5.Measurement

2.When the light from the flash is received, the measured value (f stop) is displayed. Each time this is repeated, the accumulated value for the aperture and the number of cumulative flashes is displayed.

Percentage of flash in total exposure

Measured f stop

Number of

cumulative flashes

1/10 f stop

 

 

Set

Measured f stop

 

 

shutter speed

 

 

(total exposure)

 

 

 

1st. time

2nd. time

 

3rd. time

3.The ready to measure mode will be displayed for approximately 90 seconds. If the 90 second period is exceeded and the blinking mark stops, press the Measuring button again. The measured value (f stop) of the previous time reverts to 0 and the meter is in ready to measure mode.

NOTE:

When firing a flash, if the flash brightness is 8 EV lower than the ambient light, the meter may fail to detect the light. In this case, make measurements using the flash with cord multiple flash (cumulative) mode (see page 24) or wireless multiple flash radio triggering mode (see page 29).

Rapid start fluorescent lamps and special lighting are sometimes mistaken for flash, and accidentally measured. In this case, make measurements using the flash with cord multiple flash (cumulative) mode (see page 24) or wireless multiple flash radio triggering mode (see page 29).

Waveform of flashbulb is gentle slope and there is a possibility that light meter cannot recognize the flashbulb in Cordless flash mode. In this case, be sure to take measurement in cord multiple flash (cumulative) mode (see page 24) or wireless multiple flash radio triggering mode (see page 29).

EV scale cannot display in flash cumulative mode.

Reference:

Setting the shutter speed is similar to the previous instruction (see page 22).

Readings outside the display range or beyond the measuring range are similar to the previous instruction. (See page 16) of “Shutter speed priority mode” of section 1- 1.

If the ISO sensitivity is changed after the measurement is taken, the new converted measured value (f stop value) will be displayed.

-26-

Image 32
Contents Digitalmaster Blank Safety Precautions Table of Contents Optional Accessories Technical Data Care and Maintenance FCC & IC compliance information Parts Designation Light Meter Parts758DR 758D/L-758CINESupplied Accessories Page Page Explanation of the Liquid Crystal Display Explanation of the Liquid Crystal Display Before Using Inserting the batteryChecking battery capacity Attach the strapSetting ISO 2 sensitivity Auto Power Off functionSetting ISO 1 sensitivity Jog Wheel Lock or Lock Off Incident Basic Operation Incident or reflected spot measuringSetting measuring mode LUX, FCIncident Measurement Mode Reflected Measurement Mode spot metering Measuring ambient light Shutter Speed Priority modeMeasurement Measurement Aperture Priority mode EV mode Cinematography Measurement. Release the Measuring button to Cord Flash mode Measuring electronic flashAuto-reset cordless flash mode Percentage Cord multiple flash cumulative mode Cordless multiple flash cumulative mode Measurement Flash analyzing function Wireless Flash Radio Triggering Abcd RT-32FCC Advanced Functions Memory functionAveraging function Contrast functionMemory button Indicator of reading Set shutter speed 160000 230000 EV value → Foot-lambert FL conversion table How to use the Exposure compensation function How to use Calibration compensation function Filter compensation Filter factor number compensation 2 L-758CINE only Filters, LCD Display and Corrected ValueCustom setting function Custom setting no Calibration testing for exposure profiling Camera Exposure ProfilingCamera Exposure Profiling Outline of software Input test target dataSekonic Application Software Manual Exposure Profile Input Camera Exposure Profiling Camera Exposure Profiling EV scale Analog scaleAperture scale Points will be displayed as fast blinking Icons 3 MID.TONE buttonCamera Exposure Profiling Camera Exposure Profiling Optional Accessories Synchro cord18% Gray Card Lens Hood/Step-Up Ring 30.5mm → 40.5mmRT-32CE Technical Data FCC & IC Maintenance Notes Care and MaintainanceFCC & IC compliance information FCC IDPage Memo Memo Blank TEL +810 3-3978-2335 FAX+8103-3978-5229