Star Trac 7600, 7700 manual DFR Code 40, 20

Page 64

DFR Code 40, 20 & 10

DFR CODE FLOWCHART: DEFINITIONS / MCB LED Blinks

DFR Flowchart For #: 40, 20 & 10

Solution:

__ H1_______

Replace MCB

__ H2_______

Replace I/O cable

__ H3_______

Reinsert the phase

wires into the harness

connector.

Note: If the wire

continues to make a

bad connection replace

drive motor.

DFR Code = 40

Phase A Circuit Open / 7 Blinks

DFR Code = 20

Phase B Circuit Open / 6 Blinks

DFR Code = 10

Phase C Circuit Open / 5 Blinks

Possible Causes:

(1)Bad wire connection on drive motor.

(2)Open phase wire in drive motor.

(3)Faulty MCB.

Start

Turn the power off then back on at

the switch.

There is a relay on the MCB that will activate when turning the AC power on when unit is in operable condition.

Did the display beep with

out the relay switch No activating?

H1

Yes

Check I/O cable (display cable) for pinched or damaged wires.

Was the I/O cable

 

 

 

 

No

in good condition?

 

 

 

 

 

 

 

 

 

 

 

 

 

H2

 

 

 

 

 

 

Yes

 

 

 

 

Check the phase wires on the

drive motor for good connection in the motor harness connector, or for a damaged wire.

Was there a

 

damaged wire or

 

bad connection on the

 

phase wires

No

to harness

connector?

 

 

H1

Yes

 

H3

 

End

 

62Service Manual – Treadmills: E-Series ￿ P-Series

Image 64
Contents Pro Tread AC 7600 Asia/Middle East EuropeEspañol Table of Contents Maintenance Mode Page Precautions Safety Electrical SafetyEquipment Placing Power Electricity ObjectivesWire Configurations USA WireEuropean Wire HOT Neutral GroundPower Cords Preventive Maintenance OverviewPreventive Maintenance Schedule Daily Weekly Monthly Running Belt Importance of Running Belt Maintenance Running Belt Do Not’sCleaning a Running Belt Cleaning Procedure Clean Between Deck & BeltClean Belt Surface Clean Sidebed CoversRunning Belt Tension Parts RequiredTools Required FrequencyRunning Belt Retension Procedure Be careful to ensure the Tail Roller does not Running Belt Alignment Cleaning Roller Care & MaintenanceRoller do NOT’s Parts Required Applying Wax to a Waxless Running BeltStep Step Maintenance Mode Engaging Maintenance ModeMaintenance Mode Keys Parameter Defaults Display ParametersNo Rail Stop Parameter Setting Definitions SPEED3 Check with a Star Trac sales representative for definitions Maintenance Mode Test Modes Display TestCalibrate Scale Csafe Test Maintenance Mode Auto Calibration Auto-CalibrationLast Error List Definitions Last StatDFR’s Drive Fault Records DFR InformationSoftware Display UploadersTools Required Time RequiredSoftware Required on your PC Obtaining the Fisp and Latest Software Extracting Unzipping the Zip Files Connecting the USB Cable to the PC If a ‘Security Warning’ window appears Click ‘Run’ Uploading the Software into the Uploader Project Change PointReturn to Project Change Point Software MCB Set Up Procedure for Programming mode Uploading Software into the AC MCB with MCB UploaderPage Setting Back To Run Mode Uploading to the MCBPage Part Replacement Procedures Running Belt Tensioning Procedure Frequency Recommended Preventative MaintenanceStep When finished, remove the tape from the running belt Toll Free 714-669-1660 Tel Troubleshooting Table Of Troubleshooting DocumentsCheck Speed System and Check Motor System DFR Code 1000000, 100000 DFR Code DFR Code DFR Code 800 DFR Flowchart For # DFR Code 40, 20 DFR Remaining Codes Slipping Running Belt This page intentionally left blank Doc Rev B