContents Precautions FeaturesAccessories Operating environment Name and Function of Each Part Monitor OUT connectorPower indicator Lens mount capName and Function of Each Part Remove the lens mount cap Attach the CS mount-type lens Attaching the LensFor C mount type Flange Back Adjustment Connections Basic ConnectionsConnecting to a LAN ConnectionsWired LAN Settings p Network Camera Wired LAN SettingsInstallation of Plug-in Software to the Computer p Computer Network SET Settings pTurn on the power for the computer Network Camera Wired LAN SettingsInstallation of Plug-in Software to the Computer Click the OK buttonUninstalling the plug-in software Click the Install buttonPlug-in software Cookie Settings Browser SettingsCamera uses cookies Example Subnet mask setting Type Wired LAN SettingsLanguage selection window Initial Camera Screen Image quality mode select buttonsAvailable settings Auto default setting FineAlarm indicator Wireless LAN buttonAlarm button Menu select buttons Red indicator Lit orange alarm recording image playback is not possible Lit green alarm recording image playback is possible Grey indicatorSET button Resolution and Expansion settings default settings 640x480Selection screen example JImage display areaClick the Network menu select button Network SET SettingsSet the password Network SpeedWhen a password has been changed Changing a passwordMAC Address display Changing the Access Level ID2 or ID3 Turn the camera off and then back on againFor Operator access level Access Level SettingsFor User access level Timezone Clock SET SettingsDaylight Saving Mode Daylight SavingCamera Title Camera SettingsLive Image IrisCamera Settings Setting manual white balance ManualSetting the camera title DAY/NIGHT SettingsMode BurstSet Burst to OFF example Click the SET button Auto Mode SettingsColor Mode Settings Set Polarity to no exampleMode Settings Set AGC Gain to +12 dB example Click the SET buttonConnection example Figure Change the DAY/NIGHT setting to Color modeChange the DAY/NIGHT setting to Timer mode IR lampAlarm Settings Click the Alarm menu select buttonAlarm Settings Alarm Buffering SET Setting Set Alarm Buffering to ON, and then click the Detail button External Alarm Sensor SettingAlarm Resolution Set Alarm REC USE to USE and then click the SET buttonMotion Detector SET Settings Set the sensor marksExternal Alarm Sensor and Motion Detector Settings Alarm Output for a Specified Period Motion Detector Level Sensitivity SettingRemote Alarm Operations Set Motion Detector Level to 2 exampleContinuous Alarm Output Set Buffering Area to PRE/POST 0/10 Pre-alarm/Post-alarm RecordingAlarm detected Set Buffering Area to PRE/POST 2/8Example 1 If Priority is set to Picture Quality Recording New Alarm DataFixed Settings During Pre/Post-Alarm Recording Example 2 If Priority is set to TimeSaving to an Expansion Memory Card Alarm Data indicator green will illuminateInsert the expansion memory card Viewing Live Images Viewing the View Frame Screen Viewing Live ImagesClick the View Frame menu select button Descriptions of Alarm Operation Buttons Playing Back Alarm DataPlaying Back Alarm Data in the Camera’s Internal Memory Frame RateClick the Alarm Data indicator while it is red or green Playing Back Alarm DataPlaying Back Alarm Images Stored in a Computer Playing Back Expansion Memory Card ImagesEND ResolutionPrevious Alarm Data Deleting Saving Alarm Images onto a Computer as Still Images Saving Live Images and Alarm ImagesSaving Live Images onto a Computer When the File Download pop-up menu is displayed, click Save Saving Live Images and Alarm ImagesSaving All of a Single Alarm Event onto a Computer Click the Play button and then click the Download buttonWireless LAN device settings TCP/IP settings Wireless LAN SET SettingsCamera wired LAN settings TCP/IP settings Camera wireless LAN settings TCP/IP settingsWireless LAN SET Settings Camera Wireless LAN SettingsDescription of Wireless LAN SET Screen Encipherment SettingsConnecting the camera and installing the software PPP Dial-up SettingsPPP Connection to an Internet Service Provider Double-click the Camset icon on the desktopClick the Save Info File button PPP Dial-up SettingsClick the SET to Camera button Close the Camset windowAuthentication Dial to Provider SettingsProvider TEL. no Camera Computer Dial from PC SettingPPP Connection from a Computer Telephone lineMake the settings in the PPP setting screen Set the following itemsClick the RS-232C menu select button RS-232C Settings RS-232C SETLanguage Selection Click the Language button to change the languageFirmware Version Status CheckingClick the Status menu select button SUB-MICROCOMPUTER VersionGlossary of Terms Glossary of Terms Pre-alarm and post-alarm recording If the camera cannot be connected TroubleshootingIf you forget the IP Address Specifications Dimensions Specifications136 mm 126 mm 12 mm 85 mm 59 mm 51 mm Printed on recycled paper 1AC6P1P2682 L5AM2/XE 0603KP-CZ