Diamondback 1150Er, 1150Rb, 1150Ub Constant Power MET Program, Adjusting Heart Rate Percentage

Page 30

Workout Programs

for 4 seconds. If no pulse is detected, the message window will flash a message “CHECK YOUR PULSE”. Make sure your heart rate device is properly operated.

Once the program is started, the message window will display the workout data of “Time, Intensity Level, Calories and SPM”.

Press “SELECT” key to switch the display to “Floor per minute, Floors, Watt & % Heart Rate”.

Adjusting Heart Rate Percentage

User may press “UP/DOWN” key to adjust the Heart Rate Per- centage from 55% to 90% during anytime of the program.

Each time the “UP/DOWN” key is pressed,the message window will display “PERCENT HR = XX” and adjust it accordingly. When the adjustment is over it will resume to display the workout data.

Fewer adjustments are recommended for a better result.

Pause, Stop or Save

See Console operation tips section for details, page 15.

Enter another program during HR Interval program

User may enter another program during HR Training program by pressing another program key. If another program key is pressed during this time, the message display will scroll “PRESS ENTER TO ADJUST OR START TO BEGIN”. (Same as its program setting mode)

o User could press “ENTER” to enter this program setting mode or Press START key to start this program right away.

o If neither “ENTER” nor “START” key is pressed in 15 sec- onds, it will then resume back to HR Training program and continue workout.

o If another program is entered and started, the program time will continue to count down from previous program time and the workout data will be carried over to the next program.

28Ending the Program

Program end

When the selected program time is up, there will be a beep to signifying the end of this program.

The message window will scroll a messages ”PROGRAM ENDED. TOTAL TIME, FLOORS, CALORIES ARE:” Then the total workout data of “Time, Distance and Calories” will be displayed for 5 seconds.

After 5 seconds, it will scroll a message “SAVE YOUR PROGRAM OR PRESS START TO RE-START.” User could stop, re-start or save this program during this period of time, see below for details.

If no key is pressed, it will back to scroll a message “PROGRAM ENDED. TOTAL TIME, FLOORS, CALORIES ARE:” This sequence will be repeated for 30 seconds, and the console will be reset.

Stop this program

To stop this program, simply press “STOP” key once or stop ped- aling. The console will be reset to idle mode. No workout data will be saved for next workout.

Re-start this program

To Re-start this program, press “START” key once during this 30 seconds period. This program will be re-started. Time, Distance and Calories will be continued accumulating.

Save this program

To save this program, see USER 1 & USER 2 program page for de- tails.

After the program is saved, the message window will resume to display ”PROGRAM ENDED. TOTAL TIME, DISTANCE, CAL- ORIES ARE:” until another key is pressed or 30 seconds is up.

Enter another program

User may enter another program during program ending by pressing another program key, same as entering another program during the program-executing mode, except the time adjustment. User may adjust the program time or accept the default value 30 minutes as new program time.

CONSTANT POWER (MET) PROGRAM

This program is for 1150Ub, 1150Rb and 1150Er only

The Constant power program allows your equipment to be electroni- cally controlled to deliver a specific work rate. As the pedal rate falls, the brake is increasing resistance proportionally. There are 20 levels of MET level adjustments.

Getting Started

The 1150 Series units are self-generating. Begin pedaling to initialize the unit and enter the programming cycle. Be sure to include a warm- up and cool-down period as part of your workout.

Beginning the Program

Continue to pedal. The message window will scroll a message “SELECT A PROGRAM”. Press MET program key to enter this program.

Accepting Default values or Entering the program setting mode When the MET key is pressed, the message window will scroll a message “PRESS ENTER TO ADJUST OR START TO BEGIN”.

Press “START/Resume” key to accept current default values and begin MET program workout.

Or press “ENTER” key to enter program-setting mode. The mes- sage display will bring you through the program setting step by step as below:

Entering Age

4.If ENTER key is pressed, the message window will scroll, “AD- JUST AGE AND ENTER TO ACCEPT”. Then the “AGE = XX” will be blinking.

5.User may press “UP/DOWN” key to adjust the age.

6.After age adjustment, then press “ENTER” key to accept.

Entering Weight

4.If ENTER Key is pressed, the message window will scroll, “AD- JUST WEIGHT AND ENTER TO ACCEPT”. Then the “WEIGHT = XXX LB” will be blinking.

5.User may press “UP/DOWN” key to adjust the weight.

6.After the weight adjustment, then press “ENTER” key to ac- cept.

1 1 5 0 S E R I E S O W N E R’S M A N U A L

Image 30
Contents E R I E S To Activate Warranty Purchaser’s Reference InformationTable of Contents Ntroduction Safety Instructions & Warnings R N I N G to Reduce Risk of Injury to Yourself or Others1150Ub Assembly Drawing 1150Ub Assembly Instructions 1150Rb Assembly Drawing 1150Rb Assembly Instructions Rear Stabilizer Bar AssemblySeat Frame Assembly 1150St Assembly Drawing 1150St Assembly Instructions Handrail AssemblyWaterbottle 1150Er Assembly Drawing 1150Er Assembly Instructions Transportation Wheel Assembly1150Ub/Rb Series Operation & Comfort TipsGeneral 1150 Series Tips 1150 ErWorkout Guidelines Good health is an exercise in common senseHeart rate is an important key to your exercise Get a smart start on exercising Maximum Heart Rate & Training ZoneQuantity & Quality = 85% = 60%Pulse Hand Grips Standard Heart Rate MonitoringConsole Chest Strap StandardIntensity level definitions L10L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 Dot Matrix window Console LayoutProgram key Alphanumeric Message windowManual Program Workout ProgramsQuick Start Program Getting StartedEntering Program Time Entering WeightRandom Program Enter another program during Manual programEntering Program Intensity Level Enter another program during Random programFatburner Program Program ProfileEnter another program during Fatburner program Interval Program Enter another program during Interval programStrength Program Target Heart Rate Program Enter another program during Strength programEntering Target Heart Rate Adjusting Target Heart RateHeart Rate Interval Program Enter another program during Target Heart Rate programEntering Lower HR Goal Entering Upper HR GoalEnter another program during HR Interval program Heart Rate Training Program This program is for 1150St onlyConstant Power MET Program Adjusting Heart Rate PercentageTo Save a program into User 1 or User Adjusting MET LevelUser 1 & User 2 Program Entering MET LevelMaintenance Domestic Warranty Information IMPORTANT! IMPORTANT! IMPORTANT! Important 22-11-150