Cateye EC-37OO operating instructions Aerobic power measurement

Page 17

1

Aerobic power measurement (1)

Select the Aerobic Power

• For program selection see the Starting up section page 18.

Test Result Display,

Measurement Program

4 Cool Down

 

 

 

ml/kg·min

 

 

MOU

 

 

PFL

The buzzer sounds ten minutes later and the test result is dis- played on the LCD, and also printed out. The program then enters the 5 minute cool down phase and the COOL symbol lights up, however the LCD still displays the test result. Only the calorie consumption data on LCD panel will be updated if you keep pedaling.

2

Input Conditions

PLL

AGE

TEST

WT lb

TIME

Input your age, pulse limit, weight and sex. The initial display prior to input is as in the drawing. The numeric for age is blink- ing.

Initial

Value

Setting Range

Age

40

10~ 99

Pulse Limit

160 bpm

80~ 200 bpm

Weight

130 lb

 

Sex

Male

 

• The pitch sound to adjust your cadence at 60 rpm (rings every

half second) is set "ON".

• There is no graphic display yet in the LCD.

• Press the

MODE button to change the blinking numeric.

• You can increase or decrease the blinking numeric by pressing

the

 

 

 

 

 

button.

 

 

 

 

 

TEST

ECkcal

watt

PWC

kg·m

COOL

TIME

5 End Program

Note: When the upper pulse limit alarm is activated

If the upper pulse limit alarm is activated while the elapsed time is within 4 minutes, making the buzzer beep and drop- ping the resistance to the minimum of 0.5 kg·m, the test result is not displayed. If the upper pulse limit alarm is acti- vated after the elapsed time exceeds 4 minutes, the result is

displayedbased on the progress up to that point. In this

case the result is distinguished from normal .results. by add- ing "=" to the printing data of the printer.

If the 5 minute cool down phase elapses or if you press the ADV button, the buzzer sounds and the program ends.

The LCD returns to the initial screen.

If you are completely finishing the exercise, be sure to turn the power off by the switch at the right side of the main unit.

3

Start Program

 

 

 

 

 

 

 

 

rpm

TM

 

 

 

 

 

min:sec

TEST

 

 

 

 

 

watt

 

 

 

 

 

 

 

 

 

 

 

kg·m

 

 

 

 

 

 

 

 

 

kg·m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIME

 

 

 

 

 

 

 

 

rpm

TM

 

 

 

 

 

min:sec

TEST

 

 

 

 

 

watt

 

 

 

 

 

 

 

 

 

 

 

kg·m

 

 

 

 

 

 

 

 

 

kg·m

TIME

• After setting your conditions, adapt the earlobe pulse sensor

and press ADV button to start program.

• After printing out the conditions the LCD changes as in the

drawing.

• The word "READY" will be displayed on LCD panel. Wait still

for one minute.

• After one minute has elapsed, the buzzer sounds and the pitch

sound begins. Then start pedaling according to the pitch sound.

Note: You can cancel the pitch sound by pressing the button. If the symbol is on the LCD, the pitch sound is ON, and if not pitch sound is OFF. Pressing the pitch sound button toggles ON/OFF.

The initial workload (pedal torque) is indicated in blinking dot in the graphic section of the LCD. One dot along the horizontal axis indicates 30 seconds, and one along the vertical axis 0.5 kg·m. At every 30 seconds, the row of dots will increase by one towards the right of the graphic display, with the last row blink- ing.

At the 4th and 7th minutes the pedal torque will increase de- pending on your pulse rate at that time. The increased torque of 2nd and 3rd stages will be indicated in dots time after time in the graphic part.

Sample print out

• Shows that the Aerobic Power Measurement program has been performed.

• Date of execution

• Name: Put down your name in the blank.

• Sex : M = Male, F = Female

• Age

• Weight (lb or kg)

• Upper limit pulse rate

• Elapsed time (minute): printed every 30 seconds

• Cadence

• Work rate (watt)

• Pulse rate

• Pulse rate chart

• One minute before exercise: shows the pulse rate at the rest.

• 1st stage

• 2nd stage

• 3rd stage

• Calorie consumption

• Maximum physical capacity (PWCmax): the greater, the better.

• Maximum Oxygen uptake (MOU): the greater, the better.

• 5 rank physical fitness level

24

25

Image 17
Contents Cateye ergociser How to Use This Manual Name of parts RightSide Main BodyImportant Safety Instructions Make sure all components are included in a package Lets assemble Installing the control unit Level Adjustment How to Adjust each partAdjusting Seat Position Adjusting Seat HeightUsing pulse sensor during exercise Installing the pulse sensorHandling the pulseearlobe sensor Use of sensor clipYour first ride Six programs of operation Using your Cateye Ergociser without a data card Page Purpose of Exercise Your strength level and training indexExercise Plan Exercise Frequency and TimeTraining Index Physical Fitness LevelAerobic power measurement Maximum Physical Work Capacity PWC max Physical Fitness Level PFL Test ProtocolMaximum Oxygen Uptake MOU Select the Automatic Training Program Input Conditions Automatic trainingStart Program Start / Warm Up Exercise Maintaining Target Pulse RateExerciseWattage at Constant Isopower constant load trainingSelect the Isopower Training Program Input Conditions Select Interval Training Program Input Conditions Interval trainingExercise End Exercise Cool DownSelect the Hill Profile Training Program Input Conditions Hill profile trainingSelect the Manual Training Program Input Conditions Manual trainingChange display panel Into write-in phase Setting your own training patternInput new training pattern Registerpattern new trainingHow to make a data card Page External computer control via an RS232C terminal Contents of Data Transmission from the EC-3700External computer control via an RS232C terminal Transmission FormatSetting the date Using chestbelt heart rate sensorInserting printer paper What to do when printer paper gets jammedPrinting mechanism Handling Troubleshooting and handling careTroubleshooting Warranty service Warranty service and partsSpecifications 0689221 E