Panasonic GP-US532HA, GP-US522HA operating instructions Connections, Internal Sync Operation

Page 9

CONNECTIONS

Cautions :

1.Keep the DC POWER ON/OFF switch in the OFF posi- tion until all connections have been properly made.

2.Connect the camera head and camera control unit.

Internal Sync Operation

1.Connect the camera cable between the camera head and the camera control unit.

2.Connect the coaxial cable with BNC connectors between the video output connector of the camera control unit and the video monitor or VCR.

 

Video

VCR or

 

Monitor

Video Monitor

 

75

VIDEO

75

VIDEO

 

Hi-Z

Hi-Z

Coaxial

IN

OUT

IN

OUT

Cable

 

 

 

 

CCU

VBS/HD

VD

75

S-VIDEO

DC 12V IN

ON

OUT

RS-232C

 

 

OFF

 

1 VIDEO 2

 

 

 

 

RGB/SYNC

3.Connect the power cable between the DC 12 V input terminals and the 12 V DC power supply unit (obtained locally).

The maximum cable length between camera control unit and power supply unit is calculated as follows:

11.5V DC < VA - (R x 0.42 x L) < 16 V DC

L : Cable length (meter)

R : Resistance of copper wire (/meter)

VA : DC output voltage of power supply unit

L standard = VA - 12 / 0.42 x R (meter)

L minimum = VA - 16 / 0.42 x R (meter)

L maximum = VA - 11.5 / 0.42 x R (meter)

Cautions :

1.Connect to 12 V DC (11.5 V - 16 V) class 2 power supply only.

2.To prevent fire or electric shock hazard, use a UL listed wire VW-1, Style 1007 cable for 12 V DC input terminals.

Gen-lock Operation

1.Connect the camera cable between the camera head and the camera control unit.

2.Connect the coaxial cable with BNC connectors between the video output connector of the camera control unit and the video input connector of Special Effects Generator (SEG), and between the VBS/HD input connector of the camera control unit.

CCU

VBS/HD

VD

75

S-VIDEO

DC 12V IN

ON

OUT

RS-232C

 

 

OFF

 

1 VIDEO 2

 

 

 

 

RGB/SYNC

 

VBS/HD In

 

VIDEO Out

 

 

 

 

 

 

 

75set to ON

 

 

 

 

CCU

VBS/HD

VD

75

S-VIDEO

DC 12V IN

ON

OUT

RS-232C

 

 

OFF

 

1 VIDEO 2

 

 

 

 

RGB/SYNC

 

VBS/HD In

VIDEO Out

 

 

 

 

75set to ON

Black Burst VIDEO In

Out

Special Effects Generator

(SEG)

3.Connect the power cable between the DC 12 V input terminals and the 12V DC power supply unit (obtained locally).

Cautions :

1.Connect to 12 V DC (11.5 V - 16 V) class 2 power supply only.

2.To prevent fire or electric shock hazard, use a UL listed wire VW-1, Style 1007 cable for 12 V DC input terminals.

9

Image 9
Contents GP-US532HA Contents Preface FeaturesClean the faceplate with care PrecautionsPut the lens cap on the camera after using the camera Ask a qualified service person for installationPower Indicator Power Camera Cable ConnectorLens Mount Camera Mounting Screw HoleTitle Input Connector Title Auto Warning IndicatorCamera/Color Bar Selector CAM/BAR White Balance Selector ATW/AWC/MANUGen-lock Signal Input Connector VBS/HD Camera Cable Connector CameraExternal HD and VD Mode Gen-Lock Signal Input Connector VDRGB/SYNC Output Connector RGB/SYNC Video Output Connector S-VIDEO OUTRS-232C Connector RS-232C DC Input Terminals 12V DCInternal Sync Operation ConnectionsLens Mount Mounting the LensItem Button Item SetupThis button is used to move the cursor downwards Left Button aEditing the Setup menu Opening the Setup menuAll Reset Operation Press the page button for a few secondsSetting Procedures Field/Frame Charging Mode Setting FLD/FRMCamera Identification Camera ID ELC detection control area setting ELC Electronic Light Control Setting ELCPeak and Average Weight Control PEAK/AVE Manual setting of the ELC detection control area ManuElectronic Shutter Speed Setting Shutter Gain Control Setting GainAGC detection control area setting AGC Internal Sync Mode INT Synchronization Setting SyncVBS Gen-lock Mode Extvbs Maximum +9 dBSubcarrier Coarse Phase Adjustment SC Coarse Horizontal Phase Adjustment H PhaseSubcarrier Fine Phase Adjustment SC Fine VS Gen-lock Mode ExtvsExternal HD/VD Mode HD/VD Black Balance Setting Black BALExternal VD Mode VD Auto Black Balance Setting Black BALScene File Setting Scene File Returning to the Setup menuTo turn Chroma Phase Control HUE Clear Digital Noise Reduction Control Clean DNRTo reset to the factory setting Gamma Correction GammaPrevention of Blooming and Smear Specifications GP-CA522/4 Optional AccessoriesCharacter Generators Division of Matsushita Electric Corporation of America