Bosch Appliances VG4-500I, VG4-200, VG4-300 user manual Diagnostics Menu, Diagnostics Events, Bist

Page 26

22 en On-Screen Display Menu Navigation

AutoDome Modular Camera System

 

 

2.11Diagnostics Menu

The Diagnostics menu provides access to a list of diagnostic tools and events.

Diagnostics

Exit...

 

Alarm Status...

 

BIST...

 

Internal Temp:

Deg F / Deg C

High Temp Events:

Deg F / Deg C

Highest Temp

Deg F / Deg C

Low Temp Events:

Deg F / Deg C

Lowest Temp

Deg F / Deg C

Security Access:

0

CTFID Access:

0

Homing Events:

0

Homing Failed:

0

Restart Events:

0

Low Volt Events:

0

Power Up Events:

0

Video Loss Events:

0

Focus / Iris: Save and Exit

Diagnostics Events:

Menu

Description

Sub-menu / Description

 

 

 

Exit

Saves and exits the menu.

 

 

 

 

Alarm Status

Enters the Alarm Status menu and displays

Alarm Inputs 1 to 7, Alarm Outputs 1 to

 

the real time status of alarm inputs and out-

3, and Alarm Relay

 

puts.

 

 

 

 

BIST

Enters the Perform Built-in Self Tests menu.

YES to start the BIST test.

 

If confirmed, the BIST tests start and the

NO to exit the Perform Built in Self

 

results displayed.

Tests menu.

 

 

 

Internal Temp.

Displays the current dome temperature.

 

 

 

 

High Temp Events

Displays the number of times the high tem-

 

 

perature threshold is exceeded.

 

 

 

 

Highest Temp

Displays the highest temperature reached.

 

 

 

 

Low Temp Events

Displays the number of times the low tem-

 

 

perature threshold is exceeded.

 

 

 

 

Lowest Temp

Displays the lowest temperature reached.

 

 

 

 

Security Access

Displays the number of times the locked-

 

 

command menu is unlocked.

 

 

 

 

CTFID Access

Displays the number of times the Configura-

 

 

tion Tool is accessed.

 

 

 

 

Homing Events

Displays the number of times the AutoDome

 

 

was rebooted.

 

 

 

 

Homing Failed

Displays the number of times the AutoDome

 

 

failed to home properly.

 

 

 

 

Restart Events

Displays the number of restart events.

 

 

 

 

Low Volt Events

Displays the number of times the AutoDome

 

 

dropped below the acceptable voltage limit.

 

 

 

 

Power Up Events

Displays the number of power up events.

 

 

 

 

Video Loss Events

Displays the number of time that video was

 

 

lost.

 

 

 

 

F01U064036 1.1 2007.01

VG4-200, VG4-300, VG4-500i Series User’s Manual

Bosch Security Systems, Inc.

