Kenwood TM-V71A, TM-V71E instruction manual Selecting a Scan Resume Method, VFO Scan

Page 51

SELECTING a SCAN RESUME METHOD

The transceiver stops scanning at a frequency or Memory channel on which a signal is detected. It then continues scanning according to which resume mode you have selected. You can choose one of the following modes. The default is Time-operated mode.

Time-Operated mode

The transceiver remains on a busy frequency or Memory channel for approximately 5 seconds, and then continues to scan even if the signal is still present.

Carrier-Operated mode

The transceiver remains on a busy frequency or Memory channel until the signal drops out. There is a 2 second delay between signal drop-out and scan resumption.

Seek mode

The transceiver remains on a busy frequency or Memory channel even after the signal drops out and does not automatically resume scanning.

Note: To temporarily stop scanning and monitor weak signals, press the microphone PF key assigned to the Monitor function {page 66}. Press the PF key again to resume scanning.

1Enter Menu mode and access Menu 514 (SC.RESM) {page 20}.

2Set the Scan Resume mode to TO (Time-Operated), CO (Carrier-Operated) or SEEK.

VFO SCAN

VFO Scan monitors all frequencies tunable on the band, using the current frequency step size.

1Select your desired band.

2Press [VFO] (1s).

Scan starts at the current frequency.

The 1 MHz decimal blinks while scanning is in progress.

To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].

3To quit VFO Scan, press [VFO] again.

