Remove the three #8 x 3/4" Screws (12) and care- |
|
|
fully pivot the Hood (61) off. | 61 | 12 |
| ||
|
| |
Locate the Reed Switch (71) and the Magnet (50) |
|
|
on the left side of the Pulley (51). Turn the Pulley |
|
|
until the Magnet is aligned with the Reed Switch. |
|
|
Make sure that the gap between the Magnet and | 1/8 in. |
|
the Reed Switch is about 1/8 in. (3 mm). If neces- |
| |
sary, loosen the 3/4" Reed Switch Screw (15), | 71 | 50 |
move the Reed Switch slightly, and then retighten | ||
the Screw. Reattach the Hood (not shown), and run |
| 51 |
the treadmill for a few minutes to check for a cor- | Top |
|
rect speed reading. |
| |
| View |
|
PROBLEM: The incline of the treadmill does not change correctly
SOLUTION: a. With the key in the console, press one of the Incline buttons. While the incline is changing, re- move the key. After a few seconds,
PROBLEM: The walking belt slows when walked on
SOLUTION: a. Use only a
b. If the walking belt is overtightened, treadmill perfor- b mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG
THE POWER CORD. Using the hex key, turn both rear roller bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.
c. If the walking belt still slows when walked on, see the front cover of this manual.