AXIS Q6044-C PTZ Dome Network Camera

PTZ (Pan Tilt Zoom)

Configure the near focus limit to avoid focusing on objects too close to the camera lens.

When Enable E-flipis selected, as it tilts down and continues to pan backwards, the Axis product will automatically correct the view and flip it 180 degrees. The left limit must be set to –180 degrees and the right limit to 180 degrees for e-flip to work.

Move speed sets the speed of the camera’s pan and tilt movements. The default setting is maximum speed.

When using a joystick (or emulating one with the mouse) the Enable proportional speed setting can be used to reduce the maximum pan/tilt movement speed, i.e. the speed the camera view moves at when the joystick is pushed all the way out in any direction. This is useful then the view is zoomed in on an object.

See the online help for more information.

Controls

Advanced PTZ settings can be configured under PTZ > Advanced > Controls.

The Panel Shortcut Command Buttons list shows the user-defined buttons that can be accessed from the Live View page’s Ctrl panel. These buttons can be used to provide direct access to commands issued using the VAPIX® application programming interface. Click Add to add a new shortcut command button.

The following PTZ controls are enabled by default:

Pan control

Tilt control

Zoom control

Focus control

Iris control

To disable specific controls, deselect the options under Enable/Disable controls.

Note

Disabling PTZ controls will not affect preset positions. For example, if the tilt control is disabled, the product can still move to preset positions that require a tilt movement.

Control Queue

The administrator can set up a queue for PTZ controllers from PTZ > Control Queue. Once set up, the PTZ Control Queue buttons appear in the Live View page offering one viewer exclusive control for a limited period of time. Other users will be placed in queue.

A user who belongs to a group (see Users on page 44) with a higher PTZ priority can go before other users in the queue and take control of the product. The order of priority is as follows:

1.Administrator — An administrator takes over PTZ control regardless of who is first in queue. The administrator will be removed from the queue 60 seconds after the last PTZ control command.

2.Event — The Axis product can be configured to go to a preset position when triggered by an alarm (see Events on page 37). The event will immediately be placed first in the queue except when an administrator is in control.

3.Operator — Same as administrator but with lower priority

4.Guard Tour — A guard tour (see page 29) has PTZ control for an indefinite period of time. It may be overridden by an operator, event or administrator. The guard tour will resume when higher priority groups leave the queue.

5.Viewer — Multiple viewers must wait for their turn. The viewer has 60 seconds PTZ control before control is passed on to the next viewer in queue.

31

Image 31
Contents Axis Q6044-C PTZ Dome Network Camera Intellectual Property Rights About this DocumentLegal Considerations LiabilityLearn More SupportAxis Q6044-C PTZ Dome Network Camera Table of ContentsMulti-Connector Cable Troubleshooting Camera Connectors and ButtonsFor technical specifications, see Hardware OverviewSD Card Slot LED IndicatorsMulti-connector Power ButtonMedia Converter Switch Connectors Media Converter SwitchDip switch position Network Connector Dip SwitchesConnector internal 2-pin I/O terminal block Description Media Converter Switch LED IndicatorsSet the Root Password Access the ProductAccess from a Browser Access from the InternetClick Use Https Go to Setup EventsLive View Controls on the Live ViewPTZ Controls Axis Media Control viewer toolbarTo show the manual trigger buttons in the Live View Axis Q6044-C PTZ Dome Network Camera Media Streams How to Stream H.264Axis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis Q6044-C PTZ Dome Network Camera Basic Setup Set Up the ProductVideo Stream VideoPixel Counter Image Click Save to apply the new settings264 Stream Profiles Camera SettingsOverlay Image SettingsGo to Video Video Stream and select the Image tab Use Overlay Text in an Action Rule Overlay ImageGo to Video Overlay Image Start by enabling overlay text in the video stream Privacy MaskGo to Events Action Rules Browser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsFor more information about I/O ports, see I/O Ports on Go to Setup Live View ConfigUser Defined Links Output ButtonsPTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions Click Add to save the preset positionExclude Areas ConfigurationGatekeeper AutotrackingMax Limits Guard TourTo add a guard tour Limits Osdi ZonesAdvanced Tour RecordingControl Queue Operator Same as administrator but with lower priorityControls Axis Q6044-C PTZ Dome Network Camera Motion Detection Set Up Motion Detection WindowsDetectors Shock DetectionMedium level 50% Default valuesParameter Object Size History Sensitivity Description High level 100%Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis Q6044-C PTZ Dome Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents TriggersActions Recipient Types Add RecipientsGo to Events Schedules and click Add Set Up RecurrencesSet Up Email Recipients Create SchedulesAxis Q6044-C PTZ Dome Network Camera Go to Recordings List RecordingsRecording List Continuous RecordingLanguages IP Address Filter System OptionsSecurity UsersCertificates IeeeGo to System Options Security Ieee Network Basic TCP/IP SettingsGo to Setup System Options Security Certificates Date & TimeARP/Ping IPv4 Address ConfigurationIPv6 Address Configuration Assign IP Address Using ARP/PingDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service Axis Internet Dynamic DNS Service requires IPv4NAT traversal port mapping for IPv4 NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressSmtp email QoS Quality of ServiceBonjour UPnPTM can be disabled under System Options Network UPnPTMUPnPTM RTP/H.264Format SD Card StorageSD Card Mount and Unmount SD CardPorts MaintenancePorts & Devices Network ShareLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsPlain Config ScriptingAxis Q6044-C PTZ Dome Network Camera Green/white Ethernet receiving Multi-Connector CableFunction Pin wire Specifications Activated, floating unconnected when Drain, 100 mACheck the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserKey frames Problems with streaming H.264Video and image problems, general Video Camera SettingsRe-mount the storage device Storage and disk management problemsMedia converter switch Storage disruptionTechnical Specifications Power Function/group Specifications System ApplicationInstallation aid MaintenanceCamera Connectors ConnectorsTerminal connector External ConnectorsFunction Pin Specifications Network connectorPerformance Considerations M5.2