ABC Office MC-1, DC-2 manual Get FPD Control Registers, Input Name Response Packet

Page 22

Lexicon, Inc.

 

 

 

 

DC-2/MC-1 Serial Communications Protocol

 

Printed on: 10/19/00

 

 

 

 

Application Header:

 

 

 

Command

DC_CMD_GET_INPUT_NAME

0x2D

 

Data Count

1

 

0x01

 

Application Data:

 

 

 

Data[0]

InputId

 

nn

 

7.3.13.2 Data Description

 

 

InputId:

 

 

 

 

Data Type:

Unsigned 8 bit Integer

 

 

Max Value:

7

 

 

Conversion:

Input Id are defined in Appendix D Input Id’s

7.3.13.3 Data Validation:

The InputId must be a valid Input number. If it is not the DC-2/MC-1 will respond with a NAK packet and error code DC_ERR_ INVALID_INPUT_ID.

7.3.13.4 Input Name Response Packet

Application Header:

Command

DC_RESP_INPUT_NAME

0x8A

Data Count

strlen(InputName) + 2

nn

Application Data:

 

 

Data[0]

InputId

nn

Data[2]- Data[DataCount-1]

InputName

ch ch ch … 0x00

7.3.13.5 Data Description

InputId:

 

Data Type:

Unsigned 8 bit Integer

Max Value:

7

Conversion:

Input Id’s are defined in Appendix D Input Id’s

InputName:

 

Data Type:

Null(0x00) terminated ASCII character string.

Max Length:

INPUT_NAME_LENGTH defined in Appendix E Protocol Constants.

7.3.14 Get FPD Control Registers

Request to DC-2/MC-1 for FPD control registers. DC-2/MC-1 will respond with “FPD Control Register Packet”.

7.3.14.1 Command Packet Description

Application Header:

 

Command

DC_CMD_GET_FPD_CONTROL

0x29

Data Count

0

0x00

Application Data:

 

 

N/A

 

7.3.14.2 FPD Control Register Response Packet

22 of 44

Image 22
Contents Serial Communications Protocol Definition Data Link Layer Internal Use Abbreviations DocumentsDefinitions General DescriptionPhysical Layer DB-9 RS232 ConnectorSerial Port Driver DC-2/MC-1 Hardware Verification ErrorsDC-2/MC-1 Receive Buffer Data Link LayerWakeup Notification Application LayerDC-2/MC-1 Asynchronous Notification Packets Notification Packet DescriptionHost Response Expected Sleep NotificationFront Panel Display Buffer Data DescriptionHost Response Supported System ParametersAcknowledge Acknowledgment PacketsNo Acknowledge Restore Defaults Host Initiated Command PacketsReset Unit Send IR Command3.3 DC-2/MC-1 Response Get DC-2/MC-1 Unit Configuration4.2 DC-2/MC-1 Unit Configuration Response Packet Data ValidationTHX AC3 DTS Product IDSW Type SW LevelSystem Status Response Packet Get System StatusDcrespsysstatus RATE96 Get Record/Zone 2 StatusRateunknown RATE44 RATE48 RATE88 INSTREAMAC351Record/Zone2 Status Response Packet Get System Parameter Definition by Id Command PacketGet System Parameter Definition DccmdgetrecstatusDccmdgetsysparambyname Get System Parameter Definition by Name Command PacketSystem Parameter Definition Response Packet DcrespsysparamdefSystem Parameter Values Response Packet Get System Parameter ValuesGet Effect Definition by Id Effect Definition Response PacketDcrespeffectdef Get Effect Parameter DefinitionEffect Parameter Definition Response Packet DccmdgeteffectparamdefEffect Parameter Values Response Packet Get Effect Parameter Values10.5 Data Description ApplicationHeaderGet Input Name by Id Get Custom NameData Description Custom Name Response Packet Input Name Response Packet Get FPD Control RegistersFPD Control Register Response Packet 15.3 DC-2/MC-1 Response Set System Parameter ValuesSet Effect Parameter Values Dcrespfpdcontrol17.3 DC-2/MC-1 Response Set Effect Name by Effect Id16.3 DC-2/MC-1 Response Dccmdseteffectparamvalues18.3 DC-2/MC-1 Response Set System VolumeSet Main Balance 19.3 DC-2/MC-1 ResponsePacket Description Set Front/Back BalanceSet Active Effect by Id 20.3 DC-2/MC-1 Response22.3 DC-2/MC-1 Response Data Validation Set Record/Zone2 InputClear Record/Zone2 Input 23.3 DC-2/MC-1 Response Data ValidationSet Custom Name Set Zone2 VolumeSet Zone2 Left/Right Balance 24.3 DC-2/MC-1 Response27.3 DC-2/MC-1 Response Set Input Name by Id26.3 DC-2/MC-1 Response Dccmdsetcustname28.3 DC-2/MC-1 Response Set FPD Control RegistersHost Wakeup Data Description 29.3 DC-2/MC-1 ResponseHost Sleep Get Communication Configuration31.3 Data Description Set Mute Set Communication ConfigurationDccmdsetcomconfig 32.2 Data Description34.2 Data Description Set Output Level Adjustments33.3 DC-2/MC-1 Response Dccmdsetmute35.2 Data Description Send Display String Command34.3 DC-2/MC-1 Response 35.3 DC-2/MC-1 ResponseAppendix a Command Codes Peek CommandPoke Command Internal UseResponses AcknowledgmentsAppendix B Error Codes Error CodeHexAppendix C DC-2/MC-1 IR-Codes Hex Function Code Shift Functions Hex Code Rec FunctionInput Name Input Id Appendix D Input Id’sAppendix E Protocol Constants Constant ValueDecBox initializations Appendix F FPD Control RegistersApplication Notes and Examples 15.1.1 DC-2/MC-1Downloading the System Setup to the DC-2/MC-1 Getting System Wide Status and SetupSimple System Control & System Status SOP DLL DC CMD Get Unit ConfigurationExamples DATA0 DATA1 DATA2 DATA3 DATA4 DATA5 DATA6 DATA7 DATA8Get Effect Definition 15.5.3 Set Input NameSend IR Command Example Cmd