Bosch Appliances VG4-500I, VG4-200 Setting the Camera Address, Keyboard Commands, FastAddress

Page 8

4

en Getting Started

AutoDome Modular Camera System

 

 

 

1.2.2Keyboard Commands

Keyboard control commands are composed of a sequence of three (3) inputs with the follow- ing convention: 1) a Function key + 2) a Command number key(s) + 3) the Enter key.

Depending on the type of keyboard, the control function keys are labeled: ON or AUX ON

OFF or AUX OFF SET or SET SHOT SHOT or SHOW SHOT

i

NOTICE! The convention used for control key commands in this manual is ON, OFF, SET, and

SHOT. Refer to your keyboard manual for the key naming conventions.

 

Command numbers range from 1 to 999. See Chapter 6: Keyboard Commands by Number for a complete list of keyboard commands.

The Enter key can also be labeled with the  symbol.

 

For example, the keyboard command to make the AutoDome pan 360º continuously is:

 

 

ON-1-ENTER

 

 

Press the ON key, then press the number 1 key, and then press ENTER.

 

1.3

Setting the Camera Address

 

 

Once the AutoDome power is turned on and homing is complete, you must set the camera

 

 

address. You may also want to assign a password and customize some of the AutoDome

 

 

default settings.

 

 

 

 

i

NOTICE! You do not need to set a camera address if using Bilinx or Ethernet communication.

 

See the AutoDome Installation Manual to configure an AutoDome for Bilinx or Ethernet

 

operation.

 

 

 

 

1.3.1

FastAddress

 

 

FastAddress is an AutoDome feature that allows you to set or change a camera address using

 

 

the keyboard and on-screen menus.

 

 

There are three (3) FastAddress commands:

 

 

ON-999-ENTER: Displays and programs all cameras without an address in the system.

 

 

 

 

i

NOTICE! If a keyboard is set to a camera number that already has an address, that camera also

 

responds to this command.

 

 

 

ON-998-ENTER: Displays and programs all cameras with or without an address in the sys- tem.

ON-997-ENTER: Displays the current address status of all cameras in the system simulta- neously.

To set an address to a camera without an address:

1.Select the camera number you want to FastAddress. The system displays the camera number on the keyboard and the image on the corresponding monitor.

2.Press #-ENTER(where # is the camera number without an address).

3.Press ON-999-ENTERto invoke an on-screen display of cameras on the system without an address.

F01U064036 1.0 2007.01

VG4-200, VG4-300, VG4-500i Series User’s Manual

Bosch Security Systems, Inc.

Image 8
Contents AutoDome Modular Camera System Page Symbols PrefaceAudience Document ConventionsCustomer Support and Service Related PublicationsTable of Contents Keyboard Commands by Number Advanced Features Configuring and Using the IP AutoDomePowering On Getting StartedEstablishing AutoDome Control Basic Keyboard OperationSetting the Camera Address Keyboard CommandsFastAddress To set an address to a camera without an addressSetting Passwords Special PasswordsPassword Security Level To set or change a password locked commandPage Setup Menu To open the main Setup Menu locked commandSetup Menu On-Screen Display Menu NavigationSetup Menu Choices Camera Setup Menu Camera Setup Menu ChoicesATW AutoOFF Lens Setup Lens Setup Menu ChoicesSpot ConstantNormal PTZ Setup MenuPTZ Menu Choices Page Display Setup Menu Display Setup Menu ChoicesMomentary OSDCommunication Setup Menu Communication Setup Menu ChoicesAlarm I/O Setup Alarm Setup Menu ChoicesInputs Setup InputsOutputs Setup Menu Outputs SetupAlarm Relay OutputsRule Setup Menu Rule Setup Menu ChoicesRule EmptyRule # Choices Menu Description Default Setting Exit Language MenuLanguage Menu Choices Choose a languageAdvanced Feature Setup Menu available with Series 500i only Advanced Feature Setup Menu ChoicesBist Diagnostics MenuDiagnostics Events Common AutoDome User Commands unlocked Setting AutoPan ModeSetting Preset Shots Configuring Preposition ToursProgramming the Inactivity Operation Recording ToursSwitch Location LEDs RS485 CPU Module Board Pelco Protocol ModeHardware Configuration Pelco Keyboard Commands Special Preset CommandsPreset Command Description Address GuidelinesPelco On-Screen Menus Main Setup MenuTo open the Pelco main Setup Menu locked commands Pelco menu Bosch menu Command Lock lockedBosch Menu locked Camera Setup unlocked OutdoorRecording Autopivot = Factory Setting Focus / Iris Select PTZ Setup unlockedPTZ Setup Menu Choices Menu Description Default Setting Edit Password locked Restore All Settings lockedOther Menus Not SetPage Keyboard Commands by Number Locked Function Comm Command Description Series Key901-964 Advanced Features Alarm RulesExample 1 Basic Alarm Rule Define the Alarm Outputs from the Outputs Setup menuExample 2 Advanced Alarm Rule Turn on AutoTrackAutoTrack Privacy MaskingVirtual Masking Motion Detection with Region of InterestTo set up a scene with Motion Detection Pre-position TourConfiguring and Using the IP AutoDome Overview of FeaturesConnecting the IP AutoDome to the PC System RequirementsConfiguring the IP Camera AutoDome IP System ConfigurationInstalling the Required Software Changing the Network SettingsTo install the software Using Configuration ManagerViewing Live Images and Controlling the AutoDome PTZ Establishing a ConnectionConfiguring Data Streams Controlling Camera OperationsView Control Tab Number DescriptionDigital I/O System and Event LogsEntering a Keyboard Control Command To Enter a Keyboard Control CommandAux Control Tab Number DescriptionOn this page? link to open the IP AutoDome online help To Set a Preset ShotTo View a Preset Shot Page Troubleshooting Guide If amber LED does not light when given PTZ commands, then Cannot access userSettings No camera controlPicture is dark Colors are not corRect If O.K., then Background is tooDoes not switch auto If O.K., then Matically when image Bubble is foggy If status reports Heater No Power, thenDay/Night camera Is dark Inside of EnviroDomeGlossary of Cctv Terms Biphase AutoScalingAutoTrack Auto White Balance AWBColor Temperature Ctfid Configuration Tool for Imaging DevicesDefault Shutter Day/Night IR sensitiveFast Address Fiber Optic TransmissionField of View Focal LengthImage Stabilization Infrared IlluminationIP Address IPS Images Per SecondMulti-Protocol Modal Dispersion or Intermodal DispersionMultimode Fiber Preset Tour Pressurized Dry Nitrogen HousingNema National Electrical Manufacturers Association Rating NightSenseResolution Region of InterestRS232/485 RuleTCP/IP Transmission Control Protocol/Internet Protocol TiltTri-streaming UTP Unshielded Twisted PairPage Index NumericsEn Index AutoDome Modular Camera System Jpeg En Index AutoDome Modular Camera System PTZ TCP/IP User Commands by Number Function Comm Command Description Series KeyPage Page Americas Europe, Middle East, Asia Asia-Pacific
Related manuals
Manual 139 pages 49.25 Kb

VG4-500I, VG4-200, VG4-300 specifications

Bosch Appliances is renowned for its commitment to quality and innovation, and their VG4 series of ventilation hoods is no exception. The VG4-300, VG4-200, and VG4-500I models are designed to cater to various kitchen needs, providing effective air filtration while maintaining aesthetic appeal.

The VG4-300 model is characterized by its sleek design and robust performance. It features a powerful motor that delivers efficient ventilation, removing smoke, odors, and grease from your kitchen swiftly. One of the standout features is its three-speed fan system, which allows users to select the appropriate level of airflow based on cooking intensity. Additionally, the grease filter is dishwasher-safe, ensuring easy maintenance and longevity.

In contrast, the VG4-200 model is perfect for those seeking a compact yet powerful solution. Designed for smaller kitchens, it doesn’t compromise on performance. This model also offers a three-speed fan, providing sufficient airflow for everyday cooking activities. The LED lighting integrated into the design enhances visibility on your cooktop while adding a modern touch to your kitchen. With a focus on energy efficiency, the VG4-200 operates quietly, allowing for a pleasant cooking experience without distraction.

The VG4-500I model is a standout in the series, designed for larger, more demanding kitchens. With increased airflow capacity, it can handle vigorous cooking styles with ease. It also boasts an advanced filtration system that captures more airborne particles, enhancing indoor air quality. The model features a touch control panel for ease of use, giving users the ability to adjust settings seamlessly. Like its counterparts, the VG4-500I includes LED lighting and dishwasher-safe filters, making maintenance straightforward.

All three models in the VG4 series exemplify Bosch's dedication to advanced technologies. Noise reduction features ensure that the ventilation system operates quietly, allowing conversations in the kitchen without disturbance. Furthermore, the stylish and modern finishes of each model enhance kitchen aesthetics, making them suitable for any decor.

In summary, Bosch Appliances’ VG4-300, VG4-200, and VG4-500I ventilation hoods offer a range of features tailored to meet different culinary needs. From effective air filtration and energy-efficient operation to user-friendly controls and elegant designs, these models are crafted to elevate the cooking experience while ensuring a fresh and clean kitchen environment.