6.2. Camera Control Connector Connection (RS-485)

Connect terminals (+) and (–) of the C-RM500 Remote Controller or the C-IF500 Interface Unit to the camera's terminals (+) (terminal No. 8) and (–) (terminal No. 7), respectively.

Connect the camera's terminals (+) and (–) to the next camera's terminals (+) and (–) in order.

Notes

The maximum number of units connectable to a pair of RS-485 lines (from termination to termination) is 32 units including the Remote Controller. The maximum cable length connecting each terminal is 1.2 km in total.

The camera may not operate correctly if 32 or more units are connected or the total cable distance exceeds 1.2 km. In such cases, split or extend wiring using the C-IF500 Interface Unit.

Indoor-use and outdoor-use combination cameras can be wired in free combinations.

Connect to the next cameraʼs terminal

GND

Shield twisted pair cable

Connect to remote controllerʼs camera control terminal

 

 

 

GND

 

 

 

 

 

 

Camera control

 

 

 

Camera control

 

 

 

 

 

 

cable

 

 

 

 

cable

7. CAMERA SETTINGS

7.1. About AUX Output

Open collector output,

 

Rated: withstand voltage:

30 V DC,

Permissible current:

under 100 mA

7.2. About Alarm Input

No-voltage make contact input, Rated: open voltage: 18 V DC, Short-circuit current: under 2 mA

11

Image 11
Contents Installation Manual Table of Contents When Installing the Unit Safety PrecautionsSafety Symbol and Message Conventions When the Unit is in Use General Description FeaturesHandling Precautions Modifications Nomenclature Housing Bottom Camera Unit TopCOM LED Connections Precautions When Installing the CameraAbout AUX Output Camera SettingsCamera Control Connector Connection RS-485 About Alarm InputCamera Address Setting Switch DIP Switch 1 No Dip Switch SettingsTermination Switch DIP switch 2 No Communication Speed Setting Switch DIP switch 2 NoOSD Switch DIP switch 2 No Communication Method Selector Switch DIP switch 2 NoCamera address setting switch 1 Camera address setting switch 65 Camera address setting switch 129 Camera address setting switch 193 Installation Method InstallationAbout Installation Wall Mounting Bracket Installation Attaching Housing and Camera Unit to Wall Mounting Bracket Figure viewed from the top Hexagon socket screw M4 x 8 supplied with Mark Duct Page Hang Hexagon head Pole Mounting Bracket Installation Suspension Bracket Installation RS-485 Communications line control System ExamplesATW/ AWB SpecificationsATW/ AWB Optional Products Accessories