JVC VN-C655 manual Important Safeguards

Page 3
PORTABLE CART WARNING (symbol provided by RETAC)
S3125A

These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances.

IMPORTANT SAFEGUARDS

1.Read all of these instructions.

2.Save these instructions for later use.

3.All warnings on the product and in the operating instructions should be adhered to.

4.Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

5.Do not use attachments not recommended by the appliance manufacturer as they may cause hazards.

6.Do not use this appliance near water - for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, etc.

7. Do not place this appliance on an unstable cart, stand, or table. The appliance may fall, causing serious injury to a child or adult, and serious damage to the appliance. Use only with a cart or stand recommended by the manufacturer, or sold with the appliance. Wall or shelf mounting should follow the manufacturerÕs instructions, and

should use a mounting kit approved by the manufacturer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.

8. Slots and openings in the cabinet and the back or bottom are pro-vided for ventila- tion, and to insure reliable operation of the appliance and to protect it from over-

heating, these openings must not be blocked or covered.The openings should never be blocked by placing the appliance on a bed, sofa, rug, or other similar surface.

This appliance should never be placed near or over a radiator or heat register. This appliance should not be placed in a built-in installation such as a bookcase unless proper ventilation is provided.

9.This appliance should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied to your home, consult your dealer or local power company. For appliance designed to operate from battery power, refer to the operating instructions.

10.This appliance system is equipped with a 3-wire grounding type plug (a plug having a third (grounding) pin). This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding plug.

11.For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it form the wall outlet and disconnect the antenna or cable system. This will prevent damage to the product due to lightning and power-line surges.

12.Do not allow anything to rest on the power cord. Do not locate this appliance where the cord will be abused by persons walking on it.

13.Follow all warnings and instructions marked on the appliance.

14.Do not overload wall outlets and extension cords as this can result in fire or electric shock.

15.Never push objects of any kind into this appliance through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the appliance.

16.Do not attempt to service this appliance yourself as opening or removing covers may expose you to danger- ous voltage or other hazards. Refer all servicing to qualified service personnel.

17.Unplug this appliance from the wall outlet and refer servicing to qualified service personnel under the follow- ing conditions:

a.When the power cord or plug is damaged or frayed.

b.If liquid has been spilled into the appliance.

c.If the appliance has been exposed to rain or water.

d.If the appliance does not operate normally by following the operating instructions. Adjust only those con- trols that are covered by the operating instructions as improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the appliance to normal operation.

e.If the appliance has been dropped or the cabinet has been damaged.

f.When the appliance exhibits a distinct change in performance - this indicates a need for service.

18.When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer that have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards.

19.Upon completion of any service or repairs to this appliance, ask the service technician to perform routine safety checks to determine that the appliance is in safe operating condition.

