ABC Office DC-2, MC-1 manual Set Record/Zone2 Input, Clear Record/Zone2 Input

Page 27

Lexicon, Inc.

 

DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

7.3.22 Set Record/Zone2 Input

Sets the Record/Zone 2 input. If Record/Zone2 was inactive, this command will set the input then activate the Record/Zone 2 function.

7.3.22.1 Command Packet Description

Application Header:

Command

DC_CMD_SET_REC_INPUT

0x25

Data Count

1

0x01

Application Data:

 

Data[0]

InputId

nn

7.3.22.2 Data Description

InputId:

 

Data Type:

Unsigned 8 bit Integer

Max Value:

7

Conversion:

Input Id’s are defined in Appendix D Input Id’s

7.3.22.3DC-2/MC-1 Response

7.3.22.4Data Validation:

The InputId must be a valid Input Id. If it is not the DC-2/MC-1 will respond with a NAK packet and error code DC_ERR_ INVALID_INPUT_ID. If the input selection is disallowed(input blocked, digital input not selected…) DC-2/MC-1 will respond with a NAK packet and error code DC_ERR_INVALID_INPUT If the input is assigned the DC-2/MC-1 will respond with an ACK Packet.

7.3.23 Clear Record/Zone2 Input

Clears or Unassign’s the Record/Zone 2 input. If Record/Zone2 is active, this command will unassign the zone 2 input and set the record outputs to the main input source.

7.3.23.1 Packet Description

Application Header:

Command

DC_CMD_CLEAR_REC_INPUT

0x26

Data Count

1

0x01

Application Data:

 

Data[0]

InputId

nn

7.3.23.2 Data Description

InputId:

 

Data Type:

Unsigned 8 bit Integer

Max Value:

7

Conversion:

Input Id’s are defined in Appendix D Input Id’s

7.3.23.3DC-2/MC-1 Response

7.3.23.4Data Validation

The InputId must be a valid Input Id. If it is not the DC-2/MC-1 will respond with a NAK packet and error code DC_ERR_ INVALID_INPUT_ID. If the input is unassigned the DC-2/MC-1 will respond with an ACK Packet. If the record/zone 2 function was not active the DC-2/MC-1 will respond with an ACK packet.

27 of 44

Image 27
Contents Serial Communications Protocol Definition Data Link Layer Internal Use General Description DocumentsDefinitions AbbreviationsDB-9 RS232 Connector Physical LayerSerial Port Driver Data Link Layer ErrorsDC-2/MC-1 Receive Buffer DC-2/MC-1 Hardware VerificationNotification Packet Description Application LayerDC-2/MC-1 Asynchronous Notification Packets Wakeup NotificationData Description Sleep NotificationFront Panel Display Buffer Host Response ExpectedSupported System Parameters Host ResponseAcknowledgment Packets AcknowledgeNo Acknowledge Send IR Command Host Initiated Command PacketsReset Unit Restore DefaultsData Validation Get DC-2/MC-1 Unit Configuration4.2 DC-2/MC-1 Unit Configuration Response Packet 3.3 DC-2/MC-1 ResponseSW Level Product IDSW Type THX AC3 DTSGet System Status System Status Response PacketDcrespsysstatus INSTREAMAC351 Get Record/Zone 2 StatusRateunknown RATE44 RATE48 RATE88 RATE96Dccmdgetrecstatus Get System Parameter Definition by Id Command PacketGet System Parameter Definition Record/Zone2 Status Response PacketDcrespsysparamdef Get System Parameter Definition by Name Command PacketSystem Parameter Definition Response Packet DccmdgetsysparambynameEffect Definition Response Packet Get System Parameter ValuesGet Effect Definition by Id System Parameter Values Response PacketDccmdgeteffectparamdef Get Effect Parameter DefinitionEffect Parameter Definition Response Packet DcrespeffectdefApplicationHeader Get Effect Parameter Values10.5 Data Description Effect Parameter Values Response PacketGet Custom Name Get Input Name by IdData Description Custom Name Response Packet Get FPD Control Registers Input Name Response PacketFPD Control Register Response Packet Dcrespfpdcontrol Set System Parameter ValuesSet Effect Parameter Values 15.3 DC-2/MC-1 ResponseDccmdseteffectparamvalues Set Effect Name by Effect Id16.3 DC-2/MC-1 Response 17.3 DC-2/MC-1 Response19.3 DC-2/MC-1 Response Set System VolumeSet Main Balance 18.3 DC-2/MC-1 Response20.3 DC-2/MC-1 Response Set Front/Back BalanceSet Active Effect by Id Packet Description23.3 DC-2/MC-1 Response Data Validation Set Record/Zone2 InputClear Record/Zone2 Input 22.3 DC-2/MC-1 Response Data Validation24.3 DC-2/MC-1 Response Set Zone2 VolumeSet Zone2 Left/Right Balance Set Custom NameDccmdsetcustname Set Input Name by Id26.3 DC-2/MC-1 Response 27.3 DC-2/MC-1 ResponseData Description 29.3 DC-2/MC-1 Response Set FPD Control RegistersHost Wakeup 28.3 DC-2/MC-1 ResponseGet Communication Configuration Host Sleep31.3 Data Description 32.2 Data Description Set Communication ConfigurationDccmdsetcomconfig Set MuteDccmdsetmute Set Output Level Adjustments33.3 DC-2/MC-1 Response 34.2 Data Description35.3 DC-2/MC-1 Response Send Display String Command34.3 DC-2/MC-1 Response 35.2 Data DescriptionInternal Use Peek CommandPoke Command Appendix a Command CodesAcknowledgments ResponsesError CodeHex Appendix B Error CodesHex Function Code Shift Functions Hex Code Rec Function Appendix C DC-2/MC-1 IR-CodesConstant ValueDec Appendix D Input Id’sAppendix E Protocol Constants Input Name Input Id15.1.1 DC-2/MC-1 Appendix F FPD Control RegistersApplication Notes and Examples Box initializationsGetting System Wide Status and Setup Downloading the System Setup to the DC-2/MC-1Simple System Control & System Status DATA0 DATA1 DATA2 DATA3 DATA4 DATA5 DATA6 DATA7 DATA8 Get Unit ConfigurationExamples SOP DLL DC CMD15.5.3 Set Input Name Get Effect DefinitionCmd Send IR Command Example