Star Trac 7600, 7700 manual DFR Code 800

Page 62

DFR Code 800 & 400

DFR CODE FLOWCHART: DEFINITIONS / MCB LED Blinks

DFR Flowchart For #: 800 & 400

Solution:

__ E1_______

Clean the under the

running belt and re-test

Note: If the problem continues replace the running belt.

__ E2_______

Replace MCB

Note: Make sure there

are no objects or

moveable parts that

may cause damage to

the wire.

___________________

Solution:

__ F1________

Replace MCB

Note: If AC LED is on and you get this error, replace the MCB.

__ F2________

Reconnect display cable and re-test

Note: If AC LED is not

on check the I/O

interface cable and connection. A speed command with the relay off can cause this error.

__ F3________

Replace I/O Interface cable (Display Cable)

__ F4________

Replace I/O Interface cable (Display Cable) and if the error still occurs replace the MCB

DFR Code = 800

Phase Over Current / 12 Blinks

Possible Causes:

(1)Worn running belt.

(2)Dirty running belt

(3)Faulty MCB.

Start

Turn the power off then back on at

the switch.

Engage Motor Test Mode.

Incline the unit to max elevation.

Stand at the highest point of the incline and push body weight back.

Does

the running belt slide smoothly across

deck?No

E1

Yes

Decline unit back to zero percent

in test mode.

Increase the speed to 2 MPH and

attempt to push the

belt back faster that the

commanded speed.

Does the running belt hold strong

to it’s commanded

speed?No

E2

E1

End

DFR Code = 400

Illegal Speed Command / 11 Blinks

Possible Causes:

(1)Pinched or damaged display cable.

(2)Bad wire connection to drive system

(3)Faulty MCB.

Start

Turn the power off then back on at

the switch.

Check AC LED on MCB to see if

it’s lit.

Does the AC LED off?

 

No

 

F1

Yes

Check I/O cable (display cable) at

the display and MCB for bad

connection.

Was the I/O cable

 

(display cable) making a

No

good connection?

F2

Yes

Check I/O cable (display cable)

pinched or damaged wires.

Was the I/O cable

(display cable) pinched or

damagd?No

YesF4

F3

End

60Service Manual – Treadmills: E-Series ￿ P-Series

Image 62
Contents Pro Tread AC 7600 Español EuropeAsia/Middle East Table of Contents Maintenance Mode Page Precautions Safety Electrical SafetyEquipment Placing Power Electricity ObjectivesEuropean Wire Wire ConfigurationsUSA Wire HOT Neutral GroundPower Cords Preventive Maintenance OverviewPreventive Maintenance Schedule Daily Weekly Monthly Running Belt Importance of Running Belt Maintenance Running Belt Do Not’sClean Belt Surface Cleaning a Running BeltCleaning Procedure Clean Between Deck & Belt Clean Sidebed CoversTools Required Running Belt TensionParts Required FrequencyRunning Belt Retension Procedure Be careful to ensure the Tail Roller does not Running Belt Alignment Roller do NOT’s Roller Care & MaintenanceCleaning Step Applying Wax to a Waxless Running BeltParts Required Step Maintenance Mode Engaging Maintenance ModeMaintenance Mode Keys Parameter Defaults Display ParametersNo Rail Stop Parameter Setting Definitions SPEED3 Check with a Star Trac sales representative for definitions Maintenance Mode Test Modes Display TestCalibrate Scale Csafe Test Maintenance Mode Auto Calibration Auto-CalibrationLast Error List Definitions Last StatDFR’s Drive Fault Records DFR InformationSoftware Display UploadersSoftware Required on your PC Time RequiredTools Required Obtaining the Fisp and Latest Software Extracting Unzipping the Zip Files Connecting the USB Cable to the PC If a ‘Security Warning’ window appears Click ‘Run’ Uploading the Software into the Uploader Project Change PointReturn to Project Change Point Software MCB Set Up Procedure for Programming mode Uploading Software into the AC MCB with MCB UploaderPage Setting Back To Run Mode Uploading to the MCBPage Part Replacement Procedures Running Belt Tensioning Procedure Frequency Recommended Preventative MaintenanceStep When finished, remove the tape from the running belt Toll Free 714-669-1660 Tel Troubleshooting Table Of Troubleshooting DocumentsCheck Speed System and Check Motor System DFR Code 1000000, 100000 DFR Code DFR Code DFR Code 800 DFR Flowchart For # DFR Code 40, 20 DFR Remaining Codes Slipping Running Belt This page intentionally left blank Doc Rev B