Sanyo VCC-WB4000P instruction manual Dial to Provider Settings, Provider TEL. no, Authentication

Page 57
The PPP SET screen will be displayed.

PPP (Dial-up) Settings

DIAL TO PROVIDER Settings

1 Click the [PPP] menu select button.

2 Select “USE” from the “DIAL TO PROVIDER” drop-down list box and then click the [DETAIL] button.

The PPP SET (TO PROVIDER) screen will be displayed.

3 Set the following items for connecting to the access point.

PROVIDER TEL. NO.:

If you need to dial “0” first, type in the number as 0-XXX”.

LOGIN ID: Type in your user ID for the provider.

PASSWORD: Type in your password for the provider.

3

4

4 Select the authentication settings

(AUTHENTICATION).

This sets the authentication protocol to be used when connecting to the access point. Set this to the protocol specified by the Internet Service Provider. It should normally be set to “AUTO”.

Available settings:

AUTO (default setting): PAP or CHAP is chosen automatically as required

PAP: Only PAP authentication is used.

CHAP: Only CHAP authentication is used.

5 IP address and error display

1AUTO IP ADDRESS: The IP address is only displayed while the camera is connected.

2ERROR INFO.: Shows the most recent error information during a PPP connection.

Display details:

Modem timeout or Not connected

Line connection error

Line disconnected

PPP connection error

PPP authentication error

PPP connected and disconnected normally

6 Click the [SET] button.

The PPP SET screen will be displayed.

7 Select the type of telephone line (CIRCUIT TYPE).

This sets the type of telephone circuit that the modem is connecting to.

Available settings:

TONE: For tone dialing circuits

PULSE: For pulse dialing circuits

Note: Set to “TONE” if using a terminal adapter.

8 Type in any AT commands that are required to control the modem.

Type in “AT” at the beginning, and then type in the commands specified by the modem manufacturer followed by a command to change flow control to software control.

– 56 –

English

Image 57
Contents Network Camera VCC-WB4000PContents Precautions FeaturesAccessories Operating environment Power indicator Monitor OUT connectorName and Function of Each Part Lens mount capName and Function of Each Part Attaching the Lens Remove the lens mount cap Attach the CS mount-type lensFor C mount type Flange Back Adjustment Basic Connections ConnectionsConnections Connecting to a LANInstallation of Plug-in Software to the Computer p Network Camera Wired LAN SettingsWired LAN Settings p Computer Network SET Settings pInstallation of Plug-in Software to the Computer Network Camera Wired LAN SettingsTurn on the power for the computer Click the OK buttonClick the Install button Uninstalling the plug-in softwarePlug-in software Browser Settings Cookie SettingsCamera uses cookies Wired LAN Settings Example Subnet mask setting TypeLanguage selection window Available settings Auto default setting Image quality mode select buttonsInitial Camera Screen FineAlarm button Wireless LAN buttonAlarm indicator Menu select buttonsLit green alarm recording image playback is possible Lit orange alarm recording image playback is not possibleRed indicator Grey indicatorSelection screen example Resolution and Expansion settings default settings 640x480SET button JImage display areaSet the password Network SET SettingsClick the Network menu select button Network SpeedChanging a password When a password has been changedMAC Address display Turn the camera off and then back on again Changing the Access Level ID2 or ID3Access Level Settings For Operator access levelFor User access level Daylight Saving Mode Clock SET SettingsTimezone Daylight SavingLive Image Camera SettingsCamera Title IrisSetting manual white balance Manual Camera SettingsDAY/NIGHT Settings Setting the camera titleBurst ModeColor Mode Settings Auto Mode SettingsSet Burst to OFF example Click the SET button Set Polarity to no exampleSet AGC Gain to +12 dB example Click the SET button Mode SettingsChange the DAY/NIGHT setting to Timer mode Change the DAY/NIGHT setting to Color modeConnection example Figure IR lampClick the Alarm menu select button Alarm SettingsAlarm Settings Alarm Buffering SET Setting Alarm Resolution External Alarm Sensor SettingSet Alarm Buffering to ON, and then click the Detail button Set Alarm REC USE to USE and then click the SET buttonSet the sensor marks Motion Detector SET SettingsExternal Alarm Sensor and Motion Detector Settings Remote Alarm Operations Motion Detector Level Sensitivity SettingAlarm Output for a Specified Period Set Motion Detector Level to 2 exampleContinuous Alarm Output Alarm detected Pre-alarm/Post-alarm RecordingSet Buffering Area to PRE/POST 0/10 Set Buffering Area to PRE/POST 2/8Fixed Settings During Pre/Post-Alarm Recording Recording New Alarm DataExample 1 If Priority is set to Picture Quality Example 2 If Priority is set to TimeAlarm Data indicator green will illuminate Saving to an Expansion Memory CardInsert the expansion memory card Viewing Live Images Viewing Live Images Viewing the View Frame ScreenClick the View Frame menu select button Playing Back Alarm Data in the Camera’s Internal Memory Playing Back Alarm DataDescriptions of Alarm Operation Buttons Frame RatePlaying Back Alarm Images Stored in a Computer Playing Back Alarm DataClick the Alarm Data indicator while it is red or green Playing Back Expansion Memory Card ImagesResolution ENDPrevious Alarm Data Deleting Saving Live Images and Alarm Images Saving Alarm Images onto a Computer as Still ImagesSaving Live Images onto a Computer Saving All of a Single Alarm Event onto a Computer Saving Live Images and Alarm ImagesWhen the File Download pop-up menu is displayed, click Save Click the Play button and then click the Download buttonCamera wired LAN settings TCP/IP settings Wireless LAN SET SettingsWireless LAN device settings TCP/IP settings Camera wireless LAN settings TCP/IP settingsCamera Wireless LAN Settings Wireless LAN SET Settings Encipherment Settings Description of Wireless LAN SET ScreenPPP Connection to an Internet Service Provider PPP Dial-up SettingsConnecting the camera and installing the software Double-click the Camset icon on the desktopClick the SET to Camera button PPP Dial-up SettingsClick the Save Info File button Close the Camset windowDial to Provider Settings AuthenticationProvider TEL. no PPP Connection from a Computer Dial from PC SettingCamera Computer Telephone lineSet the following items Make the settings in the PPP setting screenLanguage Selection RS-232C Settings RS-232C SETClick the RS-232C menu select button Click the Language button to change the languageClick the Status menu select button Status CheckingFirmware Version SUB-MICROCOMPUTER VersionGlossary of Terms Glossary of Terms Pre-alarm and post-alarm recording Troubleshooting If the camera cannot be connectedIf you forget the IP Address Specifications Specifications Dimensions136 mm 126 mm 12 mm 85 mm 59 mm 51 mm Printed on recycled paper 1AC6P1P2682 L5AM2/XE 0603KP-CZ