16 en
2.7 Alarm I/O Setup
The Alarm Setup Menu provides access to the Alarm I/O Setup Menu to establish the alarm inputs and outputs and to configure alarm rules.
Alarm I/O Setup
Exit...
Inputs Setup...
Outputs Setup...
Rule Setup...
Restore Defaults...
Focus / Iris: Select
Alarm Setup Menu Choices:
| Inputs Setup |
|
Exit... |
| |
1. | Alarm Input 1 | N.C.S. |
2. | Alarm Input 2 | N.O.S. |
3. | Alarm Input 3 | N.O. |
4. | Alarm Input 4 | N.C. |
5. | Alarm Input 5 | N.O. |
6. | Alarm Input 6 | N.C. |
7. | Alarm Input 7 | N.O. |
8. | NONE |
|
9. | NONE |
|
10. NONE
11. NONE
12. NONE
Focus / Iris: Select Type
Right / Left: Select Mode
Menu | Description | Default | |
|
|
| Setting |
|
|
|
|
Exit | Saves and exits the menu. |
|
|
|
|
|
|
Inputs Setup | Defines physical inputs or events and |
|
|
| commands that can be used in a rule. |
|
|
| There are twelve (12) alarm inputs |
|
|
| available. |
|
|
|
|
|
|
Inputs | Defines the type of physical input. | N.O.: Normally open dry contact. | N.O. |
|
| N.C.: Normally closed dry contact. |
|
|
| N.C.S.: Normally closed supervised contact. |
|
|
| N.O.S.: Normally open supervised contact. |
|
|
|
|
|
Inputs | Defines input commands that can be | NONE: No command defined. | NONE |
| used in a rule. Command inputs can | Aux On: Programs a standard or custom key- |
|
| also be customized by using non- | board ON |
|
| assigned keyboard command num- | Aux Off: Programs a standard or custom |
|
| bers. | keyboard OFF |
|
|
| Shot: Programs a Preset shot or scene from |
|
|
|
| |
|
| AutoTrack: Triggers an alarm when set to |
|
|
| ON. (Available with 500i Series only). |
|
|
| Motion Detection: Triggers an alarm when |
|
|
| set to ON. (Available with 500i Series only). |
|
|
|
|
|
NOTICE! Alarm inputs 1 and 2 provide tamper detection, if programmed as supervised, for
i breaks or shorts in an alarm circuit. See the AutoDome Modular Camera System Installation Manual for wiring instructions.
F01U064036 1.1 2007.01 | Bosch Security Systems, Inc. |