Landice 8700 manual VDC Transformer Replacement Home Treadmills only

Page 40

40

12 VDC TRANSFORMER REPLACEMENT (HOME TREADMILLS ONLY)

Observe the proper polarity when installing a new DC power transformer. Catastrophic damage can occur to the upper display board electronics if the DC polarity is reversed.

1.If your DC transformer has color coded fast-on (push on) connectors: Blue - negative (-)

Red - positive (+)

2.If your DC transformer has non color coded fast-on (push on) connectors: Black Wire (smooth) - negative (-)

Black Wire (ribbed) - positive (+)

3.If your DC transformer has pin-type connectors:

Black Wire - negative (-)

Black Wire w/ White strip - positive (+)

4.If you are retrofitting a new style DC transformer (Fast-On) connectors to a treadmill equipped with (Pin - Type) connectors follow these instructions.

a.Snip the DC output wires six inches from the harness plug with a pair of diagonal cutters.

b.Snip the FAST-ON connectors from the new DC transformer.

c.Use solderless butt-type connectors to splice the wires together.

d.Use the information listed above to make sure the proper polarity is observed.

RELAY BOARD (SPRINT 4/PRG/SST CLOSED LOOP ONLY)

1.Remove Orange wire from P1. This wire connects Relay Board to MCB.

2.Remove Brown wire from P2. This wire connects Relay Board to MCB.

3.Remove Purple wire from V+. This wire connects Relay to MCB.

4.Remove two (2) Black wires from DC Transformer. These wires connect Relay Board to DC Transformer. Note: Wires coming from Transformer are hard wired.

5.Remove Clip for Red, Green, and Black wires. These wires connect Relay Board to Speed Sensor mounted on Drive Motor.

6.Remove Clip for Blue, Orange, Brown, Red, Black, and White wires. These wires connect to Elevation Motor.

7.Remove Clip with Red, Brown, Blue, Yellow, White , Black, and Green wires labeled Upper Harness. This connects the Relay Board to the Upper Display.

8.Remove Four screws and remove board.

9.Reverse to install.

UPPER DISPLAY BOARD

1.Remove control panel end caps from upright assembly.

2.Remove membrane panel and display board assembly by releasing Velcro.

3.Disconnect upper wire harness from display board.

4.Remove screws securing display to membrane panel.

5.Install new display board.

Image 40
Contents Series Installation IntroductionParts Identification Servicing Landice TreadmillsHow to Use this Manual Landice Warranty and Policies PartsService Labor Treadmill PartsRecommended tools for servicing Landice treadmills Important Operating Safety Instructions Grounding Instructions 200 250 Volt Treadmills 15 Amp dedicated line Settings Used In Home Standard MembraneSprint Membrane Production Time Frame8700 EP/PT Membrane Membrane8700 PT2 Membrane SST MembraneProgrammable Membrane Sprint FaceplateParts Identification Em brane Panel-SPRINT3/4 70190 Side FR AM E XL Comercial Motor PAN Components Commercial Lower Wiring Schematic LED light emitting diode configurations SCR lower board Page Home SST VFX, PRG VFX, Sprint VFX Closed Loop Speed Sensor 8700 SST, PRG and Sprint VFX Treadmill LED Lights on PWM LED light emitting diode configurations Relay Board 8700 SST, PRG and Sprint 3, NON VFX Treadmill Sprint 3 treadmills have push button controlsSprint Sprint 1 Lower Wiring Schematic Sprint 1&2 Upper Wiring Schematic Definitions Safety Lanyard Side Frame CoversIR Potentiometer Membrane PanelUpper Wire Harness TreadbeltUpper Display Board Uprights VFX SystemTesting Components VDC Power SupplyElevation Motor FaceplatePWM Motor Control SCR Motor ControlRelay Board Upper Display BoardCommon Symptoms Symptom Treadmill slows down when user steps onto treadbeltSymptom Treadmill speed is erratic and/or surges IR Potentiometer ADJUSTMENTS, PWM only = 9.3rpm = 8.0rpmRemoval and Replacement of Components Power Cord Line CordVDC Transformer Replacement Home Treadmills only Relay Board Sprint 4/PRG/SST Closed Loop onlyDrive Motor Brushes Unplug treadmillInstall new Elevation Motor Remove Elevation MotorTo Enter Diagnostic Mode To calibrate the potentiometerDeck REMOVAL/DECK Reversal UN Plug Treadmill Treadbelt Unplug TreadmillTake Up Roller/ Rear Roller Drive Roller/Front Roller Noises Page Visual Clues Drive MotorsElectronic Boards Elevation MotorVoltage Tests Diagnostic Guide Error CodesSeries Treadmill Configuration Mode Treadbelt TRACKING, Tensioning and Maintenance Treadbelt TrackingTreadbelt Tensioning Drive Belt Tensioning Unplug TreadmillYES Drive motor is good. Proceed to Step YES Button Code Prog Enter Pause Start Display Fast Slow DownYES Elevation Potentiometer Calibration Series Home Treadmill Symptom Symptom Any found? Is speed control wiring OK?Is it out of position? Any found?Is the motor wiring OK? UP Down Clockwise Sprint 8700 PRG 8700 SST Page BELT-RELAY Sprint Symptom Applies to Sprint 2 Only Treadmill is switched on? Applies to Sprint 2 Only See Sprint 2 Wiring Schematic for Speed POT Settings Elevation system will need to Tracking and Tensioning Check Drive Belt tension Recommended Maintenance Make Sure Treadmill is LevelDrive Roller Alignment ExampleWhen to lubricate How to lubricateService CHECK-LIST Institutional drive motor maintenanceIndex 5V LED Drive Motor Brushes LED Lights Safety Lanyard Uprights Frame