Sekonic L-758DR manual Points will be displayed as fast blinking Icons, 3 MID.TONE button

Page 55

7. Camera Exposure Profiling

2) The EV scale displays Clipping points(+/-),Dy- namic range(+/-)and Mid. Tone with a triangle " "icon.

3) Measured value exceeding Dynamic range will

 

 

 

 

 

 

Clipping point(-)

 

 

Clipping point(+)

be displayed as a slow blinking " "

Dynamic range(-)

Dynamic range(+)

icons.Measurements that exceed the clipping

 

Mid.Tone

points will be displayed as fast blinking " "

 

 

 

 

 

 

icons.

 

 

 

 

 

 

Exceed dynamic

Exceed clipping

range(blinking slowly)

point (blinking faster)

Mid. Tone (blinking)

Reference:

In the custom setting mode (see page 40), it is possible to select how to indicate the clipping points and the dynamic range. Below are the three display choices.

Five point

Inside Range

Outside Range

3-2-3 MID.TONE button

This button is used to set the measured value in the center of EV scale.

1) Take a measurement by pressing the Measur- ing button . Press MID.TONE button to set the Mid.Tone on the scale. ” ” in the center of the EV scale will blink continuously twice to indicate that the Mid.Tone has been set.

-49-

Image 55
Contents Digitalmaster Blank Safety Precautions Table of Contents Optional Accessories Technical Data Care and Maintenance FCC & IC compliance information 758D/L-758CINE Parts DesignationLight Meter Parts 758DRSupplied Accessories Page Page Explanation of the Liquid Crystal Display Explanation of the Liquid Crystal Display Attach the strap Before UsingInserting the battery Checking battery capacitySetting ISO 1 sensitivity Auto Power Off functionSetting ISO 2 sensitivity Jog Wheel Lock or Lock Off Incident Incident or reflected spot measuring Basic OperationLUX, FC Setting measuring modeIncident Measurement Mode Reflected Measurement Mode spot metering Measurement Shutter Speed Priority modeMeasuring ambient light Measurement Aperture Priority mode EV mode Cinematography Measurement. Release the Measuring button to Measuring electronic flash Cord Flash modeAuto-reset cordless flash mode Percentage Cord multiple flash cumulative mode Cordless multiple flash cumulative mode Measurement Flash analyzing function Wireless Flash Radio Triggering Abcd RT-32FCC Memory function Advanced FunctionsContrast function Averaging functionMemory button Indicator of reading Set shutter speed 160000 230000 EV value → Foot-lambert FL conversion table How to use the Exposure compensation function How to use Calibration compensation function Filter compensation Filters, LCD Display and Corrected Value Filter factor number compensation 2 L-758CINE onlyCustom setting function Custom setting no Camera Exposure Profiling Calibration testing for exposure profilingCamera Exposure Profiling Sekonic Application Software Input test target dataOutline of software Manual Exposure Profile Input Camera Exposure Profiling Camera Exposure Profiling Aperture scale Analog scaleEV scale 3 MID.TONE button Points will be displayed as fast blinking IconsCamera Exposure Profiling Camera Exposure Profiling Lens Hood/Step-Up Ring 30.5mm → 40.5mm Optional AccessoriesSynchro cord 18% Gray CardRT-32CE Technical Data FCC & IC Care and Maintainance Maintenance NotesFCC ID FCC & IC compliance informationPage Memo Memo Blank TEL +810 3-3978-2335 FAX+8103-3978-5229