Table of Contents

1

Getting Started

3

1.1

Powering On

3

1.2

Establishing AutoDome Control

3

1.2.1

Basic Keyboard Operation

3

1.2.2

Keyboard Commands

4

1.3

Setting the Camera Address

4

1.3.1

FastAddress

4

1.4

Setting Passwords

5

1.4.1

Special Passwords

5

2

On-Screen Display Menu Navigation

7

2.1

Setup Menu

7

2.2

Camera Setup Menu

9

2.3

Lens Setup

11

2.4

PTZ Setup Menu

12

2.5

Display Setup Menu

14

2.6

Communication Setup Menu

15

2.7

Alarm I/O Setup

16

2.8

Rule Setup Menu

18

2.9

Language Menu

20

2.10

Advanced Feature Setup Menu (available with Series 500i only)

21

2.11

Diagnostics Menu

22

3

Common AutoDome User Commands (unlocked)

23

3.1

Setting AutoPan Mode

23

3.2

Setting Preset Shots

23

3.3

Configuring Preposition Tours

23

3.4

Programming the Inactivity Operation

24

3.5

Recording Tours

24

4

Pelco® Protocol Mode

25

4.1

Hardware Configuration

25

4.2

Address Guidelines

26

4.3

Pelco Keyboard Commands

26

4.3.1

Special Preset Commands

26

5

Pelco On-Screen Menus

27

5.1

Setup Menu

27

5.1.1

Command Lock (locked)

28

5.1.2

Bosch Menu (locked)

28

5.1.3

PTZ Setup (unlocked)

30

5.1.4

Other Menus

31

Bosch Security Systems, Inc.

VG4-200, VG4-300, VG4-500i Series User’s Manual

F01U064036 1.0 2007.01

Image 5
Contents AutoDome Modular Camera System Page Preface SymbolsAudience Document ConventionsRelated Publications Customer Support and ServiceTable of Contents Configuring and Using the IP AutoDome Keyboard Commands by Number Advanced FeaturesGetting Started Powering OnEstablishing AutoDome Control Basic Keyboard OperationKeyboard Commands Setting the Camera AddressFastAddress To set an address to a camera without an addressSpecial Passwords Setting PasswordsPassword Security Level To set or change a password locked commandPage To open the main Setup Menu locked command Setup MenuSetup Menu On-Screen Display Menu NavigationSetup Menu Choices Camera Setup Menu Choices Camera Setup MenuATW AutoOFF Lens Setup Menu Choices Lens SetupSpot ConstantNormal PTZ Setup MenuPTZ Menu Choices Page Display Setup Menu Choices Display Setup MenuMomentary OSDCommunication Setup Menu Choices Communication Setup MenuAlarm Setup Menu Choices Alarm I/O SetupInputs Setup InputsOutputs Setup Outputs Setup MenuAlarm Relay OutputsRule Setup Menu Choices Rule Setup MenuRule EmptyRule # Choices Language Menu Menu Description Default Setting ExitLanguage Menu Choices Choose a languageAdvanced Feature Setup Menu Choices Advanced Feature Setup Menu available with Series 500i onlyBist Diagnostics MenuDiagnostics Events Setting AutoPan Mode Common AutoDome User Commands unlockedSetting Preset Shots Configuring Preposition ToursRecording Tours Programming the Inactivity OperationSwitch Location LEDs RS485 CPU Module Board Pelco Protocol ModeHardware Configuration Special Preset Commands Pelco Keyboard CommandsPreset Command Description Address GuidelinesPelco On-Screen Menus Main Setup MenuTo open the Pelco main Setup Menu locked commands Pelco menu Bosch menu Command Lock lockedBosch Menu locked Outdoor Camera Setup unlockedRecording Autopivot = Factory Setting Focus / Iris Select PTZ Setup unlockedPTZ Setup Menu Choices Restore All Settings locked Menu Description Default Setting Edit Password lockedOther Menus Not SetPage Locked Function Comm Command Description Series Key Keyboard Commands by Number901-964 Alarm Rules Advanced FeaturesExample 1 Basic Alarm Rule Define the Alarm Outputs from the Outputs Setup menuTurn on AutoTrack Example 2 Advanced Alarm RulePrivacy Masking AutoTrackVirtual Masking Motion Detection with Region of InterestPre-position Tour To set up a scene with Motion DetectionOverview of Features Configuring and Using the IP AutoDomeSystem Requirements Connecting the IP AutoDome to the PCAutoDome IP System Configuration Configuring the IP CameraChanging the Network Settings Installing the Required SoftwareTo install the software Using Configuration ManagerEstablishing a Connection Viewing Live Images and Controlling the AutoDome PTZControlling Camera Operations Configuring Data StreamsView Control Tab Number DescriptionSystem and Event Logs Digital I/OTo Enter a Keyboard Control Command Entering a Keyboard Control CommandAux Control Tab Number DescriptionOn this page? link to open the IP AutoDome online help To Set a Preset ShotTo View a Preset Shot Page Troubleshooting Guide Cannot access user If amber LED does not light when given PTZ commands, thenSettings No camera controlColors are not cor Picture is darkRect If O.K., then Background is tooBubble is foggy If status reports Heater No Power, then Does not switch auto If O.K., then Matically when imageDay/Night camera Is dark Inside of EnviroDomeGlossary of Cctv Terms AutoScaling BiphaseAutoTrack Auto White Balance AWBCtfid Configuration Tool for Imaging Devices Color TemperatureDefault Shutter Day/Night IR sensitiveFiber Optic Transmission Fast AddressField of View Focal LengthInfrared Illumination Image StabilizationIP Address IPS Images Per SecondMulti-Protocol Modal Dispersion or Intermodal DispersionMultimode Fiber Pressurized Dry Nitrogen Housing Preset TourNema National Electrical Manufacturers Association Rating NightSenseRegion of Interest ResolutionRS232/485 RuleTilt TCP/IP Transmission Control Protocol/Internet ProtocolTri-streaming UTP Unshielded Twisted PairPage Numerics IndexEn Index AutoDome Modular Camera System Jpeg En Index AutoDome Modular Camera System PTZ TCP/IP Function Comm Command Description Series Key User Commands by NumberPage Page Asia-Pacific Americas Europe, Middle East, Asia