18 en
2.8 | Rule Setup Menu |
| The Rule Setup Menu shows the status of the rules and lets you add new rules or modify an |
| existing rule. The default setting is Empty. |
|
|
i | NOTICE! You can program a total of 12 rules. You must define the inputs and outputs before |
you program a rule. See Section 2.7: Alarm I/O Setup on page 16 for instructions on configuring | |
alarm inputs and outputs. | |
|
|
| Rule Setup... |
Exit... |
|
1. Rule 1 | Enabled |
2. Rule 2 | Disabled |
3. Rule 3 | Invalid |
4. Rule 4 | Empty |
5. Rule 5 | Empty |
6. Rule 6 | Empty |
7. Rule 7 | Empty |
8. Rule 8 | Empty |
9. Rule 9 | Empty |
10. Rule 10 | Empty |
11. Rule 11 | Empty |
12. Rule 12 | Empty |
Focus / Iris: Select
Rule 1
Exit...
EnabledYES
Input:
Alarm Input 1
NONE
NONE
NONE
Output:
OSD
Shot 2
Alarm Relay 2 sec
NONE
Right / Left: Select Period Time
Focus / Iris: Select Type
Rule Setup Menu Choices:
Menu | Description | Default Setting | |
|
|
|
|
Exit | Saves and exits the |
|
|
| menu. |
|
|
|
|
|
|
Rule | Displays the status of a | Enabled: The rule inputs and outputs are properly | Empty |
| rule on the right side of | defined and the rule is turned on. |
|
| the menu. There are four | Disabled: The rule inputs and outputs are defined |
|
| (4) possible rule sta- | but the rule is turned off. |
|
| tuses. | Invalid: The rule has a missing or invalid input or out- |
|
|
| put. |
|
|
| Empty: The rule has no inputs or outputs defined. |
|
|
|
|
|
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows you to configure a rule from previously defined alarm inputs and outputs. Once an alarm is configured with valid inputs and outputs, it can be turned on or off (enabled or disabled) through its configuration menu.
F01U064036 1.1 2007.01 | Bosch Security Systems, Inc. |