Seagate ST3146807FC, ST336607FC Implementation, State of the drive prior to testing, Invoking DST

Page 27

Cheetah 10K.6 FC Product Manual, Rev. B

17

The following conditions are considered DST failure conditions:

Seek error after retries are exhausted

Track-follow error after retries are exhausted

Read error after retries are exhausted

Write error after retries are exhausted

Recovered errors will not be reported as diagnostic failures.

5.2.8.2Implementation

This section provides all of the information necessary to implement the DST function on this drive.

5.2.8.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

A Drive Not Ready condition is reported by the drive under the following conditions:

Motor will not spin

Motor will not lock to speed

Servo will not lock on track

Drive cannot read configuration tables from the disc

In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.

5.2.8.2.2Invoking DST

To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7. Refer to the Fibre Channel Interface Product Manual, part number 77767496, for additional information about invoking DST.

5.2.8.2.3Short and extended tests

DST has two testing options:

1.short

2.extended

These testing options are described in the following two subsections.

Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.

Short test (Function Code: 001b)

The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.

Extended test (Function Code: 010b)

The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.

The anticipated length of the Extended test is reported through the Control Mode page.

Image 27
Contents Page Page Page Page Revision Date Writer/Engineer Sheets Affected Revision status summary sheetPage Contents Interface requirements Defect and error managementInstallation Seagate Technology support servicesCheetah 10K.6 FC Product Manual, Rev. B Vii List of FiguresPage Cheetah 10K.6 FC family disc drive ScopeCheetah 10K.6 FC Product Manual, Rev. B Applicable standards and reference documentation Reference documents Australian C-TickKorean MIC Taiwanese BsmiCheetah 10K.6 FC disc drive General descriptionReliability Standard featuresMedia description PerformanceUnformatted and formatted capacities Factory-installed accessoriesFactory-installed options User-installed accessoriesCheetah 10K.6 FC Product Manual, Rev. B Format command execution time in minutes Performance characteristicsInternal drive characteristics Seek performance characteristics Access timeCache operation General performance characteristicsStart/stop time Prefetch/multi-segmented cache controlCaching write data Prefetch operation Reliability specifications Service philosophy Reliability and service Preventive maintenance Service life7 S.M.A.R.T Controlling S.M.A.R.TPerformance impact Predictive failures MillisecondsReporting control Determining rateShort and extended tests State of the drive prior to testingImplementation Invoking DSTShipping Product warrantyLog page entries AbortGeneral DC power requirement notes Physical/electrical specificationsAC power requirements DC power requirements+5V +12V Power sequencingConducted noise immunity Current profilesTypical ST373307FC drive +12V current profile Typical ST3146807FC drive +5V current profile Typical ST373307FC drive +5V current profile ST373307FC Power dissipation ST3146807FCCheetah 10K.6 FC Product Manual, Rev. B ST336607FC TemperatureShock Relative humidityEffective altitude sea level Shock and vibrationPackage size Packaged/product weight Drop height Recommended mounting Air cleanliness Cheetah 10K.6 FC Product Manual, Rev. B VibrationAcoustics Mounting configuration dimensions Mechanical specificationsDefect and error management Drive internal defects/errorsDrive error recovery procedures Maximum recovery time per Read retry Maximum recovery time per Write retryFC-AL system errors Read and write retry count maximum recovery timesInstallation Drive ID/option selectionLED connections Cooling 1 J6 connector requirementsDrive Front Drive orientationAir flow Drive mountingGrounding Fibre Channel task management functions FC-AL featuresFibre Channel link service frames Interface requirementsNPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel Process LoginFibre Channel Process Login Accept NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel fabric loginAccept or NPort Login when sending frames to an initiator Fabric Login Accept ACC payload BytesOption Supported Fibre Channel Arbitrated Loop optionsDual port support FC-AL options supportedSupported commands Command code Command name Command code Supported Command name Supported commandsRead descriptor mode Cheetah 10K.6 FC Product Manual, Rev. B Bytes Data hex Mode Sense dataCheetah 10K.6 FC Product Manual, Rev. B Inquiry data Cheetah 10K.6 FC inquiry dataCheetah 10K.6 FC Product Manual, Rev. B DEF DEF CHG Cheetah 10K.6 FC Product Manual, Rev. B Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical description Physical characteristicsPart description Positions Part number Features Connector requirementsPin Signal name Signal type Pin descriptionsFC-SCA pin descriptions Active LED Out PowerFault LED Out FC-AL transmitters and receiversEnable port bypass signals Motor start controls11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESI Setting Setting Hex DecArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics LED driver signalsDifferential Pecl input Transmit eye diagramLink rate GHz Eye diagram data valuesTechnical Support Seagate Technology support services Online ServicesAutomated Services Presales SupportCustomer Service CSO USA/Canada/Latin America Support ServicesEuropean Support Services Africa/Middle East Support Services Asia/Pacific Support ServicesCall Center Toll-free Direct dial Cheetah 10K.6 FC Product Manual, Rev. B Index FC-AL Cheetah 10K.6 FC Product Manual, Rev. B Plogi Cheetah 10K.6 FC Product Manual, Rev. B Cheetah 10K.6 FC Product Manual, Rev. B
Related manuals
Manual 2 pages 5.2 Kb