50 en Troubleshooting GuideAutoDome Modular Camera System
No camera control | 1. | Ensure that the keyboard and monitor are set to the correct (same) camera number. | |
|
| If O.K., then: |
|
| 2. | Check that the camera address is properly set. Enter | |
|
| era address. |
|
| If address is not set or is incorrect, then: | ||
| 3. | Set the camera address using FastAddress | |
|
| If O.K., then: |
|
| 4. | Check that the Amber LED on the AutoDome CPU turns on when receiving pan/tilt com- | |
|
| mands from the controller keyboard. The Amber LED indicates control is being | |
|
| received. |
|
|
| Amber LED on AutoDome CPU Module | |
|
| Flash Sequence | Indicates: |
|
| Off | No incoming communications or no power |
|
| Solid for 2 seconds | Receiving good data |
|
| Fast blinking | Lost packet(s) |
| If amber LED does not light when given PTZ commands, then: | ||
| 5. | Check if other cameras on the system can be controlled. If not, check the controller and | |
|
| wiring connections. |
|
|
| If O.K., then: |
|
| 6. | Check that the | |
|
| If O.K., then: |
|
| 7. | Ensure that all Biphase, Bilinx, or | |
|
| AutoDome Modular Camera System Installation Manual. | |
|
| If O.K., then: |
|
| 8. | Check if you can access the AutoDome OSD menus | |
|
| If O.K., then: |
|
| 9. | Confirm that the AutoDome passes homing | |
| If AutoDome fails homing, then: |
| |
| 10. | Contact Bosch Technical Support. | |
|
|
| |
Intermittent camera | 1. | Check that only the last AutoDome in a daisy chain configuration is terminated with a | |
control |
| 110 Ω resistor across the +/- biphase terminals. | |
| If O.K., then: |
| |
| 2. | Check that the maximum wire distance has not been exceeded for the control protocol | |
|
| (the maximum distance for | |
|
| tem Installation Manual. |
|
| If O.K., then: |
| |
| 3. | Check that all wiring meets Bosch recommended standards and specifications. See the | |
|
| AutoDome Modular Camera System Installation Manual. | |
|
|
| |
Camera moves when | 1. | Check that the camera address is properly set | |
moving other cam- |
| is not set, the AutoDome responds to control commands to any camera on the system. | |
eras | If camera address is not set, then: | ||
| 2. | Invoke the FastAddress Menu to assign a camera address | |
|
|
| |
Cannot access user | X | Enter the unlock command | |
settings |
| (Commands automatically lock in 30 minutes.) | |
|
|
|
|
F01U064036 1.0 2007.01 | Bosch Security Systems, Inc. |