Panasonic DMC-XS1GK Temporary cancellation of Initial Settings, Cancellation of Initial Settings

Page 9

3.4.2.INITIAL SETTINGS:

After replacing the Main P.C.B., make sure to perform the initial settings after achieving the adjustment by ordering the following procedure in accordance with model suffix of the unit.

1. IMPORTANT NOTICE:

Before proceeding Initial settings, make sure to read the following CAUTIONS.

2.PROCEDURES:

Precautions: Read the above “CAUTION 1” and “CAUTION 2”, carefully.

Preparation:

-Attach the Battery.

(Since this unit has built-in memory, it can be performed without inserting memory card.)

1.Turn the Power on.

2.Press the [ MODE ] button, and select the [ NORMAL PICTURE ] mode by Cursor buttons, then press the [ MENU/SET ] button.

3.Turn the Power off.

(If the unit is other than [ NORMAL PICTURE ] mode, it does not display the initial settings menu.)

Step 1. The temporary cancellation of “INITIAL SETTINGS”:

Press the [ PLAYBACK ] button, “[ UP ] of Cursor button” and “[ W ] side of Zoom button” simultaneously, turn the Power on.

Step 2. The cancellation of “INITIAL SETTINGS”:

Press the [ PLAYBACK ] button in order to enter the [ PLAYBACK ] mode.

Press the [ MENU/SET ] button and “[ LEFT ] of Cursor button” simultaneously, turn the Power off. The LCD displays the “ ! ” mark before the unit powers down.

Step 3. Turn the Power on: Turn the Power on.

9

Image 9
Contents Model No. DMC-XS1P Table of Contents General Guidelines Safety PrecautionsLeakage Current Cold Check Leakage Current Hot Check See FigureFig. F1 How to Discharge the E.Capacitor on Flash Top P.C.BHow to Recycle the Lithium Ion Battery U.S. Only Introduction Important Notice Service NavigationGeneral Description About Lead Free Solder PbF Recommended Lead Free Solder Service Parts RouteDefining methods How to Define the Model Suffix Ntsc or PAL modelTemporary cancellation of Initial Settings Cancellation of Initial SettingsTurn the Power on Turn the Power on Choose the model suffix in Initial Settings Refer to Caution Display the Initial SettingConfirmation Default setting After Initial SettingsSpecifications Location of Controls and Components Page Error Code Memory Function Service ModeHow to display Execute the error code display modeError Code List Important notice about Error Code List About * indication How to exit from Error Code display modeAbout ? indication 18*0 0?01 to 18*0 0?60 Service Fixture & Tools Service Fixture and ToolsWhen Replacing the Main P.C.B Service Position Disassembly and Assembly Instructions Disassembly Flow ChartP.C.B. Location Removal of the Rear Case Unit Disassembly ProcedureFig. D2 Removal of the Rear Op Plate UnitFig. D4 Removal of the Front Case Unit Removal of the LCD UnitRemoval of the Top Case Unit Removal of the Frame PlateSpeaker Removal of the Main P.C.B.Fig. D12 Fig. D13 Removal of the Battery Door UnitFig. D14 Removal of the CCD FPC UnitInitial Setting Release Measurements and AdjustmentsIntroduction Before Disassembling the unitFlash-ROM Data Backup Rombackup Method of Non-PC backupLight Box How to execute the Electrical Adjustment Details of Electrical AdjustmentStartup Electrical Adjustment mode Status Adjustment Flag SettingFinalizing the Adjustment Execute Adjustment Case of OIS AdjustmentAdjustment Specifications Page Initial Setting After AdjustmentCleaning Lens and LCD Panel MaintenanceOverall Block Diagram Block DiagramSub Operation Block Diagram Flash / Top Block DiagramInterconnection Diagram Wiring Connection Diagram