Bosch Appliances VG4-500I, VG4-200, VG4-300 user manual AutoTrack, Privacy Masking, Virtual Masking

Page 41

AutoDome Modular Camera System

Advanced Features en 37

 

 

7.2 AutoTrack

The 500i Series AutoDome features enhanced AutoTrack software with more versatility and smoother object tracking. AutoTrack is now able to continuously follow an object even if it passes behind a Privacy Mask. When used with Virtual Mask, it is able to ignore predefined areas of background motion.

To turn on AutoTrack, enter the keyboard command ON-78-ENTER.

In Pelco Mode, open the Main menu, select the Advanced menu, and then select AutoTrack On.

NOTICE! For proper operation AutoTrack requires that the camera height be set in the

i software. Open the Bosch Main menu, select the Advanced menu and select Camera Height to enter the camera height.

7.3

 

Privacy Masking

 

 

Available with 300 and 500i Series AutoDomes, Privacy Masking is used to block out a specific

 

 

area of a scene from being viewed. Mask choices have been expanded to include black, white,

 

 

or blurred, and can be configured with three, four, or five corners to cover more complex

 

 

shapes.

 

 

 

 

i

NOTICE! Privacy Masking does not hinder AutoTrack from tracking an object.

 

 

 

 

 

 

 

Privacy Masking can be accessed through the Main menu, by selecting Display Setup, and

 

 

then Privacy Mask, or entering the keyboard command ON-87-ENTER. To setup a privacy

 

 

mask, follow the on-screen menu instructions.

 

 

– In Pelco Mode, Privacy Masking can be accessed through the Pelco Main menu, by select-

 

 

ing the Bosch Menu, then selecting the Display Setup menu, and finally selecting Privacy

 

 

Masking. To setup a privacy mask, follow the on-screen menu instructions

7.4

 

Virtual Masking

Only available with the 500i Series AutoDome, Virtual Masking is a unique Bosch technology that allows you to create an "invisible" area that ignores unwanted background motion. These invisible masks are similar to privacy zones, except that the AutoDome AutoTrack and Motion Detection algorithms can see them.

Virtual Masking can be accessed by opening the Main menu, selecting the Advanced menu, then selecting Virtual Masking. To setup a Virtual Mask follow the on-screen menu instructions.

In Pelco Mode, open the Main menu, select the Advanced menu, then select Virtual Mask- ing. To setup a Virtual Mask follow the on-screen menu instructions.

7.5 Motion Detection with Region of Interest

With the 500i Series AutoDome, the motion detection software can be configured to create a Region of Interest within multiple preset positions or scenes. It can take advantage of Virtual Masking to ignore motion in predefined areas. Motion Detection can also be used as an Alarm Rule input.

Preset positions 90 through 99 are reserved for programming motion detection scenes.

Bosch Security Systems, Inc.

VG4-200, VG4-300, VG4-500i Series User’s Manual

F01U064036 1.0 2007.01

Image 41
Contents AutoDome Modular Camera System Page Preface SymbolsAudience Document ConventionsRelated Publications Customer Support and ServiceTable of Contents Configuring and Using the IP AutoDome Keyboard Commands by Number Advanced FeaturesGetting Started Powering OnEstablishing AutoDome Control Basic Keyboard OperationKeyboard Commands Setting the Camera AddressFastAddress To set an address to a camera without an addressSpecial Passwords Setting PasswordsPassword Security Level To set or change a password locked commandPage To open the main Setup Menu locked command Setup MenuSetup Menu On-Screen Display Menu NavigationSetup Menu Choices Camera Setup Menu Choices Camera Setup MenuATW AutoOFF Lens Setup Menu Choices Lens SetupSpot ConstantNormal PTZ Setup MenuPTZ Menu Choices Page Display Setup Menu Choices Display Setup MenuMomentary OSDCommunication Setup Menu Choices Communication Setup MenuAlarm Setup Menu Choices Alarm I/O SetupInputs Setup InputsOutputs Setup Outputs Setup MenuAlarm Relay OutputsRule Setup Menu Choices Rule Setup MenuRule EmptyRule # Choices Language Menu Menu Description Default Setting ExitLanguage Menu Choices Choose a languageAdvanced Feature Setup Menu Choices Advanced Feature Setup Menu available with Series 500i onlyBist Diagnostics MenuDiagnostics Events Setting AutoPan Mode Common AutoDome User Commands unlockedSetting Preset Shots Configuring Preposition ToursRecording Tours Programming the Inactivity OperationSwitch Location LEDs RS485 CPU Module Board Pelco Protocol ModeHardware Configuration Special Preset Commands Pelco Keyboard CommandsPreset Command Description Address GuidelinesPelco On-Screen Menus Main Setup MenuTo open the Pelco main Setup Menu locked commands Pelco menu Bosch menu Command Lock lockedBosch Menu locked Outdoor Camera Setup unlockedRecording Autopivot = Factory Setting Focus / Iris Select PTZ Setup unlockedPTZ Setup Menu Choices Restore All Settings locked Menu Description Default Setting Edit Password lockedOther Menus Not SetPage Locked Function Comm Command Description Series Key Keyboard Commands by Number 901-964 Alarm Rules Advanced FeaturesExample 1 Basic Alarm Rule Define the Alarm Outputs from the Outputs Setup menuTurn on AutoTrack Example 2 Advanced Alarm RulePrivacy Masking AutoTrackVirtual Masking Motion Detection with Region of InterestPre-position Tour To set up a scene with Motion DetectionOverview of Features Configuring and Using the IP AutoDomeSystem Requirements Connecting the IP AutoDome to the PCAutoDome IP System Configuration Configuring the IP CameraChanging the Network Settings Installing the Required SoftwareTo install the software Using Configuration ManagerEstablishing a Connection Viewing Live Images and Controlling the AutoDome PTZControlling Camera Operations Configuring Data StreamsView Control Tab Number DescriptionSystem and Event Logs Digital I/OTo Enter a Keyboard Control Command Entering a Keyboard Control CommandAux Control Tab Number DescriptionOn this page? link to open the IP AutoDome online help To Set a Preset ShotTo View a Preset Shot Page Troubleshooting Guide Cannot access user If amber LED does not light when given PTZ commands, thenSettings No camera controlColors are not cor Picture is darkRect If O.K., then Background is tooBubble is foggy If status reports Heater No Power, then Does not switch auto If O.K., then Matically when imageDay/Night camera Is dark Inside of EnviroDomeGlossary of Cctv Terms AutoScaling BiphaseAutoTrack Auto White Balance AWBCtfid Configuration Tool for Imaging Devices Color TemperatureDefault Shutter Day/Night IR sensitiveFiber Optic Transmission Fast AddressField of View Focal LengthInfrared Illumination Image StabilizationIP Address IPS Images Per SecondMulti-Protocol Modal Dispersion or Intermodal DispersionMultimode Fiber Pressurized Dry Nitrogen Housing Preset TourNema National Electrical Manufacturers Association Rating NightSenseRegion of Interest ResolutionRS232/485 RuleTilt TCP/IP Transmission Control Protocol/Internet ProtocolTri-streaming UTP Unshielded Twisted PairPage Numerics IndexEn Index AutoDome Modular Camera System Jpeg En Index AutoDome Modular Camera System PTZ TCP/IP Function Comm Command Description Series Key User Commands by NumberPage Page Asia-Pacific Americas Europe, Middle East, Asia