VDO Cyclecomputing Z3 PC-LINK Trip MAX, „AVG Climb, „TRIP Data ?RESET?, MAX Climb, Alti Down

Page 35

EN

Note: The minimum altitude change for the correct distance measure- ment must be 1 m

11.3.3. ¬ £ TRIP MAX = maximum altitude of the actual trip

Display

¥

TRIP MAX

Reset: 3 sec.

TRIP DATA ?RESET?

 

TRIP DATA ?RESET? <<?RESET?>> flashing

 

TRIP DATA RESET DONE

This resets all data of the functions marked by L Automatic return to operation mode for TRIP DIST

11.3.4. ¬ AVG CLIMB = average climb of the actual trip in percent

Display:

¥

„AVG CLIMB

Reset: 3 sec.

„TRIP DATA ?RESET?

 

TRIP DATA ?RESET? <<?RESET?>> flashing

 

TRIP DATA RESET DONE

This resets all data of the functions marked by L

Automatic return to operation mode for TRIP DIST

11.3.5.¬ MAX CLIMB = maximum climb of the actual trip in percent

Display

¥

MAX CLIMB

Reset: 3 sec.

TRIP DATA ?RESET?

 

TRIP DATA ?RESET? <<?RESET?>> flashing

 

TRIP DATA RESET DONE

This resets all data of the functions marked by L

Automatic return to operation mode for TRIP DIST

11.3.6.¬ £ TOTAL UP = total uphill altitude gain Bike 1 and Bike 2

Display

¥

„Tot 1/2 HM UP“ (walk mode TOTAL UP)

11.3.7. ¬

£ ALTI MAX = maximum altitude Bike 1 and Bike 2

Display

¥

„Total Max 1/2“ (walk mode ALTI MAX)

11.3.8.¬ £ ALTI DOWN = downhill altitude loss of the actual trip

Display

¥

ALTI DOWN

Reset: 3 sec.

TRIP DATA ?RESET?

 

TRIP DATA ?RESET? <<?RESET?>> flashing

 

TRIP DATA RESET DONE

This resets all data of the functions marked by L

Automatic return to operation mode for TRIP DIST

11.3.9. ¬ DIST DOWN = downhill distance of the actual trip

Display

¥

DIST DOWN

Reset: 3 sec.

TRIP DATA ?RESET?

 

TRIP DATA ?RESET? <<?RESET?>> flashing

 

TRIP DATA RESET DONE

This resets all data of the functions marked by L Automatic return to operation mode for TRIP DIST

Note: The minimum altitude change for the correct distance measure- ment must be 1 m

26

This resets all data of the functions marked by L.

Image 35
Contents VDO Series Z My Settings Picturebook P02 P03 P04/05 P06 P07 P08 P09 WS in mm / inch P11 P01 P01 page 1 in the picture book CongratulationsCable ties Optional extension set VDO cadence transmitter Initial operation, AC-button Language selection Personal settings with manual max. pulse entryPermanent functions in the display Selecting the operation mode Bike mode or walk modeLap timer Stopwatch Getting StartedControl System Operation Guarantee Conditions Technical Specifications GeneralFunctions Press button ç for 3 seconds To go to setting modeMiddle BAR DisplayDesignation Extension Options & AccessoriesPlace the pulse transmitter just below your chest and guide Handlebar holderSpeed transmitter and magnet P07 Putting on the PULSE-CHEST Belt P08Age appears Range of the pulse-chest belt transmitter = 0.90 mInitial OPERATION, AC-BUTTON P09-2 Language SelectionInitial Operation Pulse Transmitter Pulse PairingSpeed Pairing Cadence PairingAlarm SET Setting the LanguageSetting Time & Date Setting the ALARM, Alarm ClockSET Done Wheelsize SET… SET Size ?CONTINUE? ?SET OK?‚ ODO Bike 1/2 Next DIGIT? Setting Total KilometersBike Check / Service Interval Odometer SETSET SEX ?CONTINUE? SET Weight ?CONTINUE?Person Data SET SET AGE ?CONTINUE?Manual Entry of Pulse Limit Values Pulse Limit SettingsPulse Limit ?SET? ‚ Auto Limit 1 HIGH…LOWSelect Training Program SET Recovery Pulse MeasurementRecovery SET Measuring the Recovery PULSE/RECOVERY Time„SITTING POS Select Power Calc SET‚ Power Calc SET Done Bike Type SelectHome Alti ?SET OK? Setting the Actual AltitudeAnnual Uphill Altitude Gain Bike 1 and Bike 2 and Walk Mode Home Alti SET ‚ Total Time Reset DONE? Trip Data ?RESET? Trip Data Reset Done Reset Total Ride Time‚ Navigator Reset Done Resetting the Total Distance Meter‚ Odototal Reset Done Resetting the NavigatorCenter BAR Trip Data Reset Done LPermanent Functions HeaderMAX Climb „TRIP Data ?RESET?Trip MAX „AVG ClimbRide Time ‚ Trip Data Reset DoneMAX Down Trip DistanceCAD AVG MAX SpeedOption only with Cadence Extension CadenceStopwatch ODO BikeOdototal Time BikePulse MAX % LAP RECAVG Pulse MAX PulseBackward Selecting Navigator ModeCalorie Navigator SET‚ Navigator ?SET OK? Navigator ?RESET?Navigator Reset Done ‚ „NAVIGATOR Next DigitTimer ?SET? Timer SettingsTimer ?SELECT? LAP Timer ?SELECT?‚ SET Minutes ?CONTINUE? ‚ Timer 1+2 SET DoneLAP-TIMER Countdown ?SET?13.2 Beginning of the recording Start the recording 4sec Training with Timer 1 / Timer 2 / Timer 1+2Training with the Stopwatch Beginning of the recording Start the recording 4sec Combination timer 1+2Training with the Countdown Timer Lap time Average pulse during the lap Training with the LAP TimerLap number and time of the lap Training PrerequisiteBar Manual delete of training data is not possibleSelection of the Recording Interval Transferring Data to Your PC P11PC Link Select On the transmitter Check the batteryFor Wake UP Description special caseNo speed display Chest belt Belt Check the batterySpeed signal Receiving cadence signalsService yourself Personal maximum pulse Timer has not been startedIs in the set training ranges Start timer InstalledCycle Parts GmbH, Große Ahlmühle 33, D-76865 Rohrbach Guarantee ConditionsTechnical Specifications .-641/W.. Page Смесва с други отпадъци на работното място FIN  !$!! 7f6524j6.-64%0+.-6410+%0 Page SLO EU-Konformitätserklärung EU-Declaration of Conformity USA CDN USA CDN VDO Series Z