Panasonic DMCXS1K manual Measurements and Adjustments, Introduction, Before Disassembling the unit

Page 29

9 Measurements and Adjustments

9.1.Introduction

When servicing this unit, make sure to perform the adjustments necessary based on the part(s) replaced.

Before disassembling the unit, it is recommended to back up the camera data stored in Flash-ROM as a data file.

IMPORTANT NOTICE (After replacing the Main P.C.B.)

After replacing the Main P.C.B., it is necessary to use the “DIAS” software to allow the release of adjustment flag(s). The Adjustment software “DIAS” is available at “TSN Website”.

*DIAS (DSC Integrated Assist Software)

NOTE: (When replacing the Lens unit and CCD FPC unit)

When the CCD FPC unit is unavoidably removed for Lens unit and CCD FPC unit replaced, an optical tilt adjustment is neces- sary after parts are exchanged.

The adjustment software (DSC_Tilt) is necessary to execute an optical tilt adjustment.

The adjustment software “DSC_Tilt” is available at “TSN Website”.

NOTE: (When replacing the Main P.C.B.)

Number of necessary adjustment items decreases by copying the backup data to new Main P.C.B. when adjustment data in old Main P.C.B. can be read by ROM_BACKUP “DSCSD” in “9.2.2. Flash-ROM Data Backup”.

For more details, please refer an item “Main P.C.B. (to which the backup data was copied)” in the table of “9.3.2. Adjustment Specifications”.

9.2.Before Disassembling the unit

9.2.1.Initial Setting Release

The cameras specification are initially set in accordance with model suffix (such as EB/EG/GK/GC and so on.).

Unless the initial setting is not released, an automatic alignment software in the camera is not able to be executed when the align- ment is carried out.

Note:

The initial setting should be again done after completing the alignment. Otherwise, the camera may not work properly. Therefore as a warning, the camera display a warning symbol “ ! ” on the LCD monitor every time the camera is turned off. Refer to the procedure described in “3.4.2. INITIAL SETTINGS” for details.

[ How to Release the camera initial setting ] Preparation:

• Attach the Battery.

(Since this unit has built-in memory, it can be performed without inserting memory card.)

1.Turn the Power on.

2.Press the [ MODE ] button, and select the [ NORMAL PICTURE ] mode by Cursor buttons, then press the [ MENU/SET ] but- ton.

3.Turn the Power off.

(If the unit is other than [ NORMAL PICTURE ] mode, it does not display the initial settings menu.)

Step 1. The temporary cancellation of “INITIAL SETTINGS”:

Press the [ PLAYBACK ] button ,“[ UP ] of Cursor button” and “[ W ] side of Zoom button” simultaneously, turn the Power on.

Step 2. Cancellation of “INITIAL SETTINGS”:

Press the [ PLAYBACK ] button in order to enter the [ PLAYBACK ] mode.

Press the [ MENU/SET ] button and “[ LEFT ] of Cursor button” simultaneously, turn the Power off.

The LCD displays the “ ! ” mark before the unit powers down.

29

Image 29
Contents Model No. DMC-XS1P Table of Contents General Guidelines Safety PrecautionsLeakage Current Cold Check Leakage Current Hot Check See FigureFig. F1 How to Discharge the E.Capacitor on Flash Top P.C.BHow to Recycle the Lithium Ion Battery U.S. Only Introduction Important Notice Service NavigationGeneral Description About Lead Free Solder PbF Recommended Lead Free Solder Service Parts RouteDefining methods How to Define the Model Suffix Ntsc or PAL modelTurn the Power on Turn the Power on Temporary cancellation of Initial SettingsCancellation of Initial Settings Choose the model suffix in Initial Settings Refer to Caution Display the Initial SettingConfirmation Default setting After Initial SettingsSpecifications Location of Controls and Components Page Error Code Memory Function Service ModeHow to display Execute the error code display modeError Code List About ? indication 18*0 0?01 to 18*0 0?60 Important notice about Error Code List About * indicationHow to exit from Error Code display mode When Replacing the Main P.C.B Service Fixture & ToolsService Fixture and Tools Service Position P.C.B. Location Disassembly and Assembly InstructionsDisassembly Flow Chart Removal of the Rear Case Unit Disassembly ProcedureFig. D2 Removal of the Rear Op Plate UnitFig. D4 Removal of the Front Case Unit Removal of the LCD UnitRemoval of the Top Case Unit Removal of the Frame PlateSpeaker Removal of the Main P.C.B.Fig. D12 Fig. D13 Removal of the Battery Door UnitFig. D14 Removal of the CCD FPC UnitInitial Setting Release Measurements and AdjustmentsIntroduction Before Disassembling the unitLight Box Flash-ROM Data BackupRombackup Method of Non-PC backup How to execute the Electrical Adjustment Details of Electrical AdjustmentStartup Electrical Adjustment mode Status Adjustment Flag SettingFinalizing the Adjustment Execute Adjustment Case of OIS AdjustmentAdjustment Specifications Page Initial Setting After AdjustmentCleaning Lens and LCD Panel MaintenanceOverall Block Diagram Block DiagramSub Operation Block Diagram Flash / Top Block DiagramInterconnection Diagram Wiring Connection Diagram