Seagate ST336607FC, ST3146807FC, ST373307FC manual Cheetah 10K.6 FC Product Manual, Rev. B

Page 58

48

Cheetah 10K.6 FC Product Manual, Rev. B

3.Current values

Current values are volatile values being used by the drive to control its operation. A Mode Select command can be used to change the values identified as changeable values. Originally, current values are installed from saved or default values after a power on reset, hard reset, Target Reset, or LIP Reset.

4.Changeable values

Changeable values form a bit mask, stored in nonvolatile memory, that dictates which of the current values and saved values can be changed by a Mode Select command. A one (1) indicates the value can be changed. A zero (0) indicates the value is not changeable. For example, in Table 15, refer to Mode page 81, in the row entitled “CHG.” These are hex numbers representing the changeable values for Mode page 81. Note in columns 5 and 6 (bytes 04 and 05), there is 00h which indicates that in bytes 04 and 05 none of the bits are changeable. Note also that bytes 06, 07, 09, 10, and 11 are not changeable, because those fields are all zeros. In byte 02, hex value FF equates to the binary pattern 11111111. If there is a zero in any bit position in the field, it means that bit is not changeable. Since all of the bits in byte 02 are ones, all of these bits are changeable.

The changeable values list can only be changed by downloading new firmware into the flash E-PROM.

Note. Because there are often several different versions of drive control firmware in the total population of drives in the field, the Mode Sense values given in the following tables may not exactly match those of some drives.

The following tables list the values of the data bytes returned by the drive in response to the Mode Sense com- mand pages for SCSI implementation (see the Fibre Channel Interface Manual ).

Definitions:

DEF = Default value. Standard OEM drives are shipped configured this way.

CHG = Changeable bits; indicates if default value is changeable.

Image 58
Contents Page Page Page Page Revision status summary sheet Revision Date Writer/Engineer Sheets AffectedPage Contents Seagate Technology support services Defect and error managementInstallation Interface requirementsList of Figures Cheetah 10K.6 FC Product Manual, Rev. B ViiPage Scope Cheetah 10K.6 FC family disc driveCheetah 10K.6 FC Product Manual, Rev. B Applicable standards and reference documentation Taiwanese Bsmi Australian C-TickKorean MIC Reference documentsGeneral description Cheetah 10K.6 FC disc drivePerformance Standard featuresMedia description ReliabilityUser-installed accessories Factory-installed accessoriesFactory-installed options Unformatted and formatted capacitiesCheetah 10K.6 FC Product Manual, Rev. B Seek performance characteristics Access time Performance characteristicsInternal drive characteristics Format command execution time in minutesPrefetch/multi-segmented cache control General performance characteristicsStart/stop time Cache operationCaching write data Prefetch operation Reliability specifications Service life Reliability and servicePreventive maintenance Service philosophyControlling S.M.A.R.T 7 S.M.A.R.TPerformance impact Determining rate MillisecondsReporting control Predictive failuresInvoking DST State of the drive prior to testingImplementation Short and extended testsAbort Product warrantyLog page entries ShippingDC power requirements Physical/electrical specificationsAC power requirements General DC power requirement notesCurrent profiles Power sequencingConducted noise immunity +5V +12VTypical ST373307FC drive +12V current profile Typical ST3146807FC drive +5V current profile Typical ST373307FC drive +5V current profile Power dissipation ST3146807FC ST373307FCTemperature Cheetah 10K.6 FC Product Manual, Rev. B ST336607FCShock and vibration Relative humidityEffective altitude sea level ShockPackage size Packaged/product weight Drop height Recommended mounting Cheetah 10K.6 FC Product Manual, Rev. B Vibration Air cleanlinessAcoustics Mechanical specifications Mounting configuration dimensionsDrive internal defects/errors Defect and error managementDrive error recovery procedures Read and write retry count maximum recovery times Read retry Maximum recovery time per Write retryFC-AL system errors Maximum recovery time perDrive ID/option selection InstallationLED connections Drive orientation 1 J6 connector requirementsDrive Front CoolingDrive mounting Air flowGrounding Interface requirements FC-AL featuresFibre Channel link service frames Fibre Channel task management functionsFibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel Process LoginFibre Channel Process Login Accept Process Login Plri payloadFibre Channel fabric login Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Accept or NPort Login when sending frames to an initiatorFC-AL options supported Fibre Channel Arbitrated Loop optionsDual port support Option SupportedSupported commands Command code Command name Supported commands Command code Supported Command name Read descriptor mode Cheetah 10K.6 FC Product Manual, Rev. B Cheetah 10K.6 FC inquiry data Mode Sense dataCheetah 10K.6 FC Product Manual, Rev. B Inquiry data Bytes Data hexCheetah 10K.6 FC Product Manual, Rev. B DEF DEF CHG Cheetah 10K.6 FC Product Manual, Rev. B Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical characteristics Physical descriptionConnector requirements Part description Positions Part number FeaturesPin descriptions Pin Signal name Signal typeFC-SCA pin descriptions FC-AL transmitters and receivers PowerFault LED Out Active LED OutMotor start controls Enable port bypass signals11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESI Setting Hex Dec SettingArbitrated loop physical address Alpa values LED driver signals Signal characteristicsTTL input characteristics Device control codesTransmit eye diagram Differential Pecl inputEye diagram data values Link rate GHzPresales Support Seagate Technology support services Online ServicesAutomated Services Technical SupportUSA/Canada/Latin America Support Services Customer Service CSOEuropean Support Services Asia/Pacific Support Services Africa/Middle East Support ServicesCall Center Toll-free Direct dial Cheetah 10K.6 FC Product Manual, Rev. B Index FC-AL Cheetah 10K.6 FC Product Manual, Rev. B Plogi Cheetah 10K.6 FC Product Manual, Rev. B Cheetah 10K.6 FC Product Manual, Rev. B
Related manuals
Manual 2 pages 5.2 Kb