Lexicon, Inc. |
|
|
|
|
|
|
|
|
| Printed on: 10/19/00 | |||
|
|
|
|
|
| |
Application Header: |
|
|
|
| ||
Command |
| DC_CMD_GET_REC_STATUS | 0x17 |
|
| |
Data Count |
| 0 | 0x00 |
|
| |
Application Data: |
|
|
|
| ||
|
| N/A |
|
|
|
|
7.3.6.2 Record/Zone2 Status Response Packet | ||||||
|
|
|
|
| ||
Application Header: |
|
|
|
| ||
Command | DC_RESP_REC_ZONE2_STATUS | 0x82 |
| |||
Data Count | 5 |
| 0x05 |
| ||
Application Data: |
|
|
|
| ||
Data[0] | Zone2 Volume |
| nn |
| ||
Data[1] | Assigned Input |
| nn |
| ||
Data[2] | Zone2 Mute Active |
| nn |
| ||
Data[3] | Record Active |
| nn |
| ||
Data[4] | Zone2 Balance |
| nn |
|
7.3.6.3 Data Description |
|
Zone2 Volume: |
|
Data Type: | Unsigned 8 bit integer. |
Maximum Value: | 92 |
Conversion: | 0 = |
Assigned Input: | 92 = +12 dB |
| |
Indicates the input that is currently assigned for the record/zone2 outputs. | |
Data Type: | Unsigned 8 bit integer. |
Definition: | Appendix D Input Id’s |
Zone2 Active: |
|
Data Type: | Boolean. |
TRUE: | Zone2 Outputs are active. |
FALSE: | Zone2 Outputs are not active. |
Record Active: |
|
Data Type: | Boolean. |
TRUE: | Digital Record Output is active |
FALSE: | Digital Record Output is not Active. |
Zone 2 Balance: |
|
Data Type: | Unsigned 8 bit integer. |
Maximum Value: | 32 |
Conversion: | 0 = Left |
| 32 = Right |
7.3.7 Get System Parameter Definition
There are two ways to request a
7.3.7.1Get System Parameter Definition by Id Command Packet
Error! Not a valid link.
7.3.7.2Data Description
ParamId: |
|
DataType: | Unsigned 8 bit integer |
16 of 44