Kenwood TM-V71E Transmitting a 1750 Hz Tone, Reverse Function, Automatic Simplex Checker ASC

Page 38

Transmitting a 1750 Hz Tone

Most repeaters in Europe require that a transceiver transmit a 1750 Hz tone. By turning the 1750 Hz tone menu item ON, the transceiver will automatically transmit the 1750 Hz tone for 2 seconds whenever you transmit.

1Enter Menu mode and access Menu 402 (1750.HD) {page 20}.

2Set the tone to ON or OFF.

When set to ON, the 1750 Hz tone will transmit. When set to OFF, the tone will not be transmitted.

REVERSE FUNCTION

After setting a separate receive and transmit frequency, you can exchange these frequencies using the Reverse function. This allows you to manually check the strength of signals you receive directly from other stations, while using a repeater. If the station’s signal is strong, move to a simplex frequency to continue the contact and free up the repeater.

Press [REV] to turn the Reverse function ON or OFF.

• When the Reverse function is ON, the icon will appear on the display.

Note:

uIf the transmit frequency is outside the allowable transmit frequency range when using Reverse, pressing [PTT] will cause an error tone to sound and transmission will be inhibited.

uIf the receive frequency is outside the receive frequency range when using Reverse, an error tone will sound and Reverse will not operate.

uThe ARO (Automatic Repeater Offset) will not function when Reverse is ON.

uYou cannot switch Reverse ON or OFF while transmitting.

Automatic Simplex Checker (ASC)

While using a repeater, ASC periodically monitors the strength of signals you receive directly from the other stations. If the station’s signal is strong enough to allow direct contact without a repeater, the icon blinks.

Press [REV] (1s) to turn the ASC ON.

