Pick-up Device:

768 (H) x 494 (V) pixels, Interline Transfer CCD

Scanning Area:

4.9 (H) x 3.7 (V) mm (Equivalent to scanning area of 1/3” pick-up tube)

Synchronization:

Internal, External, Line-locked or Multiplexed vertical drive (VD2) selectable

Scanning System:

2 : 1 interlace

 

Scanning:

525 lines / 60 fields / 30 frames

Horizontal:

15.734 kHz

 

Vertical:

59.94 Hz

 

Horizontal Resolution:

570 lines

 

Video Output:

1.0 V[p-p] EIA composite 75 / BNC connector

Signal-to-Noise Ratio:

50 dB (AGC OFF)

 

Electronic Light Control:

Equivalent to continuous variable shutter speed between 1/60 s

 

and 1/10 000 s

 

Minimum Illumination:

0.08 lx (0.008 footcandle) at F1.4, AGC ON

Gain Control:

AGC ON (+18 dB) or OFF selectable

Lens Mount:

C-mount or CS-mount selectable

Ambient Operating Temperature:

10°C - +50°C (14°F - 122°F)

Ambient Operating Humidity:

Less than 90%

 

Power Source and

WV-BP330:

120V AC, 60 Hz, 3.5W

Power Consumption:

WV-BP332:

12V DC, 250 mA

 

WV-BP334:

24V AC, 60 Hz, 3.5W

-16-

Image 18
Contents WV-BP330/WV-BP332/WV-BP334 This equipment generates and uses radio frequency energy Contents Features PrefaceDo not attempt to disassemble the camera PrecautionsClean the CCD faceplate with care Handle the camera with careMajor Operating Controls and Their Functions WV-BP330Power Cord only WV-BP330 Auto Iris lens ConnectorFlange-back Adjusting Ring Lens option Camera Mounting Screw Hole4Vertical Phase Control Phase only WV-BP330 and WV-BP334 1Back Light Compensation Mode Selector BLC2Lens Drive Signal Selector VIDEO, DC 6Video Output Connector Video OUT7Gen-lock Input Connector GEN-LOCK Connections WV-BP330 120V AC 60HzWV-BP332 12V DC Recommended wire gauge sizes for 24V AC line WV-BP334 24V AC 60HzType RG-59/U RG-6/U RG-11/U RG-15/U Coaxial cable Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Installation of Camera Mounting from the bottomMounting from the top Prevention of Blooming and Smear Specifications Standard Accessories Version Française Table DES Matières Prèface Caractéristiques DominantesMesures DE Précaution Manipuler la caméra vidéo de surveillance délicatementPage Principaux Organes DE Commande ET Leurs Fonctions Connecteur de cordon d’objectif à diaphragme automatique Bague de réglage de foyer arrière2Sélecteur de signal de commande d’objectif VIDEO, DC 6Connecteur de sortie vidéo Video OUT Mesures de précautionBranchement DE Système WV-BP330 Courant alternatif 120 V, 60 HzWV-BP332 courant continu 12 Câble vidéo WV-BP334 courant alternati 24 V,60HzType de RG-59/U RG-6/U RG-11/U RG-15/U Câble coaxial Installation de l’objectif Page Réglage DE Mise AU Point OU DE Foyer Arrière Installation DE LA Caméra Vidéo DE Surveillance Fixation par la baseFixation par le haut Mesure Préventive Contre L’HYPERLUMINOSITÉ ET LE Traînage Caractéristiques Techniques Accessoires Standard Capuchon d’objectif Connecteur d’objectif ALC YFE4191J100Page V8QA4916EN Imprimé en Chine