Preparation (Step 1 Connection/Installation)
1-1 Connecting Cables (Continued)
6. Connection of Conveter Unit
Press | Power cable |
|
2. 5mm Press
1. Connector
Press
3.
to AC 24V
4.
Connect the camera to AC 24 V.
1. Disconnect the connector from the sup- plied Converter Unit.
It can be disconnected by pressing both ends as shown in the left figure.
2. Mount the power cable to the connector. Strip the cover of the power cable (about 5 mm), while pressing down the arrow portion using a flat screwdriver, insert it into the con- nector.
3. Mount the connector.
4. Connect the supplied Converter Unit to the DC 18V input terminal on the terminal stand.
When a
Maximum cable length | 70 m | 180 m | 280 m | 480 m |
Wire diameter (mm) | 1.0 or more | 1.6 or more | 2.0 or more | 2.6 or more |
|
|
|
|
|
Caution
¥Connect with the appropriate
If a voltage exceeding the rating is supplied, malfunction, or in the worst case, fuming or fire, may be caused.
¥Installation shall be performed by qualified personnel according to regulations of individual regions.
Notes
Connecting multiple VN-C655 Cameras
In a system where more than 1
¥Default IP address setting for all
¥When IP address redundancy occurs, ensure that only one