ABC Office DC-2, MC-1 manual Internal Use

Page 3

Lexicon, Inc.

 

DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

 

7.3.26

Set Custom Name

28

 

7.3.27

Set Input Name by Id

29

 

7.3.28

Set FPD Control Registers

30

 

7.3.29

Host Wakeup

30

 

7.3.30

Host Sleep

31

 

7.3.31

Get Communication Configuration

31

 

7.3.32

Set Communication Configuration

32

 

7.3.33

Set Mute

32

 

7.3.34

Set Output Level Adjustments

33

 

7.3.35

Send Display String Command

34

8

Internal Use

35

 

8.1.1

Debug Character

35

 

8.1.2

PEEK Command

35

 

8.1.3

POKE Command

35

9

Appendix A Command Codes

35

10

Appendix B Error Codes

37

11

Appendix C DC-2/MC-1IR-Codes

38

12

Appendix D Input Id’s

39

13

Appendix E Protocol Constants

39

14

Appendix F FPD Control Registers

40

15

Application Notes and Examples

40

 

15.1

Box initializations:

40

 

15.1.1

DC-2/MC-1:

40

 

15.1.2

HOST:

40

 

15.2

Getting System Wide Status and Setup:

41

 

15.3

Downloading the System Setup to the DC-2/MC-1:

41

 

15.4

Simple System Control & System Status:

41

 

15.5

Examples:

42

 

15.5.1

Get Unit Configuration

42

 

15.5.2

Get Effect Definition

43

 

15.5.3

Set Input Name

43

 

15.5.4

Send IR Command Example

44

3 of 44

Image 3
Contents Serial Communications Protocol Definition Data Link Layer Internal Use General Description DocumentsDefinitions AbbreviationsDB-9 RS232 Connector Physical LayerSerial Port Driver Data Link Layer ErrorsDC-2/MC-1 Receive Buffer DC-2/MC-1 Hardware VerificationNotification Packet Description Application LayerDC-2/MC-1 Asynchronous Notification Packets Wakeup NotificationData Description Sleep NotificationFront Panel Display Buffer Host Response ExpectedSupported System Parameters Host ResponseAcknowledgment Packets AcknowledgeNo Acknowledge Send IR Command Host Initiated Command PacketsReset Unit Restore DefaultsData Validation Get DC-2/MC-1 Unit Configuration4.2 DC-2/MC-1 Unit Configuration Response Packet 3.3 DC-2/MC-1 ResponseSW Level Product IDSW Type THX AC3 DTSGet System Status System Status Response PacketDcrespsysstatus INSTREAMAC351 Get Record/Zone 2 StatusRateunknown RATE44 RATE48 RATE88 RATE96Dccmdgetrecstatus Get System Parameter Definition by Id Command PacketGet System Parameter Definition Record/Zone2 Status Response PacketDcrespsysparamdef Get System Parameter Definition by Name Command PacketSystem Parameter Definition Response Packet DccmdgetsysparambynameEffect Definition Response Packet Get System Parameter ValuesGet Effect Definition by Id System Parameter Values Response PacketDccmdgeteffectparamdef Get Effect Parameter DefinitionEffect Parameter Definition Response Packet DcrespeffectdefApplicationHeader Get Effect Parameter Values10.5 Data Description Effect Parameter Values Response PacketGet Custom Name Get Input Name by IdData Description Custom Name Response Packet Get FPD Control Registers Input Name Response PacketFPD Control Register Response Packet Dcrespfpdcontrol Set System Parameter ValuesSet Effect Parameter Values 15.3 DC-2/MC-1 ResponseDccmdseteffectparamvalues Set Effect Name by Effect Id16.3 DC-2/MC-1 Response 17.3 DC-2/MC-1 Response19.3 DC-2/MC-1 Response Set System VolumeSet Main Balance 18.3 DC-2/MC-1 Response20.3 DC-2/MC-1 Response Set Front/Back BalanceSet Active Effect by Id Packet Description23.3 DC-2/MC-1 Response Data Validation Set Record/Zone2 InputClear Record/Zone2 Input 22.3 DC-2/MC-1 Response Data Validation24.3 DC-2/MC-1 Response Set Zone2 VolumeSet Zone2 Left/Right Balance Set Custom NameDccmdsetcustname Set Input Name by Id26.3 DC-2/MC-1 Response 27.3 DC-2/MC-1 ResponseData Description 29.3 DC-2/MC-1 Response Set FPD Control RegistersHost Wakeup 28.3 DC-2/MC-1 ResponseGet Communication Configuration Host Sleep31.3 Data Description 32.2 Data Description Set Communication ConfigurationDccmdsetcomconfig Set MuteDccmdsetmute Set Output Level Adjustments33.3 DC-2/MC-1 Response 34.2 Data Description35.3 DC-2/MC-1 Response Send Display String Command34.3 DC-2/MC-1 Response 35.2 Data DescriptionInternal Use Peek CommandPoke Command Appendix a Command CodesAcknowledgments ResponsesError CodeHex Appendix B Error CodesHex Function Code Shift Functions Hex Code Rec Function Appendix C DC-2/MC-1 IR-CodesConstant ValueDec Appendix D Input Id’sAppendix E Protocol Constants Input Name Input Id15.1.1 DC-2/MC-1 Appendix F FPD Control RegistersApplication Notes and Examples Box initializationsGetting System Wide Status and Setup Downloading the System Setup to the DC-2/MC-1Simple System Control & System Status DATA0 DATA1 DATA2 DATA3 DATA4 DATA5 DATA6 DATA7 DATA8 Get Unit ConfigurationExamples SOP DLL DC CMD15.5.3 Set Input Name Get Effect DefinitionCmd Send IR Command Example