Page 48
38 | Cheetah 10K.6 FC Product Manual, Rev. B |
9.1.4Fibre Channel port login
Table 6 identifies the required content of the N_Port Login (PLOGI) payload from an initiator.
Table 6: | N_Port login (PLOGI) payload | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
Bytes | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
0-15 | 03 | 00 | 00 | 00 | XX | XX | BB | BB | CF | XX | FS | FS | XX | XX | XX | XX | Common |
| | | | | | | | | | | | | | | | | |
16-31 | XX | XX | XX | XX | PN | PN | PN | PN | PN | PN | PN | PN | NN | NN | NN | NN | |
| | | | | | | | | | | | | | | | | |
32-35 | NN | NN | NN | NN | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
36-47 | | | | | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | Class 1 |
| | | | | | | | | | | | | | | | | |
48-51 | XX | XX | XX | XX | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
52-63 | | | | | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | Class 2 |
| | | | | | | | | | | | | | | | | |
64-67 | XX | XX | XX | XX | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
68-79 | | | | | SO | SO | IC | IC | XX | XX | FS | FS | XX | CS | XX | XX | Class 3 |
| | | | | | | | | | | | | | | | | |
80-83 | OS | OS | XX | XX | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
84-95 | | | | | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | Reserved |
| | | | | | | | | | | | | | | | | |
96-99 | XX | XX | XX | XX | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
100-111 | | | | | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | XX | Vendor |
| | | | | | | | | | | | | | | | | |
112-115 | XX | XX | XX | XX | | | | | | | | | | | | | Version |
| | | | | | | | | | | | | | | | | |
XIndicates a four-bit (hex) field is not checked.
x Indicates a single bit is not checked.
BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0).
CF | Common features. This binary field selects the common features requested by the initiator login. |
| MSB | Continuously increasing offset | Must = 1 |
| | Random relative offset | Not checked. Port Login Accept will return a 0—not supported. |
| | Valid version level | x |
| | N_Port/F_Port | Must = 0, N_Port |
| | Alternate credit model | Must = 1 |
| | Other bits reserved | xxx XX |
FS | Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a |
| multiple of four bytes. For multiple frame sequences, all frames but the last frame of the sequence must be this size. Only the |
| receive buffer field size in the Class 3 parameters is used. |
PN | Port name (initiator’s)—saved with the login parameters. If a change of the port name/AL_PA address association is detected dur- |
| ing a Port DISCovery, and implicit logout occurs and the initiator returns a LS_RJT. |
NN | Node name. The node name is not checked or saved by the drive. |
SO | Service options Class 3 only. | |
| MSB | Class valid | Must = 1 |
| | Intermix | x |
| | Stacked connection req. | xx |
| | Sequential delivery | x |
| | Other bits reserved | xxx XX |
IC | Initiator control | |
| MSB | XID reassign | xx |
| | Proc Assc | 10 or 11 causes the login to be rejected. Other values are accepted. |
| | Other bits | XXX |
CS | Concurrent sequences | Must be a value greater than 0. |
OS | Open sequences per exchange | Must be a value greater than 0. |
Contents
Page
Page
Page
Page
Revision status summary sheet
Revision Date Writer/Engineer Sheets Affected
Page
Contents
Defect and error management
Installation
Seagate Technology support services
Interface requirements
List of Figures
Cheetah 10K.6 FC Product Manual, Rev. B Vii
Page
Scope
Cheetah 10K.6 FC family disc drive
Cheetah 10K.6 FC Product Manual, Rev. B
Applicable standards and reference documentation
Australian C-Tick
Korean MIC
Taiwanese Bsmi
Reference documents
General description
Cheetah 10K.6 FC disc drive
Standard features
Media description
Performance
Reliability
Factory-installed accessories
Factory-installed options
User-installed accessories
