70
SYMPTOM
Upper Display does not light up.
Check position of Safety Key.*
YES |
|
|
|
| NO | AC |
|
Check for 120 VAC | 1. Check fuse on | ||
between points |
|
| motor control |
13 and 14 on |
|
| board, |
terminal |
|
| replace if |
block. |
|
| necessary |
YES |
|
| A. Check 20 |
|
|
| amp |
|
|
| fuse |
|
|
| (Mounted to motor pan) * |
|
|
| 2. Check for loose |
|
|
| connections |
|
|
| on terminal |
|
|
| block,damaged |
|
|
| line |
|
|
| cord or wall |
|
|
| outlet for |
|
|
| voltage. |
|
|
| |
Check for 9 VDC | NO | DC | 1. Check that |
between points |
|
| all |
|
|
| connections |
5 and 6 on |
|
| on terminal |
terminal |
|
| block are |
block. |
|
| tight. |
6 and 7 on |
|
|
|
terminal |
|
|
|
block. * |
|
|
|
YES |
|
| 2. Replace 9 VDC |
|
|
| power supply. |
|
|
| |
Check for 9 VDC | NO | DC | Check |
between pins 1 |
|
| connections |
|
|
| between |
and 2 on display |
|
| upper board |
board connector |
|
| and lower |
(Red and |
|
| components |
Green wires). |
|
| (wiring |
|
|
| harness) |
YES |
|
|
|
|
|
|
|
Replace |
|
|
|
display |
|
|
|
board. |
|
|
|
(#70130 Sprint 1/ |
|
|
|
|
|
|