Operations (Step 3 Setting Using the V.Networks Controller)
3-5 Image Quality Setting (Continued)
Image Quality Setting (Continued)
Item | Function/Set Value | Initial Value |
|
|
|
Sense Up | This function is used to increase the sensitivity by extending | OFF |
| the exposure time. Increasing this value slows the shutter speed |
|
| and motion may appear unnatural. |
|
| When the item "SHUTTER" is set to "1/250" or more, the |
|
| SENSE UP item does not work. |
|
| Setting values: OFF, x2, x4, x8, x16, x24, x32 |
|
| • When SENSE UP is activated, the picture may become rough |
|
| and whitish, and subject to white blemishes. |
|
| • When the setting of the "SENSE UP" function is not OFF, |
|
| flicker may appear on the screen under fluorescent light or |
|
| mercury lamps. This is due to the principles of the SENSE |
|
| UP, and is not a malfunction. |
|
| • There may be cases where flicker can not be reduced even |
|
| under the following conditions: 1) Shutter speed is set at 1/100 |
|
| in areas where the commercial electric current frequency is 60 |
|
| Hz. 2) The shutter speed is set at 1/60 in areas where the com- |
|
| mercial electric current frequency is 50 Hz. |
|
|
|
|
ExDR Mode | The ExDR function synthesizes pictures captured at a shutter | OFF |
| speed of 1/100 and those captured at higher shutter speeds to |
|
| help monitor objects having large differences in brightness lev- |
|
| els. |
|
| When the "SHUTTER" function is set to "1/250" or a higher, |
|
| this function does not work. |
|
| OFF : Turns the ExDR function off. |
|
| ON : Turns the ExDR function on. |
|
| • When the ExDR function is on, flicker may appear on the |
|
| screen under fluorescent light or mercury lamps. This is due |
|
| to the principles of the ExDR, and is not a malfunction. |
|
| • There may be cases where flicker cannot be reduced even |
|
| under the following conditions: 1) Shutter speed is set at 1/ |
|
| 100 in areas where the commercial electric current frequency |
|
| is 60 Hz. 2) The shutter speed is set at 1/60 in areas where |
|
| the commercial electric current frequency is 50 Hz. |
|
|
|
|
ExDR Level | This function sets which section of the object is to be displayed | 0 |
| in the |
|
| brightness level in the ExDR mode. |
|
|
|
|
62