ABC Office DC-2, MC-1 manual Host Sleep, Get Communication Configuration, Data Description

Page 31

Lexicon, Inc.

 

DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

7.3.30 Host Sleep

By transmitting the Sleep command, the Host indicates it has just “powered down” and will no longer respond to DC-2/MC-1 Notifications. No Acknowledgment is expected.

7.3.30.1 Packet Description

Application Header:

 

Command

HOST_SLEEP

0x12

Data Count

0

0x00

Application Data:

 

 

 

N/A

 

7.3.30.2 Data Description

N/A

7.3.31 Get Communication Configuration

Request to DC-2/MC-1 for the current communications configuration for the serial port and protocol. The DC-2/MC-1 responds to this command with a Communication Configuration Packet.

7.3.31.1 Command Packet Description

Application Header:

 

Command

DC_CMD_GET_COM_CONFIG

0x2F

Data Count

0

0x00

Application Data:

 

 

 

N/A

 

7.3.31.2 System Parameter Values Response Packet

Application Header:

 

Command

DC_RESP_COM_CONFIG

0x8C

Data Count

1

0x01

Application

Data:

 

Data[0]

Configuration Register 0

nn

7.3.31.3

Data Description

Data Word

Bit

Definition

0

0

Acknowledge Enable

0

1

Parameter Change Enable

0

2

LED Acknowledge Enable

Acknowledge Enable:

TRUE

Indicates the DC-2/MC-1 will transmit Acknowledge Notification’s to

the Host.

FALSE

Indicates the DC-2/MC-1 will not transmit any positive Acknowledge

 

Notification messages. The DC-2/MC-1 will always transmit NAK error notification messages.

Parameter Change Enable: TRUE

Indicates the DC-2/MC-1 will transmit any parameter change

Notification as specified in the Parameter Change Notification Message.

Notifications.

FALSE

Indicates the DC-2/MC-1 will not transmit parameter change

 

 

31 of 44

Image 31
Contents Serial Communications Protocol Definition Data Link Layer Internal Use General Description DocumentsDefinitions AbbreviationsPhysical Layer DB-9 RS232 ConnectorSerial Port Driver Data Link Layer ErrorsDC-2/MC-1 Receive Buffer DC-2/MC-1 Hardware VerificationNotification Packet Description Application LayerDC-2/MC-1 Asynchronous Notification Packets Wakeup NotificationData Description Sleep NotificationFront Panel Display Buffer Host Response ExpectedSupported System Parameters Host ResponseAcknowledge Acknowledgment PacketsNo Acknowledge Send IR Command Host Initiated Command PacketsReset Unit Restore DefaultsData Validation Get DC-2/MC-1 Unit Configuration4.2 DC-2/MC-1 Unit Configuration Response Packet 3.3 DC-2/MC-1 ResponseSW Level Product IDSW Type THX AC3 DTSSystem Status Response Packet Get System StatusDcrespsysstatus INSTREAMAC351 Get Record/Zone 2 StatusRateunknown RATE44 RATE48 RATE88 RATE96Dccmdgetrecstatus Get System Parameter Definition by Id Command PacketGet System Parameter Definition Record/Zone2 Status Response PacketDcrespsysparamdef Get System Parameter Definition by Name Command PacketSystem Parameter Definition Response Packet DccmdgetsysparambynameEffect Definition Response Packet Get System Parameter ValuesGet Effect Definition by Id System Parameter Values Response PacketDccmdgeteffectparamdef Get Effect Parameter DefinitionEffect Parameter Definition Response Packet DcrespeffectdefApplicationHeader Get Effect Parameter Values10.5 Data Description Effect Parameter Values Response PacketGet Input Name by Id Get Custom NameData Description Custom Name Response Packet Input Name Response Packet Get FPD Control RegistersFPD Control Register Response Packet Dcrespfpdcontrol Set System Parameter ValuesSet Effect Parameter Values 15.3 DC-2/MC-1 ResponseDccmdseteffectparamvalues Set Effect Name by Effect Id16.3 DC-2/MC-1 Response 17.3 DC-2/MC-1 Response19.3 DC-2/MC-1 Response Set System VolumeSet Main Balance 18.3 DC-2/MC-1 Response20.3 DC-2/MC-1 Response Set Front/Back BalanceSet Active Effect by Id Packet Description23.3 DC-2/MC-1 Response Data Validation Set Record/Zone2 InputClear Record/Zone2 Input 22.3 DC-2/MC-1 Response Data Validation24.3 DC-2/MC-1 Response Set Zone2 VolumeSet Zone2 Left/Right Balance Set Custom NameDccmdsetcustname Set Input Name by Id26.3 DC-2/MC-1 Response 27.3 DC-2/MC-1 ResponseData Description 29.3 DC-2/MC-1 Response Set FPD Control RegistersHost Wakeup 28.3 DC-2/MC-1 ResponseHost Sleep Get Communication Configuration31.3 Data Description 32.2 Data Description Set Communication ConfigurationDccmdsetcomconfig Set MuteDccmdsetmute Set Output Level Adjustments33.3 DC-2/MC-1 Response 34.2 Data Description35.3 DC-2/MC-1 Response Send Display String Command34.3 DC-2/MC-1 Response 35.2 Data DescriptionInternal Use Peek CommandPoke Command Appendix a Command CodesAcknowledgments ResponsesError CodeHex Appendix B Error CodesHex Function Code Shift Functions Hex Code Rec Function Appendix C DC-2/MC-1 IR-CodesConstant ValueDec Appendix D Input Id’sAppendix E Protocol Constants Input Name Input Id15.1.1 DC-2/MC-1 Appendix F FPD Control RegistersApplication Notes and Examples Box initializationsDownloading the System Setup to the DC-2/MC-1 Getting System Wide Status and SetupSimple System Control & System Status DATA0 DATA1 DATA2 DATA3 DATA4 DATA5 DATA6 DATA7 DATA8 Get Unit ConfigurationExamples SOP DLL DC CMD15.5.3 Set Input Name Get Effect DefinitionCmd Send IR Command Example