Sekonic L-758DR manual Digitalmaster

Page 1

DIGITALMASTER

L-758DR

L-758D L-758

Operating Manual

Image 1
Contents Digitalmaster Blank Safety Precautions Table of Contents Optional Accessories Technical Data Care and Maintenance FCC & IC compliance information Light Meter Parts Parts Designation758DR 758D/L-758CINESupplied Accessories Page Page Explanation of the Liquid Crystal Display Explanation of the Liquid Crystal Display Inserting the battery Before UsingChecking battery capacity Attach the strapSetting ISO 1 sensitivity Auto Power Off functionSetting ISO 2 sensitivity Jog Wheel Lock or Lock Off Incident Incident or reflected spot measuring Basic OperationLUX, FC Setting measuring modeIncident Measurement Mode Reflected Measurement Mode spot metering Measurement Shutter Speed Priority modeMeasuring ambient light Measurement Aperture Priority mode EV mode Cinematography Measurement. Release the Measuring button to Measuring electronic flash Cord Flash modeAuto-reset cordless flash mode Percentage Cord multiple flash cumulative mode Cordless multiple flash cumulative mode Measurement Flash analyzing function Wireless Flash Radio Triggering Abcd RT-32FCC Memory function Advanced FunctionsContrast function Averaging functionMemory button Indicator of reading Set shutter speed 160000 230000 EV value → Foot-lambert FL conversion table How to use the Exposure compensation function How to use Calibration compensation function Filter compensation Filters, LCD Display and Corrected Value Filter factor number compensation 2 L-758CINE onlyCustom setting function Custom setting no Camera Exposure Profiling Calibration testing for exposure profilingCamera Exposure Profiling Sekonic Application Software Input test target dataOutline of software Manual Exposure Profile Input Camera Exposure Profiling Camera Exposure Profiling Aperture scale Analog scaleEV scale 3 MID.TONE button Points will be displayed as fast blinking IconsCamera Exposure Profiling Camera Exposure Profiling Synchro cord Optional Accessories18% Gray Card Lens Hood/Step-Up Ring 30.5mm → 40.5mmRT-32CE Technical Data FCC & IC Care and Maintainance Maintenance NotesFCC ID FCC & IC compliance informationPage Memo Memo Blank TEL +810 3-3978-2335 FAX+8103-3978-5229