Institutional drive motor maintenance

Yearly Institutional Maintenance: Replace the Drive Motor Brushes.

Failure to do so will result in premature Drive Motor failure.

1.Unplug Treadmill.

2.Remove Motor Brush caps (2).

3.Remove Motor Brushes and inspect. They should be replaced if 1/4 inch or less. Inspect motor Commutator for wear (Black-scoring present on copper segments) Try to dress out (clean up) Commutator with a Commutator stone or emery cloth.

4.When you reinstall motor brushes make sure the brush does not bind up in its holder. The motor brush must move freely the full length with zero resistance. If resistance is present you must carefully dress out the brush until the correct tolerance is achieved.

Motor brushes should be checked every 6 months on institutional treadmills and after 6 years on home units.

SERVICE CHECK-LIST

Check Treadbelt tension and tracking

Wipe underneath treadbelt

Lubricate Treadbelt

Check drive belt tension

Check motor brushes and commutator

Vacuum under motor hood

Vacuum around and under treadmill

Index

Description

Page Number

Image 80
Contents Series Installation IntroductionParts Identification Servicing Landice TreadmillsHow to Use this Manual Landice Warranty and Policies PartsService Labor Treadmill PartsRecommended tools for servicing Landice treadmills Important Operating Safety Instructions Grounding Instructions 200 250 Volt Treadmills 15 Amp dedicated line Settings Used In Home Standard MembraneSprint Membrane Production Time Frame8700 EP/PT Membrane Membrane8700 PT2 Membrane SST MembraneProgrammable Membrane Sprint FaceplateParts Identification Em brane Panel-SPRINT3/4 70190 Side FR AM E XL Comercial Motor PAN Components Commercial Lower Wiring Schematic LED light emitting diode configurations SCR lower board Page Home SST VFX, PRG VFX, Sprint VFX Closed Loop Speed Sensor 8700 SST, PRG and Sprint VFX Treadmill LED Lights on PWM LED light emitting diode configurations Relay Board 8700 SST, PRG and Sprint 3, NON VFX Treadmill Sprint 3 treadmills have push button controlsSprint Sprint 1 Lower Wiring Schematic Sprint 1&2 Upper Wiring Schematic Definitions Safety Lanyard Side Frame CoversIR Potentiometer Membrane PanelUpper Wire Harness TreadbeltUpper Display Board Uprights VFX SystemTesting Components VDC Power SupplyElevation Motor FaceplatePWM Motor Control SCR Motor ControlRelay Board Upper Display BoardCommon Symptoms Symptom Treadmill slows down when user steps onto treadbeltSymptom Treadmill speed is erratic and/or surges IR Potentiometer ADJUSTMENTS, PWM only = 9.3rpm = 8.0rpmRemoval and Replacement of Components Power Cord Line CordVDC Transformer Replacement Home Treadmills only Relay Board Sprint 4/PRG/SST Closed Loop onlyDrive Motor Brushes Unplug treadmillInstall new Elevation Motor Remove Elevation MotorTo Enter Diagnostic Mode To calibrate the potentiometerTake Up Roller/ Rear Roller Treadbelt Unplug TreadmillDeck REMOVAL/DECK Reversal UN Plug Treadmill Drive Roller/Front Roller Noises Page Visual Clues Drive MotorsElectronic Boards Elevation MotorVoltage Tests Diagnostic Guide Error CodesSeries Treadmill Configuration Mode Treadbelt TRACKING, Tensioning and Maintenance Treadbelt TrackingTreadbelt Tensioning Drive Belt Tensioning Unplug TreadmillYES Drive motor is good. Proceed to Step YES Button Code Prog Enter Pause Start Display Fast Slow DownYES Elevation Potentiometer Calibration Series Home Treadmill Symptom Symptom Any found? Is speed control wiring OK?Is it out of position? Any found?Is the motor wiring OK? UP Down Clockwise Sprint 8700 PRG 8700 SST Page BELT-RELAY Sprint Symptom Applies to Sprint 2 Only Treadmill is switched on? Applies to Sprint 2 Only See Sprint 2 Wiring Schematic for Speed POT Settings Elevation system will need to Tracking and Tensioning Check Drive Belt tension Recommended Maintenance Make Sure Treadmill is LevelDrive Roller Alignment ExampleWhen to lubricate How to lubricateIndex Institutional drive motor maintenanceService CHECK-LIST 5V LED Drive Motor Brushes LED Lights Safety Lanyard Uprights Frame