TOA Electronics C-CC714 NT installation manual About Installation, Installation Method

Page 18

8. INSTALLATION

WARNING

8.1. About Installation

The Combination Camera weight 4.4 kg. Select the heavy-duty mounting surface that can structurally support the weight of the camera. Doing otherwise may result in the unit falling and possibly causing personal injury.

Mount the camera to a heavy-duty wall surface using the optional C-BC711W Wall Mounting Bracket.

When installing the camera on a pole, use the optional C-BC711W Wall Mounting Bracket, C-BC711PM Pole Mounting Bracket and 2 YS-60B Mounting Bands in combination.

Mount the camera to a heavy-duty ceiling surface using the optional C-BC711P Suspension Bracket.

Note

Perform presetting beforehand when controlling the camera using the RS-485. (refer to p.11 “Camera Settings”.)

8.2. Installation Method

The camera can be mounted on a wall, a pole or be suspended from a ceiling.

More particularly, refer to each related pages.

[ Wall mounting view ]

[ Pole mounting view ]

[ Suspension view ]

Refer to p.19

Refer to p.27

Refer to p.28

18

Image 18
Contents Installation Manual Table of Contents Safety Precautions Safety Symbol and Message ConventionsWhen Installing the Unit When the Unit is in Use Features General DescriptionHandling Precautions Modifications Housing Bottom Camera Unit Top NomenclatureCOM LED Precautions When Installing the Camera ConnectionsAbout Alarm Input Camera SettingsCamera Control Connector Connection RS-485 About AUX OutputDip Switch Settings Camera Address Setting Switch DIP Switch 1 NoCommunication Method Selector Switch DIP switch 2 No Communication Speed Setting Switch DIP switch 2 NoOSD Switch DIP switch 2 No Termination Switch DIP switch 2 NoCamera address setting switch 1 Camera address setting switch 65 Camera address setting switch 129 Camera address setting switch 193 Installation About InstallationInstallation Method Wall Mounting Bracket Installation Attaching Housing and Camera Unit to Wall Mounting Bracket Figure viewed from the top Hexagon socket screw M4 x 8 supplied with Mark Duct Page Hang Hexagon head Pole Mounting Bracket Installation Suspension Bracket Installation System Examples RS-485 Communications line controlSpecifications ATW/ AWBATW/ AWB Accessories Optional Products