1.4.How to Discharge the E.Capacitor on Flash Top P.C.B.
CAUTION:
•Be sure to discharge the E.Capacitor on Flash Top P.C.B. before disassembling.
•Be careful of the high voltage circuit on Flash Top P.C.B. when servicing.
[Discharging Procedure]
1.Put the insulation tube on the lead part of resistor (ERG5SJ102:1kΩ /5W). (An equivalent type of resistor may be used.)
2.Put the resistor between both terminals of E.Capacitor on the Flash Top P.C.B. for approx. 5 seconds.
3.After discharging, confirm that the E.Capacitor voltage is lower than 10V by using a voltmeter.
Fig. F1
4