Image 26
Contents AutoDome Modular Camera System Page Audience SymbolsPreface Document ConventionsCustomer Support and Service Related PublicationsTable of Contents Keyboard Commands by Number Advanced Features Configuring and Using the IP AutoDomeEstablishing AutoDome Control Powering OnGetting Started Basic Keyboard OperationFastAddress Setting the Camera AddressKeyboard Commands To set an address to a camera without an addressPassword Security Level Setting PasswordsSpecial Passwords To set or change a password locked commandPage Setup Menu Setup MenuTo open the main Setup Menu locked command On-Screen Display Menu NavigationSetup Menu Choices ATW Camera Setup MenuCamera Setup Menu Choices AutoOFF Spot Lens SetupLens Setup Menu Choices ConstantNormal PTZ Setup MenuPTZ Menu Choices Page Momentary Display Setup MenuDisplay Setup Menu Choices OSDCommunication Setup Menu Communication Setup Menu ChoicesInputs Setup Alarm I/O SetupAlarm Setup Menu Choices InputsAlarm Relay Outputs Setup MenuOutputs Setup OutputsRule Rule Setup MenuRule Setup Menu Choices EmptyRule # Choices Language Menu Choices Menu Description Default Setting ExitLanguage Menu Choose a languageAdvanced Feature Setup Menu available with Series 500i only Advanced Feature Setup Menu ChoicesBist Diagnostics MenuDiagnostics Events Setting Preset Shots Common AutoDome User Commands unlockedSetting AutoPan Mode Configuring Preposition ToursProgramming the Inactivity Operation Recording ToursSwitch Location LEDs RS485 CPU Module Board Pelco Protocol ModeHardware Configuration Preset Command Description Pelco Keyboard CommandsSpecial Preset Commands Address GuidelinesPelco On-Screen Menus Main Setup MenuTo open the Pelco main Setup Menu locked commands Pelco menu Bosch menu Command Lock lockedBosch Menu locked Camera Setup unlocked OutdoorRecording Autopivot = Factory Setting Focus / Iris Select PTZ Setup unlockedPTZ Setup Menu Choices Other Menus Menu Description Default Setting Edit Password lockedRestore All Settings locked Not SetPage Keyboard Commands by Number Locked Function Comm Command Description Series Key901-964 Example 1 Basic Alarm Rule Advanced FeaturesAlarm Rules Define the Alarm Outputs from the Outputs Setup menuExample 2 Advanced Alarm Rule Turn on AutoTrackVirtual Masking AutoTrackPrivacy Masking Motion Detection with Region of InterestTo set up a scene with Motion Detection Pre-position TourConfiguring and Using the IP AutoDome Overview of FeaturesConnecting the IP AutoDome to the PC System RequirementsConfiguring the IP Camera AutoDome IP System ConfigurationTo install the software Installing the Required SoftwareChanging the Network Settings Using Configuration ManagerViewing Live Images and Controlling the AutoDome PTZ Establishing a ConnectionView Control Tab Configuring Data StreamsControlling Camera Operations Number DescriptionDigital I/O System and Event LogsAux Control Tab Entering a Keyboard Control CommandTo Enter a Keyboard Control Command Number DescriptionOn this page? link to open the IP AutoDome online help To Set a Preset ShotTo View a Preset Shot Page Troubleshooting Guide Settings If amber LED does not light when given PTZ commands, thenCannot access user No camera controlRect If O.K., then Picture is darkColors are not cor Background is tooDay/Night camera Does not switch auto If O.K., then Matically when imageBubble is foggy If status reports Heater No Power, then Is dark Inside of EnviroDomeGlossary of Cctv Terms AutoTrack BiphaseAutoScaling Auto White Balance AWBDefault Shutter Color TemperatureCtfid Configuration Tool for Imaging Devices Day/Night IR sensitiveField of View Fast AddressFiber Optic Transmission Focal LengthIP Address Image StabilizationInfrared Illumination IPS Images Per SecondMulti-Protocol Modal Dispersion or Intermodal DispersionMultimode Fiber Nema National Electrical Manufacturers Association Rating Preset TourPressurized Dry Nitrogen Housing NightSenseRS232/485 ResolutionRegion of Interest RuleTri-streaming TCP/IP Transmission Control Protocol/Internet ProtocolTilt UTP Unshielded Twisted PairPage Index NumericsEn Index AutoDome Modular Camera System Jpeg En Index AutoDome Modular Camera System PTZ TCP/IP User Commands by Number Function Comm Command Description Series KeyPage Page Americas Europe, Middle East, Asia Asia-Pacific
Related manuals
Manual 139 pages 49.25 Kb

VG4-500I, VG4-200, VG4-300 specifications

Bosch Appliances is renowned for its commitment to quality and innovation, and their VG4 series of ventilation hoods is no exception. The VG4-300, VG4-200, and VG4-500I models are designed to cater to various kitchen needs, providing effective air filtration while maintaining aesthetic appeal.

The VG4-300 model is characterized by its sleek design and robust performance. It features a powerful motor that delivers efficient ventilation, removing smoke, odors, and grease from your kitchen swiftly. One of the standout features is its three-speed fan system, which allows users to select the appropriate level of airflow based on cooking intensity. Additionally, the grease filter is dishwasher-safe, ensuring easy maintenance and longevity.

In contrast, the VG4-200 model is perfect for those seeking a compact yet powerful solution. Designed for smaller kitchens, it doesn’t compromise on performance. This model also offers a three-speed fan, providing sufficient airflow for everyday cooking activities. The LED lighting integrated into the design enhances visibility on your cooktop while adding a modern touch to your kitchen. With a focus on energy efficiency, the VG4-200 operates quietly, allowing for a pleasant cooking experience without distraction.

The VG4-500I model is a standout in the series, designed for larger, more demanding kitchens. With increased airflow capacity, it can handle vigorous cooking styles with ease. It also boasts an advanced filtration system that captures more airborne particles, enhancing indoor air quality. The model features a touch control panel for ease of use, giving users the ability to adjust settings seamlessly. Like its counterparts, the VG4-500I includes LED lighting and dishwasher-safe filters, making maintenance straightforward.

All three models in the VG4 series exemplify Bosch's dedication to advanced technologies. Noise reduction features ensure that the ventilation system operates quietly, allowing conversations in the kitchen without disturbance. Furthermore, the stylish and modern finishes of each model enhance kitchen aesthetics, making them suitable for any decor.

In summary, Bosch Appliances’ VG4-300, VG4-200, and VG4-500I ventilation hoods offer a range of features tailored to meet different culinary needs. From effective air filtration and energy-efficient operation to user-friendly controls and elegant designs, these models are crafted to elevate the cooking experience while ensuring a fresh and clean kitchen environment.