30

Image 38
Contents 144/440 MHz FM Dual Bander 144/430 MHz FM Dual BanderThank You FeaturesThis transceiver has the following main features Writing Conventions Followed in this ManualWhen Condensation Occurs Inside the Transceiver One or more of the following statements may be applicablePrecautions Contents Manual Dialing Automatic dialer Using Ctcss Ctcss Frequency IDUsing DCS DCS Code ID Dtmf Key Lock VGS-1 Optional Voice Guide & Storage UnitOptions Preparation Supplied AccessoriesMobile Installation Part Number QuantityPower Cable Connection Mobile OperationFixed Station Operation Replacing Fuses Located on the DC connectorSupplied DC power cable Fuse Location Fuse Current RatingAntenna Connection Front Panel Orientation Microphone Accessory ConnectionsExternal Speakers Getting Acquainted Front PanelPF1 REVLOW 0PF2Indicator Description DisplayAppears while accessing the Menu Rear Panel Sub-PanelMicrophone MC-59 Press the switch to switch the transceiver on Switching the Power ON/ OFFAdjusting the Volume Press the switch again to switch the transceiver OFFBand a left Band SEL control Band B right Band SEL control Adjusting the SquelchSelecting a Band Selecting Dual band mode/ single band Mode Selecting a frequency band Frequency rangesMemory Channel Mode Selecting an Operating modeVFO Mode When you finish speaking, release the PTT switch Call Channel ModePress Call to enter Call Channel mode TransmittingMenu Configuration Menu ModeMenu Access Press F, Tuning control to access the MenuANN.SPD DT.SPD MIC.LCK Character Entry Rotate the Tuning control to select your desired characterPress the Tuning control to set the selected character Repeat steps 2 and 3 to enter the remaining charactersMicrophone Keypad Character Entry Key Character Display with each press of the keySelecting an Offset Direction Repeater AccessOperating Through Repeaters Selecting an Offset Frequency Activating the Tone FunctionPress F, Tone Rotate the Tuning control to select your desired frequencySelecting a Tone Frequency FrequencyAutomatic Repeater Offset K and E Types Only Automatic Simplex Checker ASC Transmitting a 1750 Hz ToneReverse Function Tone Frequency ID Press F, Tone 1s to run the Tone Frequency ID scanParameter Simplex Odd-split Memory ChannelsSimplex & Repeater or ODD-SPLIT Memory CHANNEL? Call Channel Memory Simplex Storing Simplex and Standard Repeater FrequenciesStoring Odd-Split Repeater Frequencies Memory Recall Method Recalling a Memory ChannelCall Channel Memory Odd-Split Press the Tuning control to clear the Memory channel Turn the transceiver power OFFPress MR + Power on Clearing a Memory ChannelChannel Display FUnction Switching the Memory Name/ Frequency DisplayMemory-TO-VFO TRansfer Press F, VFOKey Name KEY KEY 1s While KEY +Programmable Memory PM Application Examples Press F, PM Storing Data in PM ChannelsRecalling PM Channels Press the Tuning control again to reset the PM channels PM Channel ResetPress F + Power on Auto PM Channel storeScan Scan Type Scan RangeSelecting a Scan Resume Method VFO ScanPress MR 1s Memory ScanLocking Out a Memory Channel To quit Memory Scan, press MR againMemory Group Link To quit Group Scan, press the Tuning control againGroup Scan Memory Group Channel RangePress VFO Setting Scan LimitsProgram Scan Using Program Scan To quit Program Scan, press VFO againCall Scan To quit MHz Scan, press the Tuning control againMHz Scan To quit Call Scan, press Call againUsing Ctcss Continuous Tone Coded Squelch System CtcssPress Enter again to complete the setting Ctcss FREQuency ID Press F, Tone 1sDigital Coded Squelch DCS Using DCSRotate the Tuning control to select your desired DCS code DCS Code DCS Code ID Dtmf Hold Dual Tone MULTI-FREQUENCY DtmfManual Dialing 1209 1336 1447 1633 697 770 852 941Automatic Dialer Storing a Dtmf Code in MemoryTransmitting Stored Dtmf Codes Selecting a Transmit SpeedDtmf Key Lock Selecting a Pause DurationWhat is EchoLink? Storing EchoLink memoryTransmitting EchoLink Memory EchoLink Sysop Mode OFF TM-V71 Setting Up EchoLink Sysop ModeEchoLink Sysop Mode on TM-V71 TxD RxDDisplay Brightness POWER-ON MessageAuxiliary Functions Auto Display BrightnessMicrophone Key Lock Key LockBacklight Color To turn Key Lock on or OFF, press F 1sProgrammable VFO Beep VolumeKey Beep Changing the Frequency Step Size Microphone Keys Programmable Function KeysTransceiver Front Panel Automatic Power OFF APO Frequency Direct EntrySquelch Hang Time Meter SquelchAdvanced Intercept Point AIP Speaker Mute Switching FM/AM ModeBeat Shift Mute Hang Time Selecting an Output PowerTIME-OUT Timer TOT Masking a Band External Speaker ConfigurationSetup Speaker Band OutputDisplay Partition Bar Channel No Weather Alert K Type Models OnlyWeather Channel Memory Name LocationPower On Password Enter your passwordOperation Announcement VGS-1 Optional Voice Guide & Storage UnitVoice Announcements Current frequency/codeAuto Voice Announcement Speed Voice Announcement VolumeVoice Announcement Language Voice Recorder Voice MemosConversation Recorder Playback Repeat Interval PlaybackPlayback Repeat Press Tone + Power on CROSS-BAND/ LOCKED-BAND Operation K Type Models onlyEntering your Repeater ID Repeater HoldRepeater ID Data Band Data terminal pinsPacket Operation Data Terminal SpeedSQC Output Setting PC Port SpeedWireless Operation K Type Models only PreparationOperation Dtmf Command Control OperationTransceiver Reset Menu Mode Options Using the MCP-2A SoftwareUsing the MCP-2A software, you can Memory control program MCP-2AInstalling the Sub-Panel Connecting the PG-5G/ PG-5H interface cablesInstalling the DFK-3D panel kit PC terminal pinsConnect the supplied sub-panel to Installing the Panel BracketClean and dry the installation location Operation panelConnecting Using Two Extension Kits Connecting the PG-5F extension cableConnecting Using a Single Extension Kit Installing the Line FilterFrom the remaining cushions, select Installing the VGS-1 UnitInsert the VGS-1 unit into the connector On the transceiver Service Note MaintenanceService CleaningUP/DWN TroubleshootingProblem Probable Cause Corrective Action Type M4 Type SpecificationsGeneral Transmitter Receiver