Testing Shoe Ranges

Connect the reference resistor to the “Shoe Plate Cable” and the tab of the 3MCopper Foil Tape on the 3MShoes and Wrist Strap Tester 747 as show in the Figure 2.

3MCOPPER FOIL TAPE

3MSHOES AND WRIST

STRAP SENSOR

RSB

Figure 2 : Wrist Strap Test Set-Up

Testing Shoes Low Limits – Refer to Shoes Test Table

1.Select 10 MΩ position on the “Shoes High” switch.

2.Select 100 KΩ position on the “Shoes Low” switch.

3.Select Shoes position on the “Signal Out” switch.

4.Set reference resistor to 97 KΩ.

5.Press down on the “Touch Panel” and observe LED indicators and value displayed on LCD comparing to Shoes Test Table on the following page.

6.Set reference resistor to 103 KΩ.

7.Press down on the “Touch Panel” and observe LED indicators and value displayed on LCD comparing to Shoes Test Table on the following page.

8.Select 1 MΩ position on the “Shoes Low” switch.

9.Set reference resistor to 970 KΩ.

10.Press down on the “Touch Panel” and observe LED indicators and value displayed on LCD comparing to Shoes Test Table on the following page.

11.Set reference resistor to 1.03 MΩ.

12.Press down on the “Touch Panel” and observe LED indicators and value displayed on LCD comparing to Shoes Test Table on the following page.

13.Repeat test sequence using specified reference resistors as indicated in Shoes Test Table below for 10 MΩ, 35 MΩ and 100 MΩ positions.

26

Image 27
Contents 3M Shoes and Wrist Strap Tester Table of Contents Inspection IntroductionIntended Use Explanation of Safety Label Signal Words & SymbolsPage Product Outline OverviewLCD Indicators Back Side Side PanelsConnecting the ESD Shoe Testing Plate Preparation Before TestingShoes Power Preparation Installing and Replacing the Batteries AC Adapter Connection Turning Power On and OffTurning Power Off Power Saver FunctionWall Mounting TestingESD Shoe Testing with the 3M Shoes and Wrist Strap Tester ALL setting is described in .1, Open Collector OutputImportant Note Use single-conductor wrist straps only Open Collector Output External Output FunctionTest Result Output Settings Test Result Output TerminalInternal Circuit Open-Collector Output Shoe and Wrist Strap ALL SettingRS-232C Communications SpecificationsPC Connection Cable ConnectionsPC System Requirements Measurement Resistance Range 0 to 200.0 MΩ Measurement SectionBattery Replacement Indicator Maintenance & ServiceLCD can display the following error messages Error MessagesCleaning Testing ConsiderationsOperational Verification Test Testing Wrist Strap Ranges Equipment RequiredTest Set-Up Testing Wrist Low Limit Refer to Wrist Test Table Testing Wrist High Limits Refer to Wrist Test TableWrist Test Table Testing Shoes Low Limits Refer to Shoes Test Table Testing Shoe RangesCULus Statement Regulatory InformationShoe Test Table Weee StatementFCC Electronic Solutions Division Static Control Products