PPP (Dial-up) Settings
9 Make the following settings if required.
• BAUD RATE: Normally “115200 bps”
• DATA SIZE: Normally “8 bits”
• PARITY: Normally “NONE”
• STOP BIT: Normally “1”
10 Once you have finished changing the settings, click the [SET] button.
☞MODEM CONNECTIONS
•The modem should be an
•Large volumes of data may be transmitted depending on the alarm settings, so a
Note: The maximum receiving speed for the V.90 protocol is 56 Kbps, but the transmission speed is 33.6 Kbps. Because of this, the maximum transmission speed for alarm data from a camera or the video server will be
33.6Kbps, even for modems that use the
V.90 protocol.
•The cameras and video server can only use software (Xon/Xoff) flow control. In may cases, the modems may be set up to use hardware (RTS/CTS) flow control. In such cases, you will need to use AT command settings to change the modem settings to
•software flow control.
PPP Connection from a Computer
You can use the
Camera
Computer
Modem
Telephone line
Modem
☞DIAL FROM PC Setting
1 Click the [PPP] menu select button.
The PPP SET screen will be displayed.
2 Select “USE” from the “DIAL FROM PC”
The PPP SET (FROM PC) screen will be displayed.