Sekonic L-758DR manual EV value → Foot-lambert FL conversion table

Page 41

6. Advanced Functions

5.How to use a reflected luminance (cd/m2 or FL) meter (L-758DR/758D)

1.Exposure/Calibration compensation: see page 36 & 37, Compensation of camera exposure

profile: see page 46.

2.Set the meter to EV mode and ISO 100.

3.Set meter to spot reading for reflected light.

Take the measurement by looking through the finder and aligning so the subject that will be measured is inside the circle.

4.The measured EV can be converted to find the brightness level with the conversion table below.

*

EV value

cd/m2 conversion table

 

 

 

 

Decimal places

0

0.5

 

Decimal places

0

0.5

EV

 

EV

 

 

 

 

 

 

1

0.25

0.35

 

11

260

360

 

2

0.5

0.7

 

12

510

720

 

3

1

1.4

 

13

1000

1400

 

4

2

2.8

 

14

2000

2900

 

5

4

6

 

15

4100

5800

 

6

8

11

 

16

8200

12000

 

7

16

23

 

17

16000

23000

 

8

32

45

 

18

33000

46000

 

9

64

91

 

19

66000

93000

 

10

130

180

 

 

 

 

*

EV value

Foot-lambert (FL) conversion table

 

 

 

 

 

 

 

 

 

 

 

Decimal places

0

0.5

 

Decimal places

0

0.5

EV

 

EV

 

 

 

 

 

 

1

0.073

0.10

 

11

75

110

 

2

0.15

0.20

 

12

150

210

 

3

0.30

0.40

 

13

300

420

 

4

0.60

0.80

 

14

600

850

 

5

1.2

1.7

 

15

1200

1700

 

6

2.3

3.3

 

16

2400

3400

 

7

4.7

6.6

 

17

4800

7000

 

8

9.3

13

 

18

9000

14000

 

9

19

26

 

19

19000

27000

 

10

37

53

 

 

 

 

Reference:

L-758CINE can read cd/m2 or FL directly when the custom setting function is used (refer to page 40).

-35-

Image 41
Contents Digitalmaster Blank Safety Precautions Table of Contents Optional Accessories Technical Data Care and Maintenance FCC & IC compliance information Light Meter Parts Parts Designation758DR 758D/L-758CINESupplied Accessories Page Page Explanation of the Liquid Crystal Display Explanation of the Liquid Crystal Display Inserting the battery Before UsingChecking battery capacity Attach the strapSetting ISO 2 sensitivity Auto Power Off functionSetting ISO 1 sensitivity Jog Wheel Lock or Lock Off Incident Incident or reflected spot measuring Basic OperationLUX, FC Setting measuring modeIncident Measurement Mode Reflected Measurement Mode spot metering Measuring ambient light Shutter Speed Priority modeMeasurement Measurement Aperture Priority mode EV mode Cinematography Measurement. Release the Measuring button to Measuring electronic flash Cord Flash modeAuto-reset cordless flash mode Percentage Cord multiple flash cumulative mode Cordless multiple flash cumulative mode Measurement Flash analyzing function Wireless Flash Radio Triggering Abcd RT-32FCC Memory function Advanced FunctionsContrast function Averaging functionMemory button Indicator of reading Set shutter speed 160000 230000 EV value → Foot-lambert FL conversion table How to use the Exposure compensation function How to use Calibration compensation function Filter compensation Filters, LCD Display and Corrected Value Filter factor number compensation 2 L-758CINE onlyCustom setting function Custom setting no Camera Exposure Profiling Calibration testing for exposure profilingCamera Exposure Profiling Outline of software Input test target dataSekonic Application Software Manual Exposure Profile Input Camera Exposure Profiling Camera Exposure Profiling EV scale Analog scaleAperture scale 3 MID.TONE button Points will be displayed as fast blinking IconsCamera Exposure Profiling Camera Exposure Profiling Synchro cord Optional Accessories18% Gray Card Lens Hood/Step-Up Ring 30.5mm → 40.5mmRT-32CE Technical Data FCC & IC Care and Maintainance Maintenance NotesFCC ID FCC & IC compliance informationPage Memo Memo Blank TEL +810 3-3978-2335 FAX+8103-3978-5229