Panasonic GP-US532HA Lens Mount, Camera Cable Connector, Camera Mounting Screw Hole, Front Panel

Page 5

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

Camera Head

1.Lens Mount

This is used to attach the special C-mount lens for GP- US522 and the C-mount lens for GP-US532.

2.

Camera Cable Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This 24-pin connector is used to connect the optional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

camera cable GP-CA522/4 to the camera control unit.

 

 

 

 

 

 

 

 

 

3.

Camera Mounting Screw Hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This hole (1/4" - 20) is used to mount the camera onto

q

 

 

 

 

 

 

 

 

a mounting bracket.

e

 

 

 

w

Camera Control Unit

[Front Panel]

DC POWER ON

OFF

GAIN

 

PAGE ITEM

 

 

 

HIGH

ATW

 

 

 

 

 

LEVEL

TITLE

CAMERA

LOW

AWC

 

 

OFF

MANU

 

(AWC) (ABC)

 

 

 

CAM

R

B

1

ON

 

 

 

 

 

 

BAR

 

 

2

OFF

 

 

 

 

 

SCENE

ELC

 

 

 

 

GAIN

 

Camera Control Unit GP-US522

 

 

 

 

 

 

4.

Power ON/OFF Switch (DC POWER ON/OFF)

6. Automatic/Manual Gain Selector Switch

 

This switch turns the power of this unit and the power

 

(GAIN HIGH/LOW/OFF)

 

 

supply for the camera head on or off.

 

This selector is used to select the gain of video amplifi-

 

 

 

er as follows.

 

 

5.

Power Indicator (POWER)

 

The mode can be selected in the SET UP menu.

 

This indicator lights up red when the power switch is

 

Refer to page 16.

 

 

turned on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE

 

POSITION OF SW

GAIN

 

 

 

 

 

HIGH

Maximum +18 dB

 

 

 

AUTO

 

LOW

Maximum + 9 dB

 

 

 

 

 

OFF

0 dB

 

 

 

 

 

HIGH

+18 dB (Fixed)

 

 

 

MANU

 

LOW

+9 dB (Fixed)

 

 

 

 

 

OFF

0 dB

5

Image 5
Contents GP-US532HA Contents Preface FeaturesClean the faceplate with care PrecautionsPut the lens cap on the camera after using the camera Ask a qualified service person for installationPower Indicator Power Camera Cable ConnectorLens Mount Camera Mounting Screw HoleTitle Input Connector Title Auto Warning IndicatorCamera/Color Bar Selector CAM/BAR White Balance Selector ATW/AWC/MANUGen-lock Signal Input Connector VBS/HD Camera Cable Connector CameraExternal HD and VD Mode Gen-Lock Signal Input Connector VDRGB/SYNC Output Connector RGB/SYNC Video Output Connector S-VIDEO OUTRS-232C Connector RS-232C DC Input Terminals 12V DCInternal Sync Operation ConnectionsLens Mount Mounting the LensItem Button Item SetupThis button is used to move the cursor downwards Left Button aEditing the Setup menu Opening the Setup menuAll Reset Operation Press the page button for a few secondsCamera Identification Camera ID Setting ProceduresField/Frame Charging Mode Setting FLD/FRM ELC detection control area setting ELC Electronic Light Control Setting ELCPeak and Average Weight Control PEAK/AVE Manual setting of the ELC detection control area ManuAGC detection control area setting AGC Electronic Shutter Speed Setting ShutterGain Control Setting Gain Internal Sync Mode INT Synchronization Setting SyncVBS Gen-lock Mode Extvbs Maximum +9 dBSubcarrier Coarse Phase Adjustment SC Coarse Horizontal Phase Adjustment H PhaseSubcarrier Fine Phase Adjustment SC Fine VS Gen-lock Mode ExtvsExternal HD/VD Mode HD/VD Black Balance Setting Black BALExternal VD Mode VD Auto Black Balance Setting Black BALTo turn Scene File Setting Scene FileReturning to the Setup menu Chroma Phase Control HUE Clear Digital Noise Reduction Control Clean DNRTo reset to the factory setting Gamma Correction GammaPrevention of Blooming and Smear Specifications GP-CA522/4 Optional AccessoriesCharacter Generators Division of Matsushita Electric Corporation of America