Unformatted and formatted capacities
Cheetah 10K.6 FC Product Manual, Rev. B
Performance characteristics
Internal drive characteristics
Seek performance characteristics Access time
Format command execution time in minutes
General performance characteristics
Start/stop time
Prefetch/multi-segmented cache control
Cache operation
Caching write data
Prefetch operation
Reliability specifications
Reliability and service
Preventive maintenance
Service life
Service philosophy
7 S.M.A.R.T
Controlling S.M.A.R.T
Performance impact
Milliseconds
Reporting control
Determining rate
Predictive failures
State of the drive prior to testing
Implementation
Invoking DST
Short and extended tests
Product warranty
Log page entries
Abort
Shipping
Physical/electrical specifications
AC power requirements
DC power requirements
General DC power requirement notes
Power sequencing
Conducted noise immunity
Current profiles
+5V +12V
Typical ST373307FC drive +12V current profile
Typical ST3146807FC drive +5V current profile
Typical ST373307FC drive +5V current profile
Power dissipation ST3146807FC
ST373307FC
Temperature
Cheetah 10K.6 FC Product Manual, Rev. B ST336607FC
Relative humidity
Effective altitude sea level
Shock and vibration
Shock
Package size Packaged/product weight Drop height
Recommended mounting
Air cleanliness
Cheetah 10K.6 FC Product Manual, Rev. B Vibration
Acoustics
Mechanical specifications
Mounting configuration dimensions
Defect and error management
Drive internal defects/errors
Drive error recovery procedures
Read retry Maximum recovery time per Write retry
FC-AL system errors
Read and write retry count maximum recovery times
Maximum recovery time per
Installation
Drive ID/option selection
LED connections
1 J6 connector requirements
Drive Front
Drive orientation
Cooling
Drive mounting
Air flow
Grounding
FC-AL features
Fibre Channel link service frames
Interface requirements
Fibre Channel task management functions
Fibre Channel port login
NPort login Plogi payload Bytes
Fibre Channel Process Login
Fibre Channel Process Login Accept
NPort Login Accept ACC payload Bytes
Process Login Plri payload
Fibre Channel fabric login
Fabric Login Flogi payload Bytes
Fabric Login Accept ACC payload Bytes
Accept or NPort Login when sending frames to an initiator
Fibre Channel Arbitrated Loop options
Dual port support
FC-AL options supported
Option Supported
Supported commands Command code Command name
Supported commands
Command code Supported Command name
Read descriptor mode
Cheetah 10K.6 FC Product Manual, Rev. B
Mode Sense data
Cheetah 10K.6 FC Product Manual, Rev. B Inquiry data
Cheetah 10K.6 FC inquiry data
Bytes Data hex
Cheetah 10K.6 FC Product Manual, Rev. B
DEF
DEF CHG
Cheetah 10K.6 FC Product Manual, Rev. B
Miscellaneous operating features and conditions
Miscellaneous features
Supported Feature or condition
Miscellaneous status
Physical characteristics
Physical description
Connector requirements
Part description Positions Part number Features
Pin Signal name Signal type
Pin descriptions
FC-SCA pin descriptions
Power
Fault LED Out
FC-AL transmitters and receivers
Active LED Out
Enable port bypass signals
Motor start controls
11 SEL6 through SEL0 ID lines
Parallel Enclosure Services Interface ESI
Setting
Setting Hex Dec
Arbitrated loop physical address Alpa values
Signal characteristics
TTL input characteristics
LED driver signals
Device control codes
Transmit eye diagram
Differential Pecl input
Eye diagram data values
Link rate GHz
Seagate Technology support services Online Services
Automated Services
Presales Support
Technical Support
Customer Service CSO
USA/Canada/Latin America Support Services
European Support Services
Africa/Middle East Support Services
Asia/Pacific Support Services
Call Center Toll-free Direct dial
Cheetah 10K.6 FC Product Manual, Rev. B
Index
FC-AL
Cheetah 10K.6 FC Product Manual, Rev. B
Plogi
Cheetah 10K.6 FC Product Manual, Rev. B
Cheetah 10K.6 FC Product Manual, Rev. B