43

Image 51
Contents 144/430 MHz FM Dual Bander 144/440 MHz FM Dual BanderWriting Conventions Followed in this Manual FeaturesThis transceiver has the following main features Thank YouOne or more of the following statements may be applicable When Condensation Occurs Inside the TransceiverPrecautions Contents Using Ctcss Ctcss Frequency ID Using DCS DCS Code IDManual Dialing Automatic dialer VGS-1 Optional Voice Guide & Storage Unit Dtmf Key LockOptions Part Number Quantity Supplied AccessoriesMobile Installation PreparationMobile Operation Power Cable ConnectionFixed Station Operation Fuse Location Fuse Current Rating Located on the DC connectorSupplied DC power cable Replacing FusesAntenna Connection Front Panel Orientation Accessory Connections External SpeakersMicrophone Front Panel Getting Acquainted0PF2 REVLOW PF1Display Indicator DescriptionAppears while accessing the Menu Sub-Panel Rear PanelMicrophone MC-59 Press the switch again to switch the transceiver OFF Switching the Power ON/ OFFAdjusting the Volume Press the switch to switch the transceiver onAdjusting the Squelch Selecting a BandBand a left Band SEL control Band B right Band SEL control Selecting Dual band mode/ single band Mode Frequency ranges Selecting a frequency bandSelecting an Operating mode VFO ModeMemory Channel Mode Transmitting Call Channel ModePress Call to enter Call Channel mode When you finish speaking, release the PTT switchPress F, Tuning control to access the Menu Menu ModeMenu Access Menu ConfigurationANN.SPD DT.SPD MIC.LCK Repeat steps 2 and 3 to enter the remaining characters Rotate the Tuning control to select your desired characterPress the Tuning control to set the selected character Character EntryKey Character Display with each press of the key Microphone Keypad Character EntryRepeater Access Operating Through RepeatersSelecting an Offset Direction Activating the Tone Function Selecting an Offset FrequencyFrequency Rotate the Tuning control to select your desired frequencySelecting a Tone Frequency Press F, ToneAutomatic Repeater Offset K and E Types Only Transmitting a 1750 Hz Tone Reverse FunctionAutomatic Simplex Checker ASC Press F, Tone 1s to run the Tone Frequency ID scan Tone Frequency IDMemory Channels Simplex & Repeater or ODD-SPLIT Memory CHANNEL?Parameter Simplex Odd-split Storing Simplex and Standard Repeater Frequencies Storing Odd-Split Repeater FrequenciesCall Channel Memory Simplex Recalling a Memory Channel Call Channel Memory Odd-SplitMemory Recall Method Clearing a Memory Channel Turn the transceiver power OFFPress MR + Power on Press the Tuning control to clear the Memory channelPress F, VFO Switching the Memory Name/ Frequency DisplayMemory-TO-VFO TRansfer Channel Display FUnctionKEY KEY 1s While KEY + Key NameProgrammable Memory PM Application Examples Storing Data in PM Channels Recalling PM ChannelsPress F, PM Auto PM Channel store PM Channel ResetPress F + Power on Press the Tuning control again to reset the PM channelsScan Type Scan Range ScanVFO Scan Selecting a Scan Resume MethodTo quit Memory Scan, press MR again Memory ScanLocking Out a Memory Channel Press MR 1sMemory Group Channel Range To quit Group Scan, press the Tuning control againGroup Scan Memory Group LinkSetting Scan Limits Program ScanPress VFO To quit Program Scan, press VFO again Using Program ScanTo quit Call Scan, press Call again To quit MHz Scan, press the Tuning control againMHz Scan Call ScanContinuous Tone Coded Squelch System Ctcss Using CtcssPress Enter again to complete the setting Press F, Tone 1s Ctcss FREQuency IDUsing DCS Rotate the Tuning control to select your desired DCS codeDigital Coded Squelch DCS DCS Code DCS Code ID 1209 1336 1447 1633 697 770 852 941 Dual Tone MULTI-FREQUENCY DtmfManual Dialing Dtmf HoldStoring a Dtmf Code in Memory Automatic DialerSelecting a Transmit Speed Transmitting Stored Dtmf CodesSelecting a Pause Duration Dtmf Key LockStoring EchoLink memory What is EchoLink?Transmitting EchoLink Memory TxD RxD Setting Up EchoLink Sysop ModeEchoLink Sysop Mode on TM-V71 EchoLink Sysop Mode OFF TM-V71Auto Display Brightness POWER-ON MessageAuxiliary Functions Display BrightnessTo turn Key Lock on or OFF, press F 1s Key LockBacklight Color Microphone Key LockBeep Volume Key BeepProgrammable VFO Changing the Frequency Step Size Programmable Function Keys Transceiver Front PanelMicrophone Keys Frequency Direct Entry Automatic Power OFF APOMeter Squelch Advanced Intercept Point AIPSquelch Hang Time Switching FM/AM Mode Beat ShiftSpeaker Mute Selecting an Output Power TIME-OUT Timer TOTMute Hang Time Speaker Band Output External Speaker ConfigurationSetup Masking a BandDisplay Partition Bar Memory Name Location Weather Alert K Type Models OnlyWeather Channel Channel NoEnter your password Power On PasswordCurrent frequency/code VGS-1 Optional Voice Guide & Storage UnitVoice Announcements Operation AnnouncementAuto Voice Announcement Volume Voice Announcement LanguageVoice Announcement Speed Voice Memos Voice RecorderConversation Recorder Playback Playback RepeatPlayback Repeat Interval CROSS-BAND/ LOCKED-BAND Operation K Type Models only Press Tone + Power onRepeater Hold Repeater IDEntering your Repeater ID Data Terminal Speed Data terminal pinsPacket Operation Data BandPC Port Speed SQC Output SettingPreparation Wireless Operation K Type Models onlyControl Operation Operation Dtmf CommandTransceiver Reset Menu Mode Memory control program MCP-2A Using the MCP-2A SoftwareUsing the MCP-2A software, you can OptionsPC terminal pins Connecting the PG-5G/ PG-5H interface cablesInstalling the DFK-3D panel kit Installing the Sub-PanelOperation panel Installing the Panel BracketClean and dry the installation location Connect the supplied sub-panel toInstalling the Line Filter Connecting the PG-5F extension cableConnecting Using a Single Extension Kit Connecting Using Two Extension KitsInstalling the VGS-1 Unit Insert the VGS-1 unit into the connector On the transceiverFrom the remaining cushions, select Cleaning MaintenanceService Service NoteTroubleshooting Problem Probable Cause Corrective ActionUP/DWN Specifications GeneralType M4 Type Receiver Transmitter