Lexicon, Inc. |
|
|
|
|
| Printed on: 10/19/00 | |||
|
|
|
| |
Application Header: |
|
|
| |
Command | DC_CMD_GET_INPUT_NAME | 0x2D |
| |
Data Count | 1 |
| 0x01 |
|
Application Data: |
|
|
| |
Data[0] | InputId |
| nn |
|
7.3.13.2 Data Description |
|
| ||
InputId: |
|
|
|
|
Data Type: | Unsigned 8 bit Integer |
|
| |
Max Value: | 7 |
|
| |
Conversion: | Input Id are defined in Appendix D Input Id’s |
7.3.13.3 Data Validation:
The InputId must be a valid Input number. If it is not the
7.3.13.4 Input Name Response Packet
Application Header:
Command | DC_RESP_INPUT_NAME | 0x8A |
Data Count | strlen(InputName) + 2 | nn |
Application Data: |
|
|
Data[0] | InputId | nn |
Data[2]- | InputName | ch ch ch … 0x00 |
7.3.13.5 Data Description
InputId: |
|
Data Type: | Unsigned 8 bit Integer |
Max Value: | 7 |
Conversion: | Input Id’s are defined in Appendix D Input Id’s |
InputName: |
|
Data Type: | Null(0x00) terminated ASCII character string. |
Max Length: | INPUT_NAME_LENGTH defined in Appendix E Protocol Constants. |
7.3.14 Get FPD Control Registers
Request to
7.3.14.1 Command Packet Description
Application Header: |
| |
Command | DC_CMD_GET_FPD_CONTROL | 0x29 |
Data Count | 0 | 0x00 |
Application Data: |
| |
| N/A |
|
7.3.14.2 FPD Control Register Response Packet |
22 of 44