AXIS Q6045–S PTZ Dome Network Camera
Hardware Overview
Hardware Overview
1Mounting hole for sunshield (3x)
2Pressure relief valve
3Multiconnector
4Hook for safety wire
5Guide hole
6Inlet valve
7Mounting hole (3x)
8Part number (P/N) & Serial number (S/N)
9SD card slot (SDHC)
10Status LED indicator
11Control button
Pressurize the Camera (Recommended)
The camera housing can be filled with Nitrogen gas to prevent condensation.
The filling process is repeated three times, releasing the pressure between fillings, to make sure that all air and humidity is purged from the housing.
Note
The camera housing has an pressure relief valve that limits the filling pressure to 0.5 bar (7 psi). During normal use the pressure inside the camera housing may drop below that pressure. For full protection make sure that the pressure is above
0.2bar (3 psi) .
1.Set the regulator gauge on the gas cylinder to 0.5 bar (7 psi).
2.Remove the caps from the inlet valve and the pressure relief valve.
3.Place the chuck on the inlet valve and press down to fill the camera with nitrogen.
4.When the pressure inside the camera housing reaches 0.5 bar (7 psi) the pressure relief valve will open. Place your hand over the pressure relief valve to verify that the gas is flowing out.
6