3

Image 3
Contents VN-C655 Information for USA Safety PrecautionsImportant Safeguards Preparation Settings Contents IntroductionOperation Setting Using the V.Networks ControllerOperating Using the V.Networks Controller Operating Using a Web BrowserCharacteristics Operating PrecautionsIntroduction  Zooming operation  Consumable PartsOperating Precautions Operating Environment Latest UpdatesPC Specifications Items IncludedAlarm I/OAlarm Input/Output Terminals Pin No Signal NameName and Function of Parts Drop Prevention Hook # Lens Camera Terminal Male Drop Prevention WireCeiling MountCamera Camera Terminal Female @ Dome CoverPeer-to-Peer Connection Connection ExamplesLAN Connection Network ConnectionSet the camera in the following procedure Preparation ProcedureConnect the cables Connecting CablesLan cable Alarm signal cable Coaxial cable Converter Unit Making the holeConnection to Alarm Input/Output Terminal Cable SpecificationsInput Requirements Preparation Connection/Installation Connection of LAN CablesOutput Requirements Connection of Coaxial Cables Connecting a 5C-2V or 3C-2V coaxial cableConnection of Conveter Unit Connecting CablesDisconnect the connector from the sup- plied Converter Unit Connecting multiple VN-C655 CamerasAttach safety wire to prevent camera from falling down Attachment of Ceiling MountCeiling Mount Ceiling structure. If the ceiling structure is Installing the Camera Installing the Camera Turn the cameraFasten the locking screw Installing the VN-C655U Setup Tool Installing the SoftwareFollowing procedure from the CD-ROM supplied Installing the V.Networks ControllerSetting PCs IP Address Windows XP Settings Network SettingsClick Click on the Local Area Connection Properties screen Select Internet Protocol TCP/IP and click PropertiesSetting PCs IP Address Windows Click Settings Network Settings Start up the V.Networks Controller. Check settingsOther Settings Using the VN-C655U Setup Tool Following confirmation screen will be displayed Authorization Level Allowed AccessMulticast Other Settings Using the VN-C655U Setup Tool 2. MulticastSearch result is displayed Start up the VN-C655U Setup ToolV.Networks Search screen is displayed Multicast Address Search screen is displayedStart up the VN-C655U Setup Tool and select Alarm This section describes procedures for alarm settingAlarm Input Operation when an alarm input is activatedPage Go to a preset Alarm 1/AlarmDetect Mode Alarm OutputAvailable Alarm 1/Alarm Message PacketAlarm FTP Relay AlarmPreset Position Position Return ModeMotion Detection  Alarm Output Setting the Trigger Recording screen Setting the Frame Rate screenExample Setting the Advance screen Recording timeRecording files When all the settings have been completed, click to end Start up the VN-C655U Setup Tool and select Private MaskFree area Fixed areaPerform area setting Displaying still images uploaded to the /user folder Other Settings Using the VN-C655U Setup Tool 7. WebStart up the VN-C655U Setup Tool and select FTP Server Other Settings Using the VN-C655U Setup Tool 8. FTP Server¥ Rec File ¥ Alarm FTPContinuous FTP Trigger FTPAlarm FTP Upload Setting PasswordError recovery Connection error Transfer errorTime Mode Black and WhiteOne Push AF Auto LevelLight When NTP is used Start up the VN-C655U Setup Tool and select TimeStart up the VN-C655U Setup Tool and select Memory Info NormalHigh Speed Connect to VN-C655 Starting Up V.Networks Controller Settings Setting Using the V.Networks ControllerFeatures that Allow Setting Using the V.Networks Controller Frame rate Settings Setting Using the V.Networks ControllerFeatures that Allow Setting Using the V.Networks Controller 4Setting QualitySelect File and Motion Detection Standby Select a camera Motion Detection StandbyOperations Setting Using the V.Networks Controller Select View Specify Image Size and Upside Down settingsImage Size and Inversion Image Quality Setting Image Quality Setting  Image Quality Setting Set value Auto Black ControlAverage Peak Large Peak valueExDR Mode Sense UpExDR Level Sharpness Setting values -5 toImage Quality Setting  Lens Frame Rate Select Setting and Frame rate Set the Frame RateSelect Setting and Position Memory Preset Position SettingWhen setting is complete, click Alarm SettingAlarm Setting Pan/Tilt Setting Select Setting and Auto Pan Setting Auto Pan SettingClose the window Perform settingSelect Setting and Auto Patrol Setting Auto Patrol SettingAuto Patrol No Auto Trace Setting Select Setting and Auto Trace SettingStart to memorize operation Close the window Time Stamp Select Setting and Time Stamp Perform settingSelect Setting and Property Perform setting When alteration is complete, clickChanging Registered Information Snap Shot Buttons for position movingReduced Screen # Pan/Tilt/Zoom Position Indicator Pan/Tilt button@ Size Click the Stop button Operations Operation Using the V.Networks ControllerRecord/Stop Click the REC buttonPlayback Playback Click Playback screen is displayed Image Size Data Size Per Image Approximate Recording Time Record/Playback TimeSave As screen is displayed SnapshotClick the Snap Shot button Snap screen will be displayedWeb Page Images LAN EnvironmentAccess Authorization Level Operations Operating Using a Web BrowserAuthentication of Access Authorization Starting Up the Web Browser Start up the web browserTop page will be displayed Setting Using the Web Browser Display the TopTop Settings page will be displayed Other settings Setting Using the Web Browser 1. Other SettingsDefault Description of Items in Other Settings MeaningDefault Gateway Administrator LevelSetting Using the Web Browser 1. Other Settings Http port number, check using the setup tool supplied# NTP Settings Setting Using the Web Browser 2. Control Operations Setting Using the Web Browser Setting Using the Web Browser 3.Image Setting$ White Balance # Iris ModeAGC @ Manual Focus LevelSetting Using the Web Browser 3.Image Setting According to ZOOM, speed of operation is Setting Using the Web Browser 4. PAN/TILT SettingPAN/TILT Speed Auto Flip 1Low, 2 to 7, 8FastImage Settings Screen Setting Using the Web Browser 5. Position Memory SettingResolution Setting Using the Web Browser 6. View Setting100 Setting Using the Web Browser 7. Alarm Setting Alarm  Alarm Out Other Triggers 102 Setting Using the Web Browser 8. FTP SettingOn connect error Retry forever Still image FTP, Same as Alarm FTP JpgSpecify a recovery action when errors related to FTP occur Error RecoverySetting Using the Web Browser 9. Auto Pan Setting 105 Setting Using the Web Browser 10. Auto Patrol SettingPosition Number Duration106 Setting Using the Web Browser 11. Auto Trace SettingRecord Start Confirmation Screen Image Setting Screen For setting image qualitySetting Using the Web Browser 12. Black & White Setting Setting Using the Web Browser 13. Schedule Setting107 Mask Position and Size Controller 108 Setting Using the Web Browser 14. Private Mask Setting109 Viewing Still Images110 Viewing Live ImagesImage Link Displaying a still image111 Troubleshooting Symptom Causes/Remedial Actions112 113 Specifications  Ceiling Mount Hole Unit mm inches  External Dimensions Unit mm inchesDome Type Network Camera VN-C655