Sekonic L-758DR manual Explanation of the Liquid Crystal Display

Page 11

2. Explanation of the Liquid Crystal Display

Analog Scale

Displays measured values as icons along the apertures or Latitude EV scale. The scale is graduated in full or 1/3 stop increments for measurements. Memorized and averaged values are also display along the scale.

Aperture scale (upper scale) displays in all mode except Aperture priority mode.

f 0.7 to f 90 in full stops appears in all modes except aperture priority mode (L-758)

f 0.5 to f 64 in full stops appears in all modes except aperture priority mode (L-758CINE)

EV scale (lower scale) displays in all mode except Multiple flash cumulative mode.

+/-7 stops from Mid.Tone (0) appears in aperture priority mode, or other modes if selected.

Value display scale

Appear to indicate last measured/ memorized/ averaged values and brightness differ- ence value below the aperture scale or above the latitude scale depending on which scale has been selected.

Appears when measurement is below display range

Blinks when measurement is below measurement range

Appears when measurement is above display range

Blinks when measurement is above measurement range

Dynamic range/clipping point icons

Indicates dynamic range and clipping point of a selected camera exposure profiling.

Shutter priority indicator, shutter speed display for still photography or frames per second (f/s) for cinematography

Appears when Shutter Priority (T) is selected mode (see page 15)

Appears when shutter speed is in minutes

Appears when shutter speed is in full seconds

Appears when cine speed is set in frames per second (see page 19)

Battery Power Indicator (see page 7)

Memory / Multiple Flash Indicator Display

Appears when Multi (cumulative) flash measurement mode is selected and shows the cumulated number of flash measurements (see page 24)

Appears when reading is memorized and shows the number in memory (see page 31)

Radio triggering channel and Quad-triggering zone display (see page 28)

Triggering Channel Numbers

Selective Quad-Triggering Zone

Camera profile selector display

USB icon

Appears when a USB cable is connected to the light meter and a computer.

-5-

Image 11
Contents Digitalmaster Blank Safety Precautions Table of Contents Optional Accessories Technical Data Care and Maintenance FCC & IC compliance information 758D/L-758CINE Parts DesignationLight Meter Parts 758DRSupplied Accessories Page Page Explanation of the Liquid Crystal Display Explanation of the Liquid Crystal Display Attach the strap Before UsingInserting the battery Checking battery capacitySetting ISO 2 sensitivity Auto Power Off functionSetting ISO 1 sensitivity Jog Wheel Lock or Lock Off Incident Incident or reflected spot measuring Basic OperationLUX, FC Setting measuring modeIncident Measurement Mode Reflected Measurement Mode spot metering Measuring ambient light Shutter Speed Priority modeMeasurement Measurement Aperture Priority mode EV mode Cinematography Measurement. Release the Measuring button to Measuring electronic flash Cord Flash modeAuto-reset cordless flash mode Percentage Cord multiple flash cumulative mode Cordless multiple flash cumulative mode Measurement Flash analyzing function Wireless Flash Radio Triggering Abcd RT-32FCC Memory function Advanced FunctionsContrast function Averaging functionMemory button Indicator of reading Set shutter speed 160000 230000 EV value → Foot-lambert FL conversion table How to use the Exposure compensation function How to use Calibration compensation function Filter compensation Filters, LCD Display and Corrected Value Filter factor number compensation 2 L-758CINE onlyCustom setting function Custom setting no Camera Exposure Profiling Calibration testing for exposure profilingCamera Exposure Profiling Outline of software Input test target dataSekonic Application Software Manual Exposure Profile Input Camera Exposure Profiling Camera Exposure Profiling EV scale Analog scaleAperture scale 3 MID.TONE button Points will be displayed as fast blinking IconsCamera Exposure Profiling Camera Exposure Profiling Lens Hood/Step-Up Ring 30.5mm → 40.5mm Optional AccessoriesSynchro cord 18% Gray CardRT-32CE Technical Data FCC & IC Care and Maintainance Maintenance NotesFCC ID FCC & IC compliance informationPage Memo Memo Blank TEL +810 3-3978-2335 FAX+8103-3978-5229