Bosch Appliances VG4-300, VG4-200, VG4-500I Example 2 Advanced Alarm Rule, Turn on AutoTrack

Page 40

36 en Advanced Features

AutoDome Modular Camera System

 

 

Example 2: Advanced Alarm Rule

Scenario: A 500i Series AutoDome located at an airport is set to AutoPan Between Limits from the parking garage to the airport terminal. The gate entering the airport has an alarm contact connected to the AutoDome, and the perimeter fence in the area of the gate has an infrared (IR) motion detection sensor connected to the AutoDome.

When both the gate contact and motion detector alarms are activated at the same time, we want the alarm rule to:

1.Flash an OSD message (***ALARM 2***) on the monitor.

2.Stop the AutoPan and move the camera to a saved position (Shot 5) viewing the fence.

3.Turn on AutoTrack.

4.Transmit a Bilinx signal to the head end system to trigger an alarm response.

The sequence to program this alarm rule example is as follows:

1.Wire and set the alarm Input(s).

a.Wire the motion detector to Input 1. (This circuit is normally open.)

b.Wire the gate alarm contact to Input 5. (This circuit is normally closed.)

i

NOTICE! For instruction on wiring alarm and relay connections, see the AutoDome Modular

Camera System Installation Manual.

 

From the Inputs Setup menu:

c.Ensure Input 1 (the motion detector) is set to N.O. (This is the default setting for Input 1.)

d.Ensure Input 5 (the gate contact) is set to N.C.

2.Set the alarm Outputs from the Outputs Setup menu:

a.Set Output 5 to OSD.

b.Set Output 6 to Transmit.

c.Set Output 7 to Shot 5.

d.Set Output 8 to AutoTrack.

3.Set up the Alarm Rule (For this example use Rule 2.) Select the alarm Inputs:

a.From the Rule Setup menu select Rule 2.

b.Set the first input to Alarm Input 1. (The motion detector.)

c.Set the second input to Alarm Input 5. (The gate alarm contact.)

Select the alarm Outputs:

d.Set the first output to OSD.

e.Set the second output to Shot 5 viewing the fence.

f.Set the third output to AutoTrack and select Latched.

g.Set the fourth output to Transmit (a Bilinx signal to the headend).

Enable the alarm Rule:

h.Highlight Enabled and select YES.

F01U064036 1.0 2007.01

VG4-200, VG4-300, VG4-500i Series User’s Manual

Bosch Security Systems, Inc.

Image 40
Contents AutoDome Modular Camera System Page Symbols PrefaceAudience Document ConventionsCustomer Support and Service Related PublicationsTable of Contents Keyboard Commands by Number Advanced Features Configuring and Using the IP AutoDomePowering On Getting StartedEstablishing AutoDome Control Basic Keyboard OperationSetting the Camera Address Keyboard CommandsFastAddress To set an address to a camera without an addressSetting Passwords Special PasswordsPassword Security Level To set or change a password locked commandPage Setup Menu To open the main Setup Menu locked commandSetup Menu On-Screen Display Menu NavigationSetup Menu Choices Camera Setup Menu Camera Setup Menu ChoicesATW AutoOFF Lens Setup Lens Setup Menu ChoicesSpot ConstantPTZ Menu Choices PTZ Setup MenuNormal Page Display Setup Menu Display Setup Menu ChoicesMomentary OSDCommunication Setup Menu Communication Setup Menu ChoicesAlarm I/O Setup Alarm Setup Menu ChoicesInputs Setup InputsOutputs Setup Menu Outputs SetupAlarm Relay OutputsRule Setup Menu Rule Setup Menu ChoicesRule EmptyRule # Choices Menu Description Default Setting Exit Language MenuLanguage Menu Choices Choose a languageAdvanced Feature Setup Menu available with Series 500i only Advanced Feature Setup Menu ChoicesDiagnostics Events Diagnostics MenuBist Common AutoDome User Commands unlocked Setting AutoPan ModeSetting Preset Shots Configuring Preposition ToursProgramming the Inactivity Operation Recording ToursHardware Configuration Pelco Protocol ModeSwitch Location LEDs RS485 CPU Module Board Pelco Keyboard Commands Special Preset CommandsPreset Command Description Address GuidelinesTo open the Pelco main Setup Menu locked commands Main Setup MenuPelco On-Screen Menus Bosch Menu locked Command Lock lockedPelco menu Bosch menu Camera Setup unlocked OutdoorPTZ Setup Menu Choices PTZ Setup unlockedRecording Autopivot = Factory Setting Focus / Iris Select Menu Description Default Setting Edit Password locked Restore All Settings lockedOther Menus Not SetPage Keyboard Commands by Number Locked Function Comm Command Description Series Key901-964 Advanced Features Alarm RulesExample 1 Basic Alarm Rule Define the Alarm Outputs from the Outputs Setup menuExample 2 Advanced Alarm Rule Turn on AutoTrackAutoTrack Privacy MaskingVirtual Masking Motion Detection with Region of InterestTo set up a scene with Motion Detection Pre-position TourConfiguring and Using the IP AutoDome Overview of FeaturesConnecting the IP AutoDome to the PC System RequirementsConfiguring the IP Camera AutoDome IP System ConfigurationInstalling the Required Software Changing the Network SettingsTo install the software Using Configuration ManagerViewing Live Images and Controlling the AutoDome PTZ Establishing a ConnectionConfiguring Data Streams Controlling Camera OperationsView Control Tab Number DescriptionDigital I/O System and Event LogsEntering a Keyboard Control Command To Enter a Keyboard Control CommandAux Control Tab Number DescriptionTo View a Preset Shot To Set a Preset ShotOn this page? link to open the IP AutoDome online help Page Troubleshooting Guide If amber LED does not light when given PTZ commands, then Cannot access userSettings No camera controlPicture is dark Colors are not corRect If O.K., then Background is tooDoes not switch auto If O.K., then Matically when image Bubble is foggy If status reports Heater No Power, thenDay/Night camera Is dark Inside of EnviroDomeGlossary of Cctv Terms Biphase AutoScalingAutoTrack Auto White Balance AWBColor Temperature Ctfid Configuration Tool for Imaging DevicesDefault Shutter Day/Night IR sensitiveFast Address Fiber Optic TransmissionField of View Focal LengthImage Stabilization Infrared IlluminationIP Address IPS Images Per SecondMultimode Fiber Modal Dispersion or Intermodal DispersionMulti-Protocol Preset Tour Pressurized Dry Nitrogen HousingNema National Electrical Manufacturers Association Rating NightSenseResolution Region of InterestRS232/485 RuleTCP/IP Transmission Control Protocol/Internet Protocol TiltTri-streaming UTP Unshielded Twisted PairPage Index NumericsEn Index AutoDome Modular Camera System Jpeg En Index AutoDome Modular Camera System PTZ TCP/IP User Commands by Number Function Comm Command Description Series KeyPage Page Americas Europe, Middle East, Asia Asia